The effect of different light curing units on Vickers microhardness and degree of conversion of flowable resin composites

Swe Zin AUNG, Tomohiro TAKAGAKI, Masaomi IKEDA, Kosuke NOZAKI, Michael F. BURROW, Ahmed ABDOU, Toru NIKAIDO, Junji TAGAMI

Dental Materials Journal· Volume 40· Issue 1

Abstract

This study aimed to assess the influence of different light curing units (LCUs) on the polymerization of various flowable resin composites. Three LCUs (Optilux 501, Elipar™ DeepCure-L LED and Bluephase®20i) and eight flowable resin composites: MI FIL Flow, Estelite Flow Quick, Estelite Universal Flow (medium), Estelite Universal Flow (super low), Beautifil Flow Plus, Clearfil Majesty ES Flow, Filtek Supreme Ultra flowable and TetricEvo Flow were tested. For Vickers microhardness (VHN) test and degree of conversion (DC), specimens were prepared and polymerized for 20 s. VHN test was performed at top surfaces (3 indentations) and DC for each specimen was measured using Fourier transform infrared (FT-IR) spectroscopy after 24 h dry storage in dark at 37˚C. The data were analyzed with 2-way ANOVA and t-test with Bonferroni correction. DC and hardness values showed a relationship between materials and LCUs. The curing efficacy of LCU type may depend on the material composition.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Endodontics and Root Canal Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University

Department of Operative Dentistry, Division of Oral Functional Sciences and Rehabilitation, School of Dentistry, Asahi University

Oral Prosthetic Engineering, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University

Department of Biofunction Research, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental Universit

Faculty of Dentistry, The University of Hong Kong, Prince Philip Dental Hospital

References (46)

