Impact of polymerization and storage on the degree of conversion and mechanical properties of veneering resin composites
Source abstract
Abstract
To investigate the degree of conversion (DC), Martens hardness (HM), elastic indentation modulus (EIT), and flexural strength (FS) of veneering resin composites (SR Nexco Paste (NP), Ceramage Incisal (CI), Gradia Plus (GP); n=60/group) cured with different polymerization devices (bre.Lux Power Unit, Labolight DUO, Otoflash G171, LC-3DPrint Box, PCU LED; n=12/subgroup) after storage. Otoflash G171 and Labolight DUO showed increased DC/HM/EIT. CI presented the lowest DC and highest HM/EIT. NP showed the highest DC and lowest HM/EIT. Within Otoflash G171, Laboligth DUO and PCU LED, highest FS was observed for CI. Storage did not affect DC/HM/EIT for specimens cured with Otoflash G171 or Labolight DUO. With storage not showing an influence on the tested parameters for polymerization devices that otherwise presented superior results, increased storage time cannot be recommended. For the tested resin composites, this study observed a high/low degree of conversion to coincide with respectively low/high amounts of fillers/mechanical properties.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Building materials and conservation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Prosthetic Dentistry, University Hospital, LMU Munich
Department of Conservative Dentistry and Periodontology, University Hospital, LMU Munich
Spectroscopy Products Division, Renishaw GmbH
Private Office
References (40)
Show source-provided references
1. 1) Ilie N, Hickel R. Resin composite restorative materials. Aust Dent J 2011; 56 Suppl 1: 59-66.10.1111/j.1834-7819.2010.01296.x ↗
2. 2) Yadav RD, Raisingani D, Jindal D, Mathur R. A comparative analysis of different finishing and polishing devices on nanofilled, microfilled, and hybrid composite: A scanning electron microscopy and profilometric study. Int J Clin Pediatr Dent 2016; 9: 201-208.10.5005/jp-journals-10005-1364 ↗
3. 3) Beun S, Glorieux T, Devaux J, Vreven J, Leloup G. Characterization of nanofilled compared to universal and microfilled composites. Dent Mater 2007; 23: 51-59.10.1016/j.dental.2005.12.003 ↗
4. 4) Alzraikat H, Burrow MF, Maghaireh GA, Taha NA. Nanofilled resin composite properties and clinical performance: A review. Oper Dent 2018; 43: E173-E190.10.2341/17-208-T ↗
5. 5) Borba M, Della Bona A, Cecchetti D. Flexural strength and hardness of direct and indirect composites. Braz Oral Res 2009; 23: 5-10.10.1590/S1806-83242009000100002 ↗
6. 6) Alves PB, Brandt WC, Neves AC, Cunha LG, Silva-Concilio LR. Mechanical properties of direct and indirect composites after storage for 24 h and 10 months. Eur J Dent 2013; 7: 117-122.
7. 7) Ferracane JL. Elution of leachable components from composites. J Oral Rehabil 1994; 21: 441-452.10.1111/j.1365-2842.1994.tb01158.x ↗
8. 8) dos Santos RL, de Sampaio GA, de Carvalho FG, Pithon MM, Guenes GM, Alves PM. Influence of degree of conversion on the biocompatibility of different composites in vivo. J Adhes Dent 2014; 16: 15-20.
9. 9) Ikemura K, Endo T. A review of the development of radical photopolymerization initiators used for designing light-curing dental adhesives and resin composites. Dent Mater J 2010; 29: 481-501.10.4012/dmj.2009-137 ↗
10. 10) Santini A, Gallegos IT, Felix CM. Photoinitiators in dentistry: a review. Prim Dent J 2013; 2: 30-33.10.1308/205016814809859563 ↗
11. 11) Mousavinasab SM. Biocompatibility of composite resins. Dent Res J (Isfahan) 2011; 8: S21-29.
12. 12) Bettencourt AF, Neves CB, de Almeida MS, Pinheiro LM, Oliveira SA, Lopes LP, et al. Biodegradation of acrylic based resins: A review. Dent Mater 2010; 26: e171-180.10.1016/j.dental.2010.01.006 ↗
13. 13) Tsuda H, Arends J. Raman spectroscopy in dental research: a short review of recent studies. Adv Dent Res 1997; 11: 539-547.10.1177/08959374970110042301 ↗
14. 14) Pianelli C, Devaux J, Bebelman S, Leloup G. The micro-Raman spectroscopy, a useful tool to determine the degree of conversion of light-activated composite resins. J Biomed Mater Res 1999; 48: 675-681.10.1002/(SICI)1097-4636(1999)48:5<675::AID-JBM11>3.0.CO;2-P ↗
15. 15) Mohamad D, Young RJ, Mann AB, Watts DC. Post-polymerization of dental resin composite evaluated with nanoindentation and micro-Raman spectroscopy. Arch Orofac Sci 2007; 2: 26-31.
16. 16) Galvao MR, Caldas SG, Bagnato VS, de Souza Rastelli AN, de Andrade MF. Evaluation of degree of conversion and hardness of dental composites photo-activated with different light guide tips. Eur J Dent 2013; 7: 86-93.
17. 17) DIN ISO 14577. Metallic materials - Instrumented indentation test for hardness and materials parameters —Part 1: Test method (ISO 14577-1:2015) 2015.
