journal article·2020-03-27Open access

Enhanced root canal-centering ability and reduced screw-in force generation of reciprocating nickel-titanium instruments with a post-machining thermal treatment

Keiichiro MAKI, Arata EBIHARA, Shunsuke KIMURA, Miki NISHIJO, Daisuke TOKITA, Kana MIYARA, Takashi OKIJI

Dental Materials Journal· Volume 39· Issue 2

Abstract

This study aimed to evaluate the influence of a post-machining thermal treatment on canal-centering ability and torque/force generation of reciprocating nickel-titanium instruments. Simulated J-shaped resin canals were prepared with reciprocating instruments sharing identical geometric architecture and with/without post-machining thermal treatment (Reciproc Blue/Reciproc, VDW, Munich, Germany). Using an original automated root canal instrumentation and torque/force analyzing device, files were operated in a combination of reciprocation and up-and-down motion, and torque/force values were monitored. Canal-centering ratios were measured after superimposition of pre- and post-instrumentation images. Compared with Reciproc, Reciproc Blue showed a significantly lower canal-centering ratio (i.e., less deviation; p<0.05) at 0-1 mm from the apex and generated a significantly smaller upward maximum vertical force (p<0.05). Under standardized conditions using the automated device, Reciproc Blue showed better canal-centering ability and reduced screw-in forces than Reciproc, indicating that the post-machining thermal treatment confers superior performance to reciprocating nickel-titanium instruments.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Endodontics and Root Canal Treatments · Dental materials and restorations · Dental Radiography and Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)

References (35)

