journal article·2011-04

Transient and residual stresses induced during the sintering of two dentin ceramics

G. Isgró, O. Addison, G.J.P. Fleming

Dental Materials· Volume 27· Issue 4
Publisher page

Abstract

Objectives To characterize the stress induced deformation of bi-axial flexure strength (BFS) test specimens during processing to provide an insight into sintering effects and associated BFS determination. Methods 40 Vitadur-Alpha and 80 IPS e.max Ceram disc-shaped specimens were condensed and a sintered on a silicon nitride refractory tray under controlled firing and cooling parameters. The mean of the maximum deflection (μm) and Ra values (μm) were determined using a high resolution profilometer and were related to the orientation of the measured surface within the furnace. BFS testing of the subsequent groups (n = 20) was performed and the data related to the measured deformation of the sintered specimens. A two-way analysis of variance (ANOVA) where factors were identified as surface state and firing orientation with post hoc Tukey's tests was complemented by pair-wise comparisons with a Student's t-test for each measurement (P < 0.05). Results The mean of the maximum deflection values and the mean BFS for Vitadur Alpha discs were not significantly influenced by firing orientation (P = 0.248 and P = 0.284, respectively). However, the Ra values were significantly different (P < 0.001). The two-way ANOVA revealed a significant impact on the mean of the maximum deflection measurements for surface state (P < 0.001) and firing orientation (P < 0.001) during sintering (P < 0.001). The mean Ra values were not significantly influenced. The BFS of sintered IPS e.max Ceram discs was sensitive to firing orientation (P < 0.001). Significance Conventional glass theory explains that residual thermal stress gradients induced during sintering can cause test specimen deformation which can alter the expected BFS data. The study demonstrates that variability such as firing orientation during sintering which is very rarely reported in the literature can have a significant impact on the reported BFS data and can confound its interpretation.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Advanced ceramic materials synthesis · Recycling and utilization of industrial and municipal waste in materials production

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (52)

