Nd:YVO4 laser groove treatment can improve the shear bond strength between dental PEEK and adhesive resin cement with an adhesive system
Source abstract
Abstract
The purpose of this study was to investigate the effect of various surface treatments on the shear bond strength between dental polyetheretherketone (PEEK) and adhesive resin cement. Two hundred and forty specimens were randomly classified into four groups: no treatment, sandblasted, sulfuric-acid-etched, and laser-grooved treatment. Each group was classified into two adhesive resin cement subgroups. Surface roughness, water contact angle, shear bond strength, and failure mode were measured; SEM and XPS results were obtained. The data were statistically analyzed using one-way or two-way analysis of variance and Tukey's honest significant difference test (α=0.05). Laser-grooved PEEK surface showed regular grooves and carbonization by thermal degradation; the surface roughness as well as water contact angle of were the highest in all groups. Shear bond strength values were significantly higher in the laser-groove-treated and sulfuric-acid-etched groups. Laser-groove-treated specimens showed cohesive failure. Laser-grooved treatment can improve shear bond strength between PEEK and adhesive resin cement.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Advanced Prosthodontics, Graduate School of Biomedical and Health Sciences, Hiroshima University
Department of Biomaterials, Graduate School of Biomedical and Health Sciences, Hiroshima University
References (38)
Show source-provided references
1. 1) Stawarczyk B, Jordan P, Schmidlin PR, Roos M, Eichberger M, Gernet W, et al. PEEK surface treatment effects on tensile bond strength to veneering resins. J Prosthet Dent 2014; 112: 1278-1288.10.1016/j.prosdent.2014.05.014 ↗
2. 2) Stawarczyk B, Thrun H, Eichberger M, Roos M, Edelhoff D, Schweiger J, et al. Effect of different surface pretreatments and adhesives on the load-bearing capacity of veneered 3-unit PEEK FDPs. J Prosthet Dent 2015; 114: 666-673.10.1016/j.prosdent.2015.06.006 ↗
3. 3) Katzer A, Marquardt H, Westendorf J, Wening JV, Foerster GV. Polyetheretherketone —Cytotoxicity and mutagenicity in vitro. Biomaterials 2002; 23: 1749-1759.10.1016/S0142-9612(01)00300-3 ↗
4. 4) Kurtz SM, Devine JN. PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials 2007; 28: 4845-4869.10.1016/j.biomaterials.2007.07.013 ↗
5. 5) Wang H, Xu M, Zhang W, Kwok DT, Jiang J, Wu Z, et al. Mechanical and biological characteristics of diamond-like carbon coated poly aryl-ether-ether-ketone. Biomaterials 2010; 31: 8181-8187.10.1016/j.biomaterials.2010.07.054 ↗
6. 6) Zhao Y, Wong HM, Wang W, Li P, Xu Z, Chong EYW, et al. Cytocompatibility, osseointegration, and bioactivity of three-dimensional porous and nanostructured network on polyetheretherketone. Biomaterials 2013; 34: 9264-9277.10.1016/j.biomaterials.2013.08.071 ↗
