Study of corrosion of combinations of titanium/Ti-6Al-4V implants and dental alloys
Source abstract
Abstract
Metal ions released in 1% lactic acid solution from combinations of titanium fixtures with superstructures made of dental precious metal alloys (dental alloys) and titanium and differences based on the fixing method were investigated. In combinations of titanium with dental alloys, the level of Ti release was influenced by micro-structure of titanium: it was lower when the grain size was smaller. In titanium-titanium combinations, differences in the micro-structure of metal also markedly influenced the dissolution: the level of release increased when the micro-structure of titanium was different. The Ti and V release levels were higher in combination with titanium alloy and titanium than with titanium alloy and dental alloys. Regarding the superstructure-fixture fixing method, the level of Ti release was significantly lower in cement than in direct fixation.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Dental materials and restorations · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Division of Biomaterials, Department of Hard Tissue Research, Graduate School of Oral Medicine, Matsumoto Dental University
References (40)
Show source-provided references
1. 1) Chee W, Felton DA, Johnson PF, Sullivan DY. Cemented versus screw-retained implant prostheses: which is better? Int J Oral Maxillofac Implants 1999; 14: 137-141.
2. 2) Guichet DL, Caputo AA, Choi H, Sorensen JA. Passivity of fit and marginal opening in screw-or cement-retained implant fixed partial denture designs. Int J Oral Maxillofac Implants 2000; 15: 239-246.
3. 3) Karl M, Rosch M, Graef F, Taylor TD, Heckmann SM. Static implant loading caused by as-cast metal and ceramic-veneered superstructures. J Prosthet Dent 2005; 93: 324-330.10.1016/j.prosdent.2004.12.006 ↗
4. 4) Zarone F, Sorrentino R, Traini T, Lorio DD, Caputi S. Fracture resistance of implant-supported screw-versus cement-retained porcelain fused to metal single crowns: SEM fractographic analysis. Dent Mater 2007; 23: 296-301.10.1016/j.dental.2005.10.013 ↗
5. 5) Karl M, Graef F, Taylor TD, Heckmann SM. In vitro effects of load cycling on metal-ceramic cement- and screw-retained implant restorations. J Prosthet Dent 2007; 97: 137-140.10.1016/j.prosdent.2007.01.001 ↗
6. 6) Tamura K, Yoshida T, Yamazoe M, Mizoguch T, Niiro T, Kawase Y, Nagasawa S, Ito M. Hardness and metallographic structure of commercial titanium wires and implants. Proceedings of the 87th General Session & Exhibition of the IADR; 2009 Apr 1-4; Miami, FLA, USA. Alexandria, VA: IADR; 2009. p. 114942.
7. 7) Johansson BI, Lemons JE, Hao SQ. Corrosion of dental copper, nickel, and gold alloys in artificial saliva and saline solutions. Dent Mater 1989; 5: 324-328.10.1016/0109-5641(89)90124-3 ↗
8. 8) Japanese Industrial Standards Committee, Testing method for corrosion resistance of metallic biomaterials by anodic polarization measurement, JIS T 0302:2000, Tokyo: Japanese Standard Association; 2000. p. 1-18.
9. 9) Koike M, Fujii H. The corrosion resistance of pure titanium in organic acids. Biomaterials 2001; 22: 2931-2936.10.1016/S0142-9612(01)00040-0 ↗
10. 10) Huang HH, Chiu YH, Lee TH, Wu SC, Yang HW, Su KH, Hsu CC. Ion release from NiTi orthodontic wires in artificial saliva with various acidities. Biomaterials 2003; 24: 3585-3592.10.1016/S0142-9612(03)00188-1 ↗
11. 11) Yoneyama T, Doi H, Hamanaka H. Released metallic ion from Ti, Ti-6Al-4V alloy and Ni-Ti alloy. Seitai Zairyo 1993; 11: 71-78.
12. 12) Okazaki Y, Gotoh E, Manabe T, Kobayashi K. Comparison of metal concentrations in rat tibia tissues with various metallic implants. Biomaterials 2004; 25: 5913-5920.10.1016/j.biomaterials.2004.01.064 ↗
13. 13) Reclaru L, Meyer JM. Study of corrosion between a titanium implant and dental alloys. J Dent 1994; 22: 159-168.10.1016/0300-5712(94)90200-3 ↗
14. 14) Tanaka K. Corrosion mechanism of coupled dental alloys. Tohoku Univ Dent J 1996; 14: 119-138.
15. 15) Nakada H, Okazaki Y, Saeki H, Kobayashi K, Tateishi T. Galvanic corrosion of various dental alloys and centrifugally cast new titanium alloy couples. Seitai Zairyo 1998; 16: 243-253.
16. 16) Venugopalan R, Lucas LC. Evaluation of restorative and implant alloys galvanically coupled to titanium. Dent Mater 1998; 14: 165-172.10.1016/S0109-5641(98)00024-4 ↗
17. 17) Cortada M, Giner LL, Costa S, Gil FJ, Rodriguez D, Planell JA. Galvanic corrosion behavior of titanium implants coupled to dental alloys. J Mater Sci Mater Med 2000; 11: 287-293.10.1023/A:1008905229522 ↗
18. 18) Kitamura T, Yoshinari M, Oda Y. Electrochemical behavior of coupled dental implant alloys. Shikwa Gakuho 2002; 102: 665-675.
