A Prospective Study on the Clinical Performance of Polysiloxane Soft Liners: One-year Results
Source abstract
Abstract
OBJECTIVE: The aim of the present study was to evaluate the clinical performance of four denture soft liners up to 12 months. MATERIALS AND METHODS: Thirty-three edentulous patients who experienced difficulties when using hard denture bases because of changes in denture-supporting tissues were accepted for the study and randomly received Molloplast B, GC Reline Soft, Silagum Comfort, or Mollosil Plus relines. Performance of the materials was evaluated using nine criteria at 3, 6, and 12 months: physical integrity, surface detail, adhesion, color, odor, plaque accumulation, resilience, hygiene, and mucosal condition. A four-point categorized scale (1=poor, 2=fair, 3=good, 4=excellent) was used. Unscheduled maintenance events and the presence of fungal colonization were also recorded. RESULTS: The percentage of patients available at 3, 6, and 12 months were 91%, 91%, and 66%. Main reasons for dropouts and discontinuation were fractured dentures and patient dissatisfaction. At 6 months, 96% of the performance scores were good or excellent and the largest changes were observed for physical integrity, surface detail, color, and fungal colonization. Fungal colonization was the most commonly observed problem and was the only reason of failure at 12 months. CONCLUSIONS: The clinical performance of all soft liners was slightly impaired over the 12-month observation. Except for cases showing extensive fungal colonization, the observed changes in clinical performance did not necessitate remaking of the dentures. Mollosil Plus showed a performance comparable to that of Molloplast B, and the other materials had slightly lower performance especially in terms of fungal colonization.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. 1) Mack PJ. Denture soft lining materials: clinical indications. Aust Dent J 1989; 34: 454-458.10.1111/j.1834-7819.1989.tb00704.x ↗
2. 2) Attard NJ, David LA, Zarb GA. Immediate loading of implants with mandibular overdentures: One-year clinical results of a prospective study. Int J Prosthodont 2005;18: 463-470.
3. 3) Wright PS. Soft lining materials: their status and prospects. J Dent 1976; 4: 247-256.10.1016/S0300-5712(76)80001-2 ↗
4. 4) Wright PS. The success and failure of denture soft-lining materials in clinical use. J Dent 1984; 12: 319-327.10.1016/0300-5712(84)90090-3 ↗
5. 10.1016/0022-3913(94)90558-410.1016/0022-3913(94)90558-4 ↗
6. 10.1016/S0022-3913(83)80082-110.1016/S0022-3913(83)80082-1 ↗
7. 10.1016/0022-3913(83)90563-210.1016/0022-3913(83)90563-2 ↗
8. 8) Jepson NJ, McCabe JF, Storer R. The clinical serviceability of two permanent denture soft linings. Br Dent J 1994; 177: 11-16.10.1038/sj.bdj.4808489 ↗
9. 9) Braden M, Wright PS, Parker S. Soft lining materials—a review. Eur J Prosthodont Restor Dent 1995; 3: 163-174.
10. 10) Braden M. Polymeric Dental Materials, Springer-Verlag, Berlin, 1997, pp.125-137.10.1007/978-3-642-60537-6 ↗
11. 11) Garcia LT, Jones JD. Soft liners. Dent Clin North Am 2004; 48: 709-720.10.1016/j.cden.2004.03.001 ↗
12. 10.1016/S0300-5712(98)00022-010.1016/S0300-5712(98)00022-0 ↗
13. 13) Nikawa H, Jin C, Hamada T, Makihira S, Kumagai H, Murata H. Interactions between thermal cycled resilient denture lining materials, salivary and serum pellicles and Candida albicans in vitro. Part II. Effects on fungal colonization. J Oral Rehabil 2000; 27: 124-130.10.1046/j.1365-2842.2000.00485.x ↗
14. 14) Jokstad A, Bayne S, Blunck U, Tyas M, Wilson N. Quality of dental restorations. FDI Commission Project 2-955. Int Dent J 2001;51: 117-158.10.1002/j.1875-595X.2001.tb00832.x ↗
15. 15) Shim JS, Watts DC. An examination of the stress distribution in a soft-lined acrylic resin mandibular complete denture by finite element analysis. Int J Prosthodont 2000; 13: 19-24.
16. 16) Jordan DR, Nerad JA. An acute inflammatory reaction to silicone stents. Ophthal Plast Reconstr Surg 1987; 3: 147-150.10.1097/00002341-198703030-00006 ↗
17. 17) Davenport JC. An adverse reaction to a silicone rubber soft lining material. Report of a case. Br Dent J 1970; 128: 545-546.10.1038/sj.bdj.4802497 ↗
18. 10.4012/dmj.26.29610.4012/dmj.26.296 ↗
19. 19) Mutluay MM, Ruyter IE. Evaluation of bond strength of soft relining materials to denture base polymers. Dent Mater 2007; 23: 1373-1381.10.1016/j.dental.2006.11.014 ↗
20. 20) Kutay O, Bilgin T, Sakar O, Beyli M. Tensile bond strength of a soft lining with acrylic denture base resins. Eur J Prosthodont Restor Dent 1994; 2: 123-126.
21. 10.1016/S0142-9612(01)00253-810.1016/S0142-9612(01)00253-8 ↗
22. 10.1016/0109-5641(91)90035-W10.1016/0109-5641(91)90035-W ↗
23. 23) Wright PS, Clark P, Hardie JM. The prevalence and significance of yeasts in persons wearing complete dentures with soft-lining materials. J Dent Res 1985; 64: 122-125.10.1177/00220345850640020501 ↗
24. 10.1177/1045441199010001050110.1177/10454411990100010501 ↗
25. 10.1016/0300-5712(94)90165-110.1016/0300-5712(94)90165-1 ↗
26. 10.1016/S0300-5712(97)00034-110.1016/S0300-5712(97)00034-1 ↗
27. 10.1016/S0022-3913(97)70148-310.1016/S0022-3913(97)70148-3 ↗