Peri-implantitis cleaning instrumentation influences the integrity of photoactive nanocoatings
Source abstract
Abstract
Objective To determine in vitro the loss of integrity caused on photocatalytic anatase coated implant surfaces by clinical instrumentation through changes in surface topography and loss of functionality. Methods Anatase-coated titanium discs were treated with diamond burs, polishers, plastic and metal hand instruments, air scaler and air flow devices. The pressure exerted through instrumentation was measured online. Surface topography was evaluated through scanning electron microscopy and contact profilometry, surface function through hydrophilization capacity upon UV-A activation. Results Treatment with diamond burs and instruments with metal tips resulted in an increase of roughness. Use of silicone polishers led to smoothening, which was more pronounced on the anatase surface. Plastic instruments, the air abrasive system and rubber cups left the surfaces intact. Functionality was partially lost on surfaces subjected to hand instruments and completely lost upon diamond burs and silicone polishers. Significance The integrity of functional nanocoatings depends on the applied instrumentation. Air flow device, rubber cup with polishing paste and plastic tipped instruments prevent damage on these nanosurfaces and may be preferably used when decontaminating anatase and other nanocoatings in a clinical setting.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Ocular Disorders and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (40)
Show source-provided references
1. The roles of titanium surface micro/nanotopography and wettability on the differential response of human osteoblast lineage cells10.1016/j.actbio.2012.12.002 ↗
2. A review on the wettability of dental implant surfaces II: biological and clinical aspects10.1016/j.actbio.2014.03.032 ↗
3. Effects of titanium surface topography on bone integration: a systematic review10.1111/j.1600-0501.2009.01775.x ↗
4. Infectious risks for oral implants: a review of the literature10.1034/j.1600-0501.2002.130101.x ↗
5. Definition and prevalence of peri-implant diseases10.1111/j.1600-051X.2008.01274.x ↗
6. The epidemiology of peri-implantitis10.1111/j.1600-0501.2012.02541.x ↗
7. Effectiveness of implant therapy analyzed in a Swedish population: early and late implant loss10.1177/0022034514563077 ↗
8. How do implant surface characteristics influence peri-implant disease10.1111/j.1600-051X.2010.01661.x ↗
9. Experimental peri-implant mucositis at different implant surfaces10.1111/jcpe.12240 ↗
10. The interaction of cells and bacteria with surfaces structured at the nanometre scale10.1016/j.actbio.2010.04.001 ↗
11. Effects of material properties on bacterial adhesion and biofilm formation10.1177/0022034515587690 ↗
12. Peri-implantitis10.1016/j.bjoms.2011.11.020 ↗
13. Periimplant diseases: where are we now? Consensus of the Seventh European Workshop on Periodontology10.1111/j.1600-051X.2010.01674.x ↗
14. The therapy of peri-implantitis: a systematic review10.11607/jomi.2014suppl.g5.3 ↗
15. Decontamination of titanium implant surface and re-osseointegration to treat peri-implantitis: a literature review
16. Combined surgical therapy of advanced peri-implantitis lesions with concomitant soft tissue volume augmentation. A case series10.1111/clr.12103 ↗
17. The treatment of uncoated and titanium nitride-coated abutments with different instruments
18. Effects of 10 cleaning instruments on four different implant surfaces
19. Photo-induced hydrophilicity enhances initial cell behavior and early bone apposition10.1111/j.1600-0501.2007.01509.x ↗
20. Multifunctional nature of UV-irradiated nanocrystalline anatase thin films for biomedical applications10.1016/j.actbio.2010.06.021 ↗
21. Early osseointegration to hydrophilic and hydrophobic implant surfaces in humans10.1111/j.1600-0501.2011.02172.x ↗
22. Potential of chemically modified hydrophilic surface characteristics to support tissue integration of titanium dental implants10.1002/jbm.b.31233 ↗
23. Nanostructures and hydrophilicity influence osseointegration: a biomechanical study in the rabbit tibia10.1111/clr.12213 ↗
24. Formation and photocatalytic decomposition of a pellicle on anatase surfaces10.1177/0022034511424901 ↗
25. Deposition of photocatalytic TiO2 layers by pulse magnetron sputtering and by plasma-activated evaporation10.1016/j.vacuum.2005.11.001 ↗
26. Crystalline anatase-rich titanium can reduce adherence of oral streptococci10.1080/08927014.2014.922962 ↗
27. The influence of surface modification on bacterial adhesion to titanium-based substrates10.1021/am507148n ↗
28. Differential adhesion of Streptococcus gordonii to anatase and rutile titanium dioxide surfaces with and without functionalization with chlorhexidine10.1002/jbm.a.32170 ↗
29. Influence of plaque biofilm removal on reestablishment of the biocompatibility of contaminated titanium surfaces10.1002/jbm.a.30628 ↗
30. The effect of UV-photofunctionalization on the time-related bioactivity of titanium and chromium–cobalt alloys10.1016/j.biomaterials.2009.04.048 ↗
31. Age-dependent degradation of the protein adsorption capacity of titanium10.1177/0022034509339567 ↗
32. Photocatalytically induced hydrophilicity influences bone remodelling at longer healing periods: a rabbit study10.1111/clr.12138 ↗
33. Use of confocal microscopy for quantification of plastic remnants on rough titanium after instrumentation and evaluation of efficacy of removal10.11607/jomi.3500 ↗
34. Titanium surface alterations following the use of different mechanical instruments: a systematic review10.1111/j.1600-0501.2011.02208.x ↗
35. The effects of mechanical instruments on contaminated titanium dental implant surfaces: a systematic review10.1111/clr.12224 ↗
36. Biomaterial-centered infection—microbial adhesion versus tissue integration? (reprinted from science, vol. 237, pg. 1588–1595, 1987)
37. The influence of abutment surface roughness on plaque accumulation and peri-implant mucositis10.1034/j.1600-0501.1996.070302.x ↗
38. Effects of various hygiene procedures on the surface characteristics of titanium abutments10.1902/jop.1996.67.3.229 ↗
39. Strategies of making TiO2 and ZnO visible light active10.1016/j.jhazmat.2009.05.064 ↗
40. Photocatalytic effects of reactively sputtered N-doped anatase upon irradiation at UV-A and UV-A/VIS threshold wavelengths10.1016/j.surfcoat.2015.03.045 ↗