19. 19) Sakaihara I, Yamazoe M, Anraku T, Yoshida T, Tamura K, Nagasawa S, Ito M. Corrosion resistance of dental precious metal alloys in pseudo-oral environment. Matsumoto Shigaku 2007; 33: 200-209.
20. 20) Gettleman L, Cocks FH, Darmiento LA, Levine PA, Wright S, Nathanson D. Measurement of in vivo corrosion rates in baboons, and correlation with in vitro tests. J Dent Res 1980; 59: 689-707.10.1177/00220345800590040601 ↗
21. 21) Marek M. Corrosion in a biological environment. Proceedings of the International workshop on Biocompatibility, toxicity and hypersensitivity to alloy system used in dentistry; 1985 Jun 23-28; Ann Arbor, MI, USA. Michigan: University of Michigan School of Dentistry; 1986. p. 103-122.
22. 22) Lucas LC, Lemons JE. Biodegradation of restorative metallic systems. Adv Dent Res 1992; 6: 32-37.10.1177/08959374920060011301 ↗
23. 23) Laub LW, Stanford JW. Tarnish and corrosion behavior of dental gold alloys. Gold Bull 1981; 14: 13-1810.1007/BF03216554 ↗
24. 24) The Japan Institute of Metals. Kinzoku data book. 4th ed. Tokyo: Maruzen Co; 2004. p. 519.
25. 25) Suzuki K, Umemoto K, Okazaki M, Nakajima H, Nishiyama, N. Standard dental materials science. 4th ed. Tokyo: Gakkensyoin; 2009. p. 17.
26. 26) Kusamichi H. Application of titanium metal. 1st ed. Tokyo: The Nikkan Kogyo Shinbun; 1987. p. 218-223.
27. 27) Foti B, Tavitian P, Tosello A, Bonfil JJ, Franquin JC. Polymetallism and osseointegration in oral implantology: pilot study on primate. J Oral Rehabil 1999; 26: 495-502.10.1046/j.1365-2842.1999.00404.x ↗
28. 28) Grosgogeat B, Reclaru L, Lissac M, Dalard F. Measurement and evaluation of galvanic corrosion between titanium/ Ti6Al4V implants and dental alloys by electrochemical techniques and auger spectrometry. Biomaterials 1999; 20: 933-941.10.1016/S0142-9612(98)00248-8 ↗
29. 29) Inoue M. Epidemiological survey of metal allergy and its relationship with oral metal restorations. Grant-in-Aid for Co-operative Research (A). Research Project Number : 01304047 Final Research Report, 1992.
30. 30) Dietary reference intakes for Japanese (2010), Japan: Ministry of health, Labor and welfare; 2009. p. 218-275.
31. 31) Yamamoto A, Honda R, Sumita M. Cytotoxicity evaluation of 43 metal salts using murine fibroblasts and osteoblasttic cells. J Biomed Mater Res 1998; 39: 331-340.10.1002/(SICI)1097-4636(199802)39:2<331::AID-JBM22>3.0.CO;2-E ↗
32. 32) Fujimoto K. An Experimental Study of Ti-Ni binary alloy as the material for implant. J Jpn Soc Oral Implant 1986; 7: 25-55.
33. 33) Roppongi S, Higo Y. Experimental study on corrosion behavior in total Joint prosthesis employing different metals. Seitai Zairyo 1995; 13: 5-13.
34. 34) Meachim G, Williams DF. Changes in nonosseous tissue adjacent to titanium implants. J Biomed Mater Res 1973; 7: 555-572.10.1002/jbm.820070607 ↗
35. 35) Schweitzer A. First report of a titanium allergy. Dermatosen 1997; 45: 190.
36. 36) Nakano T, Ko N, Ko R, Shimazu T, Egusa H, Yamada S, Yatani H. Titanium allergy of dental implant. : A Case Report. Proceedings of the 37th Academic Conference of the Japanese Society of Oral Implantology; 2007 Sep 14-16; Kumamoto, Japan. Tokyo: Japanese Society of Oral Implantology; 2007. p. 339.
37. 37) Tamai K, Mitsumori M, Fujishiro S, Kokubo M, Ooya N, Nagata Y, Sasai K, Hiraoka M, Inamoto T. A Case of allergic reaction to surgical metal clips inserted for postoperative boost irradiation in a patient undergoing breast-conserving therapy. Breast Cancer 2001; 8: 90-92.10.1007/BF02967485 ↗
38. 38) Takada A, Ujigawa K, Okazaki Y, Ozawa Y, Morimoto M, Tonogi M, Yamane G. A case suspected hypersensitivity to titanium lymphocyte transformation test for hypersensitivity to titanium. Proceedings of the 37th Academic Conference of the Japanese Society of Oral Implantology; 2007 Sep 14-16; Kumamoto, Japan. Tokyo: Japanese Society of Oral Implantology; 2007. p. 339.
39. 39) Okazaki Y, Kyo K, Ito Y, Tateishi T. Effect of friction on the corrosion resistance for implant alloys in physiological saline solution. J Japan Inst Metals 1997; 61: 1122-1131.10.2320/jinstmet1952.61.10_1122 ↗
40. 40) Kumazawa R, Watari F, Takashi N, Tanimura Y, Uo M, Totsuka Y. Effects of Ti ions and particles on neutrophil function and morphology. Biomaterials 2002; 23: 3757-3764.10.1016/S0142-9612(02)00115-1 ↗