The effect of disinfectants on the accuracy, quality and surface structure of impression materials and gypsum casts: A comparative study using light microscopy, scanning electron microscopy and micro computed tomography
Source abstract
Abstract
The aim of this study was to compare the effect of several commercially available disinfectants on the accuracy of various types of impression materials and their compatibility with gypsum including surface quality and structure evaluation. Four alginate and three elastomeric impression materials in combination with disinfectants Aseptoprint Liquid, Zeta 7 solution, Silosept and Dentaclean Form were tested. The dimensional changes, detail reproduction, the compatibility with gypsum and surface/subsurface morphology were evaluated using light microscopy, scanning electron microscopy and micro computed tomography. Two alginate materials disinfected in Dentaclean Form exhibited the most significant differences (p<0.0001). The loss of detail on some alginate impressions in combination with this disinfectant including deterioration and change of morphology of gypsum surfaces was observed. Porosity in subsurface area and exposed large particles were detected. It was confirmed that the desired properties of impressions may be negatively affected in combination with some disinfectants.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Dental Erosion and Treatment
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Institute of Dental Medicine, General University Hospital in Prague and First Faculty of Medicine, Charles University
References (24)
Show source-provided references
1. 1) Al-Jabrah O, Al-Shumailan Y, Al-Rashdan M. Antimicrobial effect of 4 disinfectants on alginate, polyether, and polyvinyl siloxane impression materials. Int J Prosthodont 2007; 20: 299-307.
2. 2) Badrian H, Ghasemi E, Khalighinejad N, Hosseini N. The effect of three different disinfection materials on alginate impression by spray method. ISRN Dent 2012; 1-5.10.5402/2012/695151 ↗
3. 3) Correia-Sousa J, Tabaio AM, Silva A, Pereira T, Sampaio-Maia B, Vasconcelos M. The effect of water and sodium hypochlorite disinfection on alginate impressions. Rev Port Estomatol Med Dent Cir Maxilofac 2013; 54: 8-12.10.1016/j.rpemd.2012.12.003 ↗
4. 4) Almortadi N, Chadwick RG. Disinfection of dental impressions-compliance to accepted standards. Br Dent J 2010; 209: 607-611.10.1038/sj.bdj.2010.1134 ↗
5. 5) Lynch D, Allen PF. Quality of written prescriptions and master impressions for fixed and removable prosthodontics: a comparative study. Br Dent J 2005; 198: 17-20.10.1038/sj.bdj.4811947 ↗
6. 6) Johnson GH, Chellis KD, Gordon GE, Lepe X. Dimensional stability and detail reproduction of irreversible hydrocolloid and elastomeric impressions disinfected by immersion. J Prosthet Dent 1998; 79: 446-453.10.1016/S0022-3913(98)70160-X ↗
7. 7) Martin N, Martin MV, Jedynakiewicz NM. The dimensional stability of dental impression materials following immersion in disinfecting solutions. Dent Mater 2007; 23: 760-768.10.1016/j.dental.2007.01.004 ↗
8. 8) Suprono MS, Kattadiyil MT, Goodacre ChJ, Winer MS. Effect of disinfection on irreversible hydrocolloid and alternative impression materials and the resultant gypsum casts. J Prosthet Dent 2012; 108: 250-258.10.1016/S0022-3913(12)60173-5 ↗
9. 9) Lepe X, Johnson GH, Berg JC, Aw TC, Stroh GS. Wettability, imbibition, and mass change of disinfected low-viscosity impression materials. J Prosthet Dent 2002; 88: 268-276.10.1067/mpr.2002.128757 ↗
10. 10) Shetty S, Kamat G, Shetty R. Wettability changes in polyether impression materials subjected to immersion disinfection. Dent Res J (Isfahan) 2013; 10: 539-544.
11. 11) Chidambaranathan AS, Balasubramanium M. Comprehensive review and comparison of the disinfection techniques currently available in the literature. J Prosthodont 2019; 28: e849-e856.10.1111/jopr.12597 ↗
12. 12) ISO 21563 Dentistry Hydrocolloid impression materials. Geneva: International organization for standardization; 2013.
13. 13) ISO 4823 Dentistry Elastomeric impression materials. Geneva: International organization for standardization; 2015.
14. 14) Taylor RL, Wright PS, Maryan Ch. Disinfection procedures: their effect on the dimensional accuracy and surface quality of irreversible hydrocolloid impression materials and gypsum casts. Dent Mater 2002; 18: 103-110.10.1016/S0109-5641(01)00027-6 ↗
15. 15) Fellows CM, Thomas GA. Determination of bound and unbound water in dental alginate irreversible hydrocolloid by nuclear magnetic resonance spectroscopy. Dent Mater 2009; 25: 486-493.10.1016/j.dental.2008.10.001 ↗
16. 16) Garg S, Mittal S, Bansal S, Kansal G. A study on imbibition and syneresis in four commercially available irreversible hydrocolloid (alginate) impression materials. Int J Prosthodont Restor Dent 2012; 2: 1-4.
17. 17) Muzaffar D, Braden M, Parker S, Patel MP. The effect of disinfecting solutions on the dimensional stability of dental alginate impression materials. Dent Mater 2012; 28: 749-755.10.1016/j.dental.2012.03.013 ↗
18. 18) Nallamuthu NA, Braden M, Patel MP. Some aspects of the formulation of alginate dental impression materials - Setting characteristics and mechanical properties. Dent Mater 2012; 28: 756-762.10.1016/j.dental.2012.03.012 ↗
19. 19) Rad FH, Ghaffari T, Safavi SH. In vitro evaluation of dimensional stability of alginate impressions after disinfection by spray and immersion methods. J Dent Res Dent Clin Dent Prospects 2010; 4: 130-135.
20. 20) Guiraldo RD, Borsato TT, Berger SB, Lopes MB, Gonini-Jr A, Sinhoreti MAC. Surface detail reproduction and dimensional accuracy of stone models: Influence of disinfectant solutions and alginate impression materials. Braz Dent J 2012; 23: 417-421.10.1590/S0103-64402012000400018 ↗
21. 21) Amalan A, Ginjupalli K, Upadhya N. Evaluation of properties of irreversible hydrocolloid impression materials mixed with disinfectant liquids. Dent Res J 2013; 10: 65-73.
22. 22) Wang J, Wan Q, Chao Y, Chen Y. A self-disinfecting irreversible hydrocolloid impression material mixed with chlorhexidine solution. Angle Orthod 2007; 77: 894-900.10.2319/070606-277 ↗
23. 24) Carvalhal CIO, Nunes de Melo JA, Sobrinho LC, Correr AB, Sinhoreti MAC. Dimensional change of elastomeric materials after immersion in disinfectant solutions for different times. J Contemp Dent Pract 2011; 12: 252-258.10.5005/jp-journals-10024-1043 ↗
24. 25) Poulis N, Prombonas A, Yannikakis S. Preliminary SEM observations on the surface of elastomeric impression materials after immersion or ozone disinfection. J Clin Diagn Res 2016; 10: 1-5.10.7860/JCDR/2016/20330.8949 ↗