18. 18) Greaves GN, Greer AL, Lakes RS, Rouxel T. Poisson’s ratio and modern materials. Nat Mater 2011; 10: 823-837.10.1038/nmat3134 ↗
19. 19) DIN ISO 6872. Dentistry —Ceramic materials 2008.
20. 20) Butikofer L, Stawarczyk B, Roos M. Two regression methods for estimation of a two-parameter Weibull distribution for reliability of dental materials. Dent Mater 2015; 31: e33-50.10.1016/j.dental.2014.11.014 ↗
21. 21) Calheiros FC, Daronch M, Rueggeberg FA, Braga RR. Degree of conversion and mechanical properties of a BisGMA:TEGDMA composite as a function of the applied radiant exposure. J Biomed Mater Res B Appl Biomater 2008; 84: 503-509.10.1002/jbm.b.30897 ↗
22. 22) Peutzfeldt A. Resin composites in dentistry: the monomer systems. Eur J Oral Sci 1997; 105: 97-116.10.1111/j.1600-0722.1997.tb00188.x ↗
23. 23) Chung KH, Greener EH. Correlation between degree of conversion, filler concentration and mechanical properties of posterior composite resins. J Oral Rehabil 1990; 17: 487-494.10.1111/j.1365-2842.1990.tb01419.x ↗
24. 24) Halvorson RH, Erickson RL, Davidson CL. The effect of filler and silane content on conversion of resin-based composite. Dent Mater 2003; 19: 327-333.10.1016/S0109-5641(02)00062-3 ↗
25. 25) Imazato S, McCabe JF, Tarumi H, Ehara A, Ebisu S. Degree of conversion of composites measured by DTA and FTIR. Dent Mater 2001; 17: 178-183.10.1016/S0109-5641(00)00066-X ↗
26. 26) Peutzfeldt A, Sahafi A, Asmussen E. Characterization of resin composites polymerized with plasma arc curing units. Dent Mater 2000; 16: 330-336.10.1016/S0109-5641(00)00025-7 ↗
27. 27) Reymus M, Fabritius R, Kessler A, Hickel R, Edelhoff D, Stawarczyk B. Fracture load of 3D-printed fixed dental prostheses compared with milled and conventionally fabricated ones: the impact of resin material, build direction, post-curing, and artificial aging-an in vitro study. Clin Oral Investig 2020; 24: 701-710.10.1007/s00784-019-02952-7 ↗
28. 28) Cramer NB, Stansbury JW, Bowman CN. Recent advances and developments in composite dental restorative materials. J Dent Res 2011; 90: 402-416.10.1177/0022034510381263 ↗
29. 29) Rueggeberg FA. State-of-the-art: dental photocuring: a review. Dent Mater 2011; 27: 39-52.10.1016/j.dental.2010.10.021 ↗
30. 30) Franz A, Konig F, Lucas T, Watts DC, Schedle A. Cytotoxic effects of dental bonding substances as a function of degree of conversion. Dent Mater 2009; 25: 232-239.10.1016/j.dental.2008.07.003 ↗
31. 31) Ghavami-Lahiji M, Firouzmanesh M, Bagheri H, Jafarzadeh Kashi TS, Razazpour F, Behroozibakhsh M. The effect of thermocycling on the degree of conversion and mechanical properties of a microhybrid dental resin composite. Restor Dent Endod 2018; 43: e26.10.5395/rde.2018.43.e26 ↗
32. 32) Tonetto MR, Pinto SC, Rastelli Ade N, Borges AH, Saad JR, Pedro FL, et al. Degree of conversion of polymer-matrix composite assessed by FTIR analysis. J Contemp Dent Pract 2013; 14: 76-79.10.5005/jp-journals-10024-1274 ↗
33. 33) Zissis A, Yannikakis S, Polyzois G, Harrison A. A long term study on residual monomer release from denture materials. Eur J Prosthodont Restor Dent 2008; 16: 81-84.
34. 34) Bayraktar G, Guvener B, Bural C, Uresin Y. Influence of polymerization method, curing process, and length of time of storage in water on the residual methyl methacrylate content in dental acrylic resins. J Biomed Mater Res B Appl Biomater 2006; 76: 340-345.10.1002/jbm.b.30377 ↗
35. 35) Franz A, Konig F, Anglmayer M, Rausch-Fan X, Gille G, Rausch WD, et al. Cytotoxic effects of packable and nonpackable dental composites. Dent Mater 2003; 19: 382-392.10.1016/S0109-5641(02)00081-7 ↗
36. 36) Durner J, Obermaier J, Draenert M, Ilie N. Correlation of the degree of conversion with the amount of elutable substances in nano-hybrid dental composites. Dent Mater 2012; 28: 1146-1153.10.1016/j.dental.2012.08.006 ↗
37. 37) Obradvoic-Djuricic Koskova MV, Radisic Marina, Lausevic Mila. Correlation between the degree of conversion and the elution of leachable components from dental resin-based cements. J Serb Chem Soc 2011; 76: 1307-1323.10.2298/JSC100610113O ↗
38. 38) Fischer J, Roeske S, Stawarczyk B, Hammerle CH. Investigations in the correlation between Martens hardness and flexural strength of composite resin restorative materials. Dent Mater J 2010; 29: 188-192.10.4012/dmj.2009-080 ↗
39. 39) Everall NJ. Confocal Raman microscopy: common errors and artefacts. Analyst 2010; 135: 2512-2522.10.1039/c0an00371a ↗
40. 40) Adar F. Developments in Raman Microanalysis, San Francisco, San Francisco Press, 1981, p. 67.