Show source-provided references
1. 1) Ebihara A, Yahata Y, Miyara K, Nakano K, Hayashi Y, Suda H.Heat treatment of nickel-titanium rotary endodontic instruments: effects on bending properties and shaping abilities. Int Endod J 2011; 44: 843-849.10.1111/j.1365-2591.2011.01891.x ↗
2. 2) Gambill JM, Alder M, del Rio CE. Comparison of nickel-titanium and stainless steel hand-file instrumentation using computed tomography. J Endod 1996; 22: 369-375.10.1016/S0099-2399(96)80221-4 ↗
3. 3) Hamid HR, Gluskin AH, Peters OA, Peters CI. Rotary versus reciprocation root canal preparation: Initial clinical quality assessment in a novice clinician cohort. J Endod 2018; 44: 1257-1262.10.1016/j.joen.2018.04.017 ↗
4. 4) Vadhana S, SaravanaKarthikeyan B, Nandini S, Velmurugan N. Cyclic fatigue resistance of RaCe and Mtwo rotary files in continuous rotation and reciprocating motion. J Endod 2014; 40: 995-999.10.1016/j.joen.2013.12.010 ↗
5. 5) Lopes HP, Gambarra-Soares T, Elias CN, Siqueira JF Jr, Inojosa IF, Lopes WS, et al. Comparison of the mechanical properties of rotary instruments made of conventional nickel-titanium wire, M-wire, or nickel-titanium alloy in R-phase. J Endod 2013; 39: 516-520.10.1016/j.joen.2012.12.006 ↗
6. 6) Perez-Higueras JJ, Arias A, de la Macorra JC. Cyclic fatigue resistance of K3, K3XF, and twisted file nickel-titanium files under continuous rotation or reciprocating motion. J Endod 2013; 39: 1585-1588.10.1016/j.joen.2013.07.020 ↗
7. 7) Shen Y, Qian W, Abtin H, Gao Y, Haapasalo M. Effect of environment on fatigue failure of controlled memory wire nickel-titanium rotary instruments. J Endod 2012; 38: 376-380.10.1016/j.joen.2011.12.002 ↗
8. 8) Zupanc J, Vahdat-Pajouh N, Schäfer E. New thermomechanically treated NiTi alloys - a review. Int Endod J 2018; 51: 1088-1103.10.1111/iej.12924 ↗
9. 9) Zinelis S, Darabara M, Takase T, Ogane K, Papadimitriou GD. The effect of thermal treatment on the resistance of nickel-titanium rotary files in cyclic fatigue. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007; 103: 843-847.10.1016/j.tripleo.2006.12.026 ↗
10. 10) Caviedes-Bucheli J, Castellanos F, Vasquez N, Ulate E, Munoz HR. The influence of two reciprocating single-file and two rotary-file systems on the apical extrusion of debris and its biological relationship with symptomatic apical periodontitis. A systematic review and meta-analysis. Int Endod J 2016; 49: 255-270.10.1111/iej.12452 ↗
11. 11) Pedulla E, Grande NM, Plotino G, Gambarini G, Rapisarda E. Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel-titanium rotary instruments. J Endod 2013; 39: 258-261.10.1016/j.joen.2012.10.025 ↗
12. 12) Ahn SY, Kim HC, Kim E. Kinematic effects of nickel-titanium instruments with reciprocating or continuous rotation motion: A systematic review of in vitro studies. J Endod 2016; 42: 1009-1017.10.1016/j.joen.2016.04.002 ↗
13. 13) Pereira ES, Peixoto IF, Viana AC, Oliveira II, Gonzalez BM, Buono VT, et al. Physical and mechanical properties of a thermomechanically treated NiTi wire used in the manufacture of rotary endodontic instruments. Int Endod J 2012; 45: 469-474.10.1111/j.1365-2591.2011.01998.x ↗
14. 14) Pereira ES, Gomes RO, Leroy AM, Singh R, Peters OA, Bahia MG, et al. Mechanical behavior of M-Wire and conventional NiTi wire used to manufacture rotary endodontic instruments. Dent Mater 2013; 29: e318-e324.10.1016/j.dental.2013.10.004 ↗
15. 15) Shen Y, Zhou H, Coil JM, Aljazaeri B, Buttar R, Wang Z, et al. ProFile Vortex and Vortex Blue nickel-titanium rotary instruments after clinical use. J Endod 2015; 41: 937-942.10.1016/j.joen.2015.02.003 ↗
16. 16) De-Deus G, Silva EJ, Vieira VT, Belladonna FG, Elias CN, Plotino G, et al. Blue thermomechanical treatment optimizes fatigue resistance and flexibility of the Reciproc files. J Endod 2017; 43: 462-466.10.1016/j.joen.2016.10.039 ↗
17. 18) Keskin C, Inan U, Demiral M, Keles A. Cyclic fatigue resistance of Reciproc Blue, Reciproc, and WaveOne Gold reciprocating instruments. J Endod 2017; 43: 1360-1363.10.1016/j.joen.2017.03.036 ↗
18. 19) Tokita D, Ebihara A, Nishijo M, Miyara K, Okiji T. Dynamic torque and vertical force analysis during nickel-titanium rotary root canal preparation with different modes of reciprocal rotation. J Endod 2017; 43: 1706-1710.10.1016/j.joen.2017.05.010 ↗
19. 20) Nishijo M, Ebihara A, Tokita D, Doi H, Hanawa T, Okiji T. Evaluation of selected mechanical properties of NiTi rotary glide path files manufactured from controlled memory wires. Dent Mater J 2018; 37: 549-554.10.4012/dmj.2017-276 ↗
20. 21) Fukumori Y, Nishijyo M, Tokita D, Miyara K, Ebihara A, Okiji T. Comparative analysis of mechanical properties of differently tapered nickeltitanium endodontic rotary instruments. Dent Mater J 2018; 37: 667-674.10.4012/dmj.2017-312 ↗
21. 22) Maki K, Ebihara A, Kimura S, Nishijo M, Tokita D, Okiji T. Effect of different speeds of up-and-down motion on canal centering ability and vertical force and torque generation of nickel-titanium rotary instruments. J Endod 2019; 45: 68-72.10.1016/j.joen.2018.10.002 ↗
22. 23) Tsujimoto M, Irifune Y, Tsujimoto Y, Yamada S, Watanabe I, Hayashi Y. Comparison of conventional and new-generation nickel-titanium files in regard to their physical properties. J Endod 2014; 40: 1824-1829.10.1016/j.joen.2014.06.009 ↗
23. 25) Alcalde MP, Duarte MAH, Bramante CM, de Vasconselos BC, Tanomaru-Filho M, Guerreiro-Tanomaru JM, et al. Cyclic fatigue and torsional strength of three different thermally treated reciprocating nickel-titanium instruments. Clin Oral Investig 2018; 22: 1865-1871.10.1007/s00784-017-2295-8 ↗
24. 27) Ba-Hattab R, Prohl AK, Lang H, Pahncke D. Comparison of the shaping ability of GT® Series X, Twisted Files and AlphaKite rotary nickel-titanium systems in simulated canals. BMC Oral Health 2013; 13: 72.10.1186/1472-6831-13-72 ↗
25. 28) Zhang L, Luo HX, Zhou XD, Tan H, Huang DM. The shaping effect of the combination of two rotary nickel-titanium instruments in simulated s-shaped canals. J Endod 2008; 34: 456-458.10.1016/j.joen.2008.01.007 ↗
26. 29) Calberson FL, Deroose CA, Hommez GM, De Moor RJ. Shaping ability of ProTaper nickel-titanium files in simulated resin root canals. Int Endod J 2004; 37: 613-623.10.1111/j.1365-2591.2004.00860.x ↗
27. 30) European Society of Endodontology. Quality guidelines for endodontic treatment: consensus report of the European Society of Endodontology. Int Endod J 2006; 39: 921-930.10.1111/j.1365-2591.2006.01180.x ↗
28. 31) Peters OA. Current challenges and concepts in the preparation of root canal systems: a review. J Endod 2004; 30: 559-567.10.1097/01.DON.0000129039.59003.9D ↗
29. 32) Kim HC, Cheung GS, Lee CJ, Kim BM, Park JK, Kang SI