Show source-provided references
1. 1) Rada RE. The versatility of flowable composites. Dent Today 1998; 17: 78-83.
2. 2) Baroudi K, Rodrigues JC. Flowable resin composites: a systematic review and clinical considerations. J Clin Diagn Res 2015; 9: 18-24.10.7860/JCDR/2015/12294.6129 ↗
3. 3) Payne JH. The marginal seal of Class II restorations: flowable composite resin compared to injectable glass ionomer. J Clin Pediatr Dent 1999; 23: 123-130.
4. 4) Imai A, Takamizawa T, Sugimura R, Tsujimoto A, Ishii R, Kawazu M, et al. Interrelation among the handling, mechanical, and wear properties of the newly developed flowable resin composites. J Mech Behav Biomed Mater 2019; 89: 72-80.10.1016/j.jmbbm.2018.09.019 ↗
5. 5) Irie M, Tjandrawinata R, Lihua E, Yamashiro T, Suzuki K. Flexural performance of flowable versus conventional light-cured composite resins in a long-term in vitro study. Dent Mater J 2008; 27: 300-309.10.4012/dmj.27.300 ↗
6. 6) Sumino N, Tsubota K, Takamizawa T, Shiratsuchi K, Miyazaki M, Latta MA. Comparison of the wear and flexural characteristics of flowable resin composites for posterior lesions. Acta Odontol Scand 2013; 71: 820-827.10.3109/00016357.2012.734405 ↗
7. 7) Jafarzadeh TS, Erfan M, Behroozibakhsh M, Fatemi M, Masaeli R, Rezaei Y, et al. Evaluation of polymerization efficacy in composite resins via FT-IR spectroscopy and Vickers microhardness test. J Dent Res Dent Clin Dent Prospects 2015; 9: 226-232.10.15171/joddd.2015.041 ↗
8. 8) Esmaeili B, Safarcherati H, Vaezi A. Hardness evaluation of composite resins cured with QTH and LED. J Dent Res Dent Clin Dent Prospects 2014; 8: 40-44.
9. 9) Catelan A, Mainardi Mdo C, Soares GP, de Lima AF, Ambrosano GM, Lima DA, et al. Effect of light curing protocol on the degree of conversion of composites. Acta Odontol Scand 2014; 72: 898-902.10.3109/00016357.2014.920108 ↗
10. 11) Ozturk B, Cobanoglu N, Cetin AR, Gunduz B. Conversion degrees of resin composites using different light sources. Eur J Dent 2013; 7: 102-109.
11. 12) Marovic D, Panduric V, Tarle Z, Ristic M, Sariri K, Demoli N, et al. Degree of conversion and microhardness of dental composite resin materials. J Mol Struct 2013; 1044: 299-302.10.1016/j.molstruc.2012.10.062 ↗
12. 13) Mayworm CD, Camargo SS Jr, Bastian FL. Influence of artificial saliva on abrasive wear and microhardness of dental composites filled with nanoparticles. J Dent 2008; 36: 703-710.10.1016/j.jdent.2008.05.001 ↗
13. 14) Sampaio CS, Atria PJ, Rueggeberg FA, Yamaguchi S, Giannini M, Coelho PG, et al. Effect of blue and violet light on polymerization shrinkage vectors of a CQ/TPO-containing composite. Dent Mater 2017; 33: 796-804.10.1016/j.dental.2017.04.010 ↗
14. 15) Santini A, Miletic V, Swift MD, Bradley M. Degree of conversion and microhardness of TPO-containing resin-based composites cured by polywave and monowave LED units. J Dent 2012; 40: 577-584.10.1016/j.jdent.2012.03.007 ↗
15. 16) Shimokawa C, Sullivan B, Turbino ML, Soares CJ, Price RB. Influence of emission spectrum and irradiance on light curing of resin-based. Oper Dent 2017; 42: 537-547.10.2341/16-349-L ↗
16. 17) Price RB, Labrie D, Rueggeberg FA, Sullivan B, Kostylev I, Fahey J. Correlation between the beam profile from a curing light and the microhardness of four resins. Dent Mater 2014; 30: 1345-1357.10.1016/j.dental.2014.10.001 ↗
17. 18) Ilie N, Hickel R, Watts DC. Spatial and cure-time distribution of dynamic-mechanical properties of a dimethacrylate nano-composite. Dent Mater 2009; 25: 411-418.10.1016/j.dental.2008.11.008 ↗
18. 19) Beun S, Bailly C, Devaux J, Leloup G. Rheological properties of flowable resin composites and pit and fissure sealants. Dent Mater 2008; 24: 548-555.10.1016/j.dental.2007.05.019 ↗
19. 20) Czasch P, Ilie N. In vitro comparison of mechanical properties and degree of cure of a self-adhesive and four novel flowable composites. J Adhes Dent 2013; 15: 229-236.
20. 21) Jager S, Balthazard R, Dahoun A, Mortier E. Filler content, surface microhardness, and rheological properties of various flowable resin composites. Oper Dent 2016; 41: 655-665.10.2341/16-031-L ↗
21. 22) Blackham JT, Vandewalle KS, Lien W. Properties of hybrid resin composite systems containing prepolymerized filler particles. Oper Dent 2009; 34: 697-702.10.2341/08-118-L ↗
22. 23) Leprince J, Palin WM, Mullier T, Devaux J, Vreven J, Leloup G. Investigating filler morphology and mechanical properties of new low-shrinkage resin composite types. J Oral Rehabil 2010; 37: 364-376.10.1111/j.1365-2842.2010.02066.x ↗
23. 24) Hahnel S, Dowling AH, El-Safty S, Fleming GJ. The influence of monomeric resin and filler characteristics on the performance of experimental resin-based composites (RBCs) derived from a commercial formulation. Dent Mater 2012; 28: 416-423.10.1016/j.dental.2011.11.016 ↗
