journal article·2011-08

A method for assessing force/work parameters for stickiness of unset resin-composites

Muhammad Kaleem, Julian D. Satterthwaite, David C. Watts

Dental Materials· Volume 27· Issue 8
Publisher page

Abstract

Objectives To evaluate the stickiness of unset resin-composites, at different speeds and temperatures, in terms of maximum probe separation-force (F(max)) and work-of-separation (W(s)). Materials and methods Eight commercial light-cured resin-composites were selected. Each material was placed in a cylindrical mold (φ=7 mm × 5 mm depth) held at 25 °C or 37 °C. The maximum force (F(max), N) and work probe separation (W(s), N mm) were measured by using a texture analyzer to register force/displacement. A flat-ended stainless-steel probe (φ=6mm) was mechanically lowered onto and into the surface of the unset sample. When a 'trigger' compressive force of 0.05 N was registered, data-acquisition commenced. Descent continued until a compressive force of 1N was reached, which was held constant for 1s. Then the probe was moved vertically upward at constant speed. This was varied over the range 2, 4, 6 and 8mm/s. The tensile force produced on the probe by the sticky resin-composite was plotted against displacement and the maximum value was identified (F(max)). W(s) was obtained as the integrated area. Data was analyzed by multivariate ANOVA and multiple pair wise comparisons was done by using a Tukey post hoc test to establish homogenous subsets (at p=0.05). Results F(max) and W(s) were taken as potential measures of stickiness. They ranged from 0.47 to 3.68 N and from 0.11 to 2.84 N mm, respectively. Multivariate ANOVA showed a strong interaction of withdrawal speed, temperature and materials on both F(max) and W(s) (p<0.001). Conclusion F(max) and W(s) are useful parameters for characterizing the handling-stickiness of resin-composite materials, additional to previously reported stickiness-strain or 'peak-height'. The resin-composites investigated could be differentiated, mostly showing increases in F(max) and W(s) stickiness with increased temperature and probe-withdrawal speed.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Epoxy Resin Curing Processes · Dental materials and restorations · Mechanical Behavior of Composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (12)

Show source-provided references
1. Recent trends in esthetic restorations for posterior teeth
2. Stickiness prior to setting of some light cured resin-composites10.1016/S0109-5641(02)00097-0 ↗
3. Packable composites: overview and technical considerations10.1111/j.1708-8240.1999.tb00405.x ↗
4. Consistency of resin composites for posterior use10.1016/S0109-5641(96)80045-5 ↗
5. Radiographic assessments of Class II resin composite restorations in a clinical study: baseline results
6. Microstructure of posterior restorations of composite resin after clinical wear
7. Efficacy of dentin-bonding agents in relation to application technique10.3109/00016358909167312 ↗
8. Avery adhesive test yields more performance data than traditional probe
9. Rheology of urethane dimethacrylate and diluent formulations10.1016/S0109-5641(99)00043-3 ↗
10. Influence of temperature on the visco-elastic properties of direct and indirect dental composite resins10.1016/j.dental.2007.06.025 ↗
11. Dynamics of wetting. Local contact angles10.1017/S0022112090001859 ↗
12. Effect of filler particle size and morphology on force/work parameters for stickiness of unset resin-composites10.1016/j.dental.2009.08.002 ↗