journal article·2011Open access

Effects of surface roughness and tapered angle of cone crown telescopic system on retentive force

Yoshiyuki SAKAI, Hidekazu TAKAHASHI, Naohiko IWASAKI, Yoshimasa IGARASHI

Dental Materials Journal· Volume 30· Issue 5

Abstract

This study evaluated the effect of surface roughness and tapered angle of cone crowns on retentive force (RF). Cone crowns from Ti-6Al-7Nb alloy with a tapered angle of 4, 5, or 6° were fabricated using a milling machine and a finishing machine to produce a smooth surface. Cone crowns of 6° with a rough surface were also prepared. The RF during 1,000 cycles of insertion/separation was recorded. The first RF of the 6° cone crowns was 24.2-27.7 N, and the surface roughness was not significant. The RF of all specimens decreased at 100 cycles, then those of inner and outer crowns with the same roughness remained unchanged, but those of different roughnesses increased with number of cycles. The RF of cone crowns with a smaller tapered angle was significantly greater than with a larger angle at any measured cycles.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Metal and Thin Film Mechanics · Orthopaedic implants and arthroplasty · Advanced machining processes and optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (42)

Show source-provided references
1. 1) Igarashi Y, Goto T. Ten-year follow-up study of conical crown retained dentures. Int J Prosthodont 1997; 10: 149-155.
2. 10.1046/j.1365-2842.1999.00345.x10.1046/j.1365-2842.1999.00345.x ↗
3. 10.1067/mpr.2000.10802610.1067/mpr.2000.108026 ↗
4. 10.2186/jjps.38.125210.2186/jjps.38.1252 ↗
5. 10.4012/dmj.2010-01110.4012/dmj.2010-011 ↗
6. 10.1016/S0022-3913(05)80264-110.1016/S0022-3913(05)80264-1 ↗
7. 10.1046/j.1365-2842.2000.00506.x10.1046/j.1365-2842.2000.00506.x ↗
8. 8) Anusavice KJ, Cascone P. In: Anusavice KJ, editor. Phillips’ Dental casting and soldering alloy. 11th ed. St. Louis: Saunders Co; 2003. p. 604-605.
9. 9) Mori T, Togaya T, Jean-Louis M, Yabugami M. Titanium for removable dentures. I. Laboratory procedures. J Oral Rehabil 1997; 24: 338-341.10.1046/j.1365-2842.1997.d01-301.x ↗
10. 10) Matsuno H, Yokoyama A, Watari F, Uo M, Kawasaki T. Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium. Biomaterials 2001; 22: 1253-1262.10.1016/S0142-9612(00)00275-1 ↗
11. 11) Khan MA, Williams RL, Williams DF. In-vitro corrosion and wear of titanium alloys in the biological environment. Biomaterials 1996; 17: 2117-2126.10.1016/0142-9612(96)00029-4 ↗
12. 12) Iijima D, Yoneyama T, Doi H, Hamanaka H, Kurosaki N. Wear properties of Ti and Ti-6Al-7Nb castings for dental prostheses. Biomaterials 2003; 24: 1519-1524.10.1016/S0142-9612(02)00533-1 ↗
13. 10.1023/A:100890940894810.1023/A:1008909408948 ↗
14. 10.1002/jbm.1041310.1002/jbm.10413 ↗
15. 10.1902/jop.2004.75.6.90910.1902/jop.2004.75.6.909 ↗
16. 10.1563/0-815.110.1563/0-815.1 ↗
17. 10.1016/S0022-3913(07)60062-610.1016/S0022-3913(07)60062-6 ↗
18. 18) Heckmann SM, Winter W, Meyer M, Weber HP, Wichmann MG. Overdenture attachment selection and the loading of implant and denture-bearing area. Part 1: In vivo verification of stereolithographic model. Clin Oral Implants Res 2008; 12: 612-623.
19. 10.1034/j.1600-0501.2001.120613.x10.1034/j.1600-0501.2001.120613.x ↗
20. 10.1111/j.1600-0501.2007.01500.x10.1111/j.1600-0501.2007.01500.x ↗