24. 25) Mobarak E, Elsayad I, Ibrahim M, El-Badrawy W. Effect of LED light-curing on the relative hardness of tooth-colored restorative materials. Oper Dent 2009; 34: 65-71.10.2341/08-38 ↗
25. 26) Ferracane JL. Resin composite-state of the art. Dent Mater 2011; 27: 29-38.10.1016/j.dental.2010.10.020 ↗
26. 27) Abed YA, Sabry HA, Alrobeigy NA. Degree of conversion and surface hardness of bulk-fill composite versus incremental-fill composite. Tanta Dent J 2015; 12: 71-80.10.1016/j.tdj.2015.01.003 ↗
27. 28) Sideridou I, Tserki V, Papanastasiou G. Effect of chemical structure on the degree of conversion in light-cured dimethacrylate-based dental resins. Biomaterials 2002; 23: 1819-1829.10.1016/S0142-9612(01)00308-8 ↗
28. 29) Turssi CP, Ferracane JL, Vogel K. Filler features and their effects on wear and degree of conversion of particulate dental resin composites Biomaterials 2005; 26: 4932-4937.10.1016/j.biomaterials.2005.01.026 ↗
29. 30) Manhart J, Kunzelmann KH, Chen HY, Hickel R. Mechanical properties of new composite restorative materials. J Biomed Mater Res 2000; 53: 353-361.10.1002/1097-4636(2000)53:4<353::AID-JBM9>3.0.CO;2-B ↗
30. 31) Rode KM, Kawano Y, Turbino ML. Evaluation of curing light distance on resin composite microhardness and polymerization. Oper Dent 2007; 32: 571-578.10.2341/06-163 ↗
31. 32) Tassery H, de Donato P, Barrès O, Déjou J. In vitro assessment of polymerization procedures in class II restorations: Sealing, FTIR, and micro-hardness evaluations. J Adhes Dent 2001; 3: 247-255.
32. 33) Da Silva EM, Poskus LT, Guimarães JG, de Araújo Lima Barcellos A, Fellows CE. Influence of light polymerization modes on the degree of conversion and crosslink density of dental composites. J Mater Sci Mater Med 2008; 19: 1027-1032.10.1007/s10856-007-3220-5 ↗
33. 34) Mandikos MN, Mc Givney, Davis E, Bush PJ, Carter JM. A comparison of the wear resistance and hardness of indirect composite resins. J Prosthet Dent 2001; 85: 386-395.10.1067/mpr.2001.114267 ↗
34. 35) Da Silva EM, Almeida GS, Poskus LT, Guimarães JG. Relationship between the degree of conversion, solubility and salivary sorption of a hybrid and a nanofilled resin composite. J Appl Oral Sci 2008; 16: 161-166.10.1590/S1678-77572008000200015 ↗
35. 36) DeWald JP, Ferracane JL. A comparison of four modes of evaluating depth of cure of light-activated composites. J Dent Res 1987; 66: 727-730.10.1177/00220345870660030401 ↗
36. 37) Santos GB, Medeiros IS, Fellows CE, Muench A, Braga RR. Composite depth of cure obtained with QTH and LED units assessed by microhardness and micro-Raman spectroscopy. Oper Dent 2007; 32: 79-83.10.2341/06-26 ↗
37. 38) César PF, Miranda Jr WG, Braga RR. Influence of shade and storage time on flexural strength, flexural modulus, and hardness of composites used for indirect restorations. J Prosthet Dent 2001; 86: 289-296.10.1067/mpr.2001.114513 ↗
38. 39) Ferracane JL. Correlation between hardness and degree of conversion during the setting reaction of unfilled dental restorative resins. Dent Mater 1985; 1: 11-14.10.1016/S0109-5641(85)80058-0 ↗
39. 40) Neves AD, Discacciati JA, Orêfice RL, Jansen WC. Correlation between degree of conversion, microhardness and inorganic content in composites Pesqui Odontol Bras 2002; 16: 349-354.10.1590/S1517-74912002000400012 ↗
40. 41) Rahiotis C, Kakaboura A, Loukidis M, Vougiouklakis G. Curing efficiency of various types of light-curing units. Eur J Oral Sci 2004; 112: 89-94.10.1111/j.0909-8836.2004.00092.x ↗
41. 42) Jandt KD, Mills RW. A brief history of LED photopolymerization. Dent Mater 2013; 29: 605-617.10.1016/j.dental.2013.02.003 ↗
42. 43) Rueggeberg FA. State-of-the-art: dental photocuring —a review. Dent Mater 2011; 27: 39-52.10.1016/j.dental.2010.10.021 ↗
43. 44) Price RB, Felix CA, Andreou P. Third-generation vs a second-generation LED curing light: effect on Knoop microhardness. Compend Contin Educ Dent 2006; 27: 490-496.
44. 45) Leprince JG, Palin WM, Hadis MA, Devaux J, Leloup G. Progress in dimethacrylate-based dental composite technology and curing efficiency. Dent Mater 2013; 29: 139-156.10.1016/j.dental.2012.11.005 ↗
45. 46) Miletic V, Santini A. Micro-Raman spectroscopic analysis of the degree of conversion of composite resins containing different initiators cured by polywave or monowave LED units. J Dent 2012; 40: 106-113.10.1016/j.jdent.2011.10.018 ↗
46. 47) Neumann MG, Schmitt CC, Ferreira GC, Corrêa IC. The initiating radical yields and the efficiency of polymerization for various dental photoinitiators excited by different light curing units. Dent Mater 2006; 22: 576-584.10.1016/j.dental.2005.06.006 ↗