7. 7) Meningaud JP, Spahn F, Donsimoni JM. After titanium, PEEK? Rev Stomatol Chir Maxillofac 2012; 113: 407-410.10.1016/j.stomax.2011.12.016 ↗
8. 8) Santing HJ, Meijer HJ, Raghoebar GM, Özcan M. Fracture strength and failure mode of maxillary implant-supported provisional single crowns: A comparison of composite resin crowns fabricated directly over PEEK abutments and solid titanium abutments. Clin Implant Dent Relat Res 2012; 14: 882-889.10.1111/j.1708-8208.2010.00322.x ↗
9. 9) Wu X, Liu X, Wei J, Ma J, Deng F, Wei S. Nano-TiO2/PEEK bioactive composite as a bone substitute material: in vitro and in vivo studies. Int J Nanomedicine 2012; 7: 1215-1225.10.2147/IJN.S28101 ↗
10. 10) Lee WT, Koak JY, Lim YJ, Kim SK, Kwon HB, Kim MJ. Stress shielding and fatigue limits of poly-ether-ether-ketone dental implants. J Biomed Mater Res B Appl Biomater 2012; 100: 1044-1052.10.1002/jbm.b.32669 ↗
11. 11) Schwitalla A, Müller WD. PEEK dental implants: a review of the literature. J Oral Implantol 2013; 39: 743-749.10.1563/AAID-JOI-D-11-00002 ↗
12. 12) Stawarczyk B, Beuer F, Wimmer T, Jahn D, Sener B, Roos M, et al. Polyetheretherketone —A suitable material for fixed dental prostheses? J Biomed Mater Res B Appl Biomater 2013; 101: 1209-1216.10.1002/jbm.b.32932 ↗
13. 13) Najeeb S, Zafar MS, Khurshid Z, Siddiqui F. Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics. J Prosthodont Res 2016; 60: 12-19.10.1016/j.jpor.2015.10.001 ↗
14. 14) Ma R, Tang T. Current strategies to improve the bioactivity of PEEK. Int J Mol Sci 2014; 15: 5426-5445.10.3390/ijms15045426 ↗
15. 15) Oilo G. Bond strength testing: What does it mean? Int Dent J 1993; 43: 492-498.
16. 16) Ersu B, Yuzugullu B, Ruya Yazici A, Canay S. Surface roughness and bond strengths of glass-infiltrated alumina-ceramics prepared using various surface treatments. J Dent 2009; 37: 848-856.10.1016/j.jdent.2009.06.017 ↗
17. 17) Marshall SJ, Bayne SC, Baier R, Tomsia AP, Marshall GW. A review of adhesion science. Dent Mater 2010; 26: e11-e16.10.1016/j.dental.2009.11.157 ↗
18. 18) Schmidlin PR, Stawarczyk B, Wieland M, Attin T, Hämmerle CH, Fischer J. Effect of different surface pre-treatments and luting materials on shear bond strength to PEEK. Dent Mater 2010; 26: 553-559.10.1016/j.dental.2010.02.003 ↗
19. 19) Uhrenbacher J, Schmidlin PR, Keul C, Eichberger M, Roos M, Gernet W, et al. The effect of surface modification on the retention strength of polyetheretherketone crowns adhesively bonded to dentin abutments. J Prosthet Dent 2014; 112: 1489-1497.10.1016/j.prosdent.2014.05.010 ↗
20. 20) Zhou L, Qian Y, Zhu Y, Liu H, Gan K, Guo J. The effect of different surface treatments on the bond strength of PEEK composite materials. Dent Mater 2014; 30: e209-e215.10.1016/j.dental.2014.03.011 ↗
21. 21) Sproesser O, Schmidlin PR, Uhrenbacher J, Roos M, Gernet W, Stawarczyk B. Effect of sulfuric acid etching of polyetheretherketone on the shear bond strength to resin cements. J Adhes Dent 2014; 16: 465-472.