21. 21) Preiskel HW, Tsolka P. Telescopic prostheses for implants. Int J Oral Maxillofac Implants 1998; 13: 352-357.
22. 22) Zhang RG, Hannak WB, Roggensack M, Freesmeyer WB. Retentive characteristscs of ankylos syncone conical crown system over long-term use in vitro. Eur J Prosthodont Rest Dent 2008; 16: 61-66.
23. 23) Eccellente T, Piombino M, Piattelli A, Perrotti V, Iezzi G. A new treatment concept for immediate loading of implants inserted in the edentulous mandible. Quintessence Int 2010; 41: 489-495.
24. 24) Bayer S, Stark H, Mues S, Keilig L, Schrader A, Enkling N. Retention force measurement of telescopic crowns. Clin Oral Invest 2010; 14: 607-611.10.1007/s00784-009-0315-z ↗
25. 25) Körber KH. Konuskronen: Das rationelle teleskopsystem einführung in klinik und technik. 5th ed. Heidelberg: Dr. Alfred Hüthig Verlag GmbH; 1988. p. 64-91.
26. 26) Kido H, Morikawa M, Takeya K, Chigusa R, Toyoda S. Experimental study on retention of the conic telescope crown part I. Effect of the inner crown form. J Jpn Prosthodont Soc 1993; 137: 256-260.10.2186/jjps.37.256 ↗
27. 10.4012/dmj.27.21110.4012/dmj.27.211 ↗
28. 28) Korber, KH. Konuskronen ein physikalisch definiertes Teleskopsystem. Dtsch Zahnarztl Z 1968; 23: 619-630.
29. 10.1111/j.1365-2842.2004.01036.x10.1111/j.1365-2842.2004.01036.x ↗
30. 30) Saito M, Notani K, Miura Y, Kawasaki T. Complications and failures in removable partial dentures: a clinical evaluation. J Oral Rehabil 2002; 29: 627-633.10.1046/j.1365-2842.2002.00898.x ↗
31. 31) Ohkawa S. Experimental studies on retentive force of telescope crowns. J Hiroshima Univ Dent Soc 1986; 18: 166-180.
32. 32) Sekiguchi Y, Kuroiwa A. Studies on pure titanium conical telescopic crown effect of changes in taper and heigt of inner crown on retentive force of outer crown made by cast on technique. J Dent Mater 2003; 22: 271-282.
33. 33) Yamamoto T. The effect of the surface roughness on retentive force in complete crowns. Tsurumi Univ Dent J 1983; 9: 29-47.
34. 34) Rutkunas V, Mizutani H, Takahashi H. Evaluation of stable retentive properties of overdenture attachments. J Oral Rehabil 2005; 7: 115-120.
35. 35) Miura E, Takayama Y, Kawai Y, Hosoi T, Mizuno Y. Analysis of polished surfaces of titanium castings. J Prosthet Dent 2007; 51: 11-21.
36. 36) Riley WF, Sturges LD. Engineering mechanics: statics. 2nd ed. New York, Wiley & Sons: 1996. p. 471-534.
37. 37) Kawasaki T. The basic study of attachment alloys. The influence of retention force by abrasion of attachment. J Prosthet Dent 1981; 25: 770-785.10.2186/jjps.25.770 ↗
38. 38) Ogishi K. Experimental studies on retentive force of konuskronen. Tsurumi Univ Dent J 1984; 10: 169-182.
39. 10.1002/1097-4636(2000)53:4<320::AID-JBM6>3.0.CO;2-W10.1002/1097-4636(2000)53:4<320::AID-JBM6>3.0.CO;2-W ↗
40. 40) Nemoto T. Influence of the setting and removal times of konus telescope crowns fabricated using a CAD/CAM system on retentive force. Ohu Univ Dent J 2008; 35: 183-192.
41. 41) Tsuru H. Outline of the telescopic crown as a partial denture retainer. J Hiroshima Univ Dent Soc 1974; 6: 6-12.
42. 42) Ohkubo C, Shimura I, Aoki T, Hanatani S, Hosoi T, Hattori M, Oda Y, Okabe M. Wear resistance of experimental Ti-Cu alloys. Biomaterials 2003; 24: 3377-3381.10.1016/S0142-9612(03)00157-1 ↗