Show source-provided references
1. Dentine-bonded all-ceramic crowns: current status10.14219/jada.archive.1998.0244 ↗
2. The effect of luting media on the fracture resistance of a flame sprayed all-ceramic crown10.1016/S0300-5712(01)00040-9 ↗
3. Fracture resistance of teeth restored with dentine bonded crowns: the effect of increased tooth preparation
4. Fracture resistance of teeth restored with dentine-bonded crowns
5. The effect of a layer of resin luting agent on the biaxial flexure strength of two all-ceramic systems10.1016/j.prosdent.2005.02.012 ↗
6. Structure–property relationships of dental porcelains used in jacket crowns10.1038/sj.bdj.4805381 ↗
7. Strength of a dental glass–ceramic after surface coating10.1016/0109-5641(93)90074-Z ↗
8. Clinically relevant approach to failure testing of all-ceramic restorations10.1016/S0022-3913(99)70103-4 ↗
9. Contact damage as a failure mode during in vitro testing10.1111/j.1532-849X.1996.tb00281.x ↗
10. Tensile stresses in glass–ceramic crowns: effect of flaws and cement voids
11. Ceramics in dentistry: historical roots and current perspectives10.1016/S0022-3913(96)90413-8 ↗
12. Fracture-surface analysis of dental ceramics10.1016/0022-3913(89)90075-9 ↗
13. Fractographic analyses of three ceramic whole crown restoration failures10.1016/j.dental.2005.01.006 ↗
14. Measurement of tensile strength of brittle materials10.1088/0508-3443/10/6/307 ↗
15. Measurement of tensile strength of dental restorative materials by use of a diametral compression test10.1177/00220345710500025401 ↗
16. An analysis of the diametral–compression test
17. The tensile and compressive strength of plaster and stone10.1111/j.1834-7819.1966.tb03803.x ↗
18. Biaxial and uniaxial data for statistical comparison of a ceramic's strength10.1111/j.1151-2916.1979.tb19117.x ↗
19. Influence of test method on failure stress of brittle materials10.1177/00220345900690120201 ↗
20. Effect of loading conditions on bi-axial flexure strength of dental cements10.1016/0109-5641(92)90063-I ↗
21. An assessment of the influence of mixing induced variability on the bi-axial flexure strength of dentine porcelain discs and the implications for laboratory testing of porcelain specimens10.1016/S0109-5641(99)00090-1 ↗
22. The mechanical strength and microstructure of all-ceramic crowns10.1016/0300-5712(87)90141-2 ↗
23. Fatigue strength of silicate glasses
24. Biaxial flexure tests for ceramics
25. Ball-on-ring test revisted10.1111/j.1151-2916.1989.tb07702.x ↗
26. Hornberger H. Strength microstructure relationships in a dental alumina glass composite. Ph.D. Thesis 1995, The University of Birmingham.
27. The influence of cements on the mechanical performance of dental ceramics
28. The in vitro clinical failure of all-ceramic crowns and the connector area of fixed partial dentures: the influence of interfacial surface roughness10.1016/j.jdent.2004.10.025 ↗
29. The influence of interfacial surface roughness on bilayered ceramic specimen performance10.1016/S0109-5641(03)00085-X ↗
30. The influence of clinically induced variability on the bi-axial fracture strength of aluminous core porcelain discs10.1016/S0300-5712(99)00036-6 ↗
31. Influence of contraction mismatch and cooling rate on flexural failure of PFM systems10.1177/00220345880670011201 ↗
32. Effect of firing temperature and water exposure on crack propagation in unglazed porcelain10.1177/00220345890680060401 ↗
33. The deformation and strength of a dental ceramic following resin-cement coating
34. Symmetrical bending of circular plates
35. IPS. e.max® Ceram Product profile Ivoclar-Vivadent AG, Schaan, Liechtenstein.
36. Porcelain dental art
37. Resin elasticity and the strengthening of all-ceramic restorations10.1177/154405910708600606 ↗
38. Resin strengthening of dental ceramics—the impact of surface texture and silane10.1016/j.jdent.2006.11.012 ↗
39. Stress induced deformation of a dental ceramic following adhesive cementation10.1177/0022034509354049 ↗
40. The impact of modifying alumina air abrasion parameters on the performance of a porcelain laminate restorative material10.1016/j.dental.2006.11.012 ↗
41. The influence of alumina abrasion and cement lute on the strength of a porcelain laminate veneering material10.1016/j.jdent.2003.08.004 ↗
42. The impact of hydrofluoric acid surface treatments on the performance of a porcelain laminate restorative material10.1016/j.dental.2006.03.002 ↗
43. Adhesive cementation and the strengthening of all-ceramic dental restorations10.1163/156856109X440119 ↗
44. The influence of cement lute and thermocycling on the strength of porcelain laminate veneer (PLV) surface preparations10.1016/S0109-5641(03)00105-2 ↗
45. Quantifying the strength of a resin-coated ceramic10.1177/154405910808700610 ↗
46. The influence of thermocycling on the longevity of porcelain laminate veneer (PLV) restorations10.1016/S0109-5641(02)00046-5 ↗
47. Adhesive luting of all-ceramic restorations—the impact of cementation variables and short term water storage on the strength of a feldspathic dental ceramic
48. Effect of heat treatment on microcrack healing behaviour of a machinable dental ceramic
49. The effects of thermal mismatch and fabrication procedures on the deflection of layered all-ceramic discs10.1016/j.dental.2004.09.001 ↗
50. High strength CAD/CAM-fabricated veneering material sintered to zirconia copings–a new fabrication mode for all-ceramic restorations10.1016/j.dental.2008.04.019 ↗
51. Fatigue and fracture properties of yttria partially stabilized zirconia crown systems10.1016/j.dental.2007.05.011 ↗
52. Initial versus final fracture of metal-free-crowns, analysed via acoustic emission10.1016/j.dental.2008.04.010 ↗