22. 22) Silthampitag P, Chaijareenont P, Tattakorn K, Banjongprasert C, Takahashi H, Arksornnukit M. Effect of surface pretreatments on resin composite bonging to PEEK. Dent Mater J 2016; 35: 668-674.10.4012/dmj.2015-349 ↗
23. 23) Kern M, Lehmann F. Influence of surface conditioning on bonding to polyetheretherketon (PEEK). Dent Mater 2012; 28: 1280-1283.10.1016/j.dental.2012.09.010 ↗
24. 24) Stawarczyk B, Bähr N, Beuer F, Wimmer T, Eichberger M, Gernet W, et al. Influence of plasma pretreatment on shear bond strength of self-adhesive resin cements to polyetheretherketone. Clin Oral Investig 2014; 18: 163-170.10.1007/s00784-013-0966-7 ↗
25. 25) Bötel F, Zimmermann T, Sütel M, Müller WD, Schwitalla AD. Influence of different low-pressure plasma process parameters on shear bond strength between veneering composites and PEEK materials. Dent Mater 2018; 34: e246-e254.10.1016/j.dental.2018.06.004 ↗
26. 26) Kazama-Koide M, Ohkuma K, Ogura H, Miyagawa Y. A new method for fabricating zirconia copings using a Nd:YVO4 nanosecond laser. Dent Mater J 2014; 33: 422-429.10.4012/dmj.2013-348 ↗
27. 27) Tsuka H, Morita K, Kato K, Kimura H, Abekura H, Hirata I, et al. Effect of laser groove treatment on shear bond strength of resin-based luting agent to polyetheretherketone (PEEK). J Prosthodont Res 2019; 63: 52-57.10.1016/j.jpor.2018.08.001 ↗
28. 28) Fuhrmann G, Steiner M, Freitag Wolf S, Kerm M. Resin bonding to three types of polyaryletherketones (PAEKs)-durability and influence of surface conditioning. Dent Mater 2014; 30: 357-363.10.1016/j.dental.2013.12.008 ↗
29. 29) Çulhaoğlu AK, Özkır SE, Şahin V, Yılmaz B, Kılıçarslan MA. Effect of various treatment modalities on surface characteristics and shear bond strengths of polyetheretherketone-based core materials. J Prosthodont 2020; 29: 136-141.10.1111/jopr.12702 ↗
30. 30) Tsuka H, Morita K, Kato K, Kawano H, Abekura H, Tsuga K. Evaluation of shear bond strength between PEEK and resin-based luting material. J Oral Biosci 2017; 59: 231-236.10.1016/j.job.2017.09.003 ↗
31. 31) Abe Y, Hiasa K, Hirata I, Okazaki Y, Nogami K, Mizumachi W, et al. Detection of synthetic RGDS(PO3H2)PA peptide adsorption using a titanium surface plasmon resonance biosensor. J Mater Sci Mater Med. 2011; 22: 657-661.10.1007/s10856-010-4222-2 ↗
32. 32) Stawarczyk B, Keul C, Beuer F, Roos M, Schmidlin PR. Tensile bond strength of veneering resins to PEEK: Impact of different adhesives. Dent Mater J 2013; 32: 441-448.10.4012/dmj.2013-011 ↗
33. 33) Keul C, Liebermann A, Schmidlin PR, Roos M, Sener B, Stawarczyk B. Influence of PEEK surface modification on the retention of two veneering resin composites. J Adhes Dent 2014; 16: 383-392.
34. 34) Rosentritt M, Preis V, Behr M, Sereno N, Kolbeck C. Shear bond strength between veneering composite and PEEK after different surface modifications. Clin Oral Investig 2015; 19: 739-744.10.1007/s00784-014-1294-2 ↗
35. 35) Tsujimoto A, Barkmeier WW, Takamizawa T, Wilwerding TM, Latta MA, Miyazaki M. Interfacial characteristics and bond durability of universal adhesive to various substrates. Oper Dent 2017; 42: E59-E70.10.2341/15-353-L ↗
36. 36) Caglar I, Ates SM, Yesil Duymus Z. An in vitro evaluation of the effect of various adhesives and surface treatments on bond strength of resin cement to polyetheretherketone. J Prosthodont 2019; 28: e342-e349.10.1111/jopr.12791 ↗
37. 37) Gumus HO, Kurtulus IL, Kuru E. Evaluation and comparison of the film thicknesses of six temporary cements before and after thermal cycling. Niger J Clin Pract 2018; 21: 1656-1661.10.4103/njcp.njcp_276_17 ↗
38. 38) Hallmann L, Mehl A, Sereno N, Hämmerle CHF. The improvement of adhesive properties of PEEK through different pre-treatments. Appl Surf Sci 2012; 258: 7213-7218.10.1016/j.apsusc.2012.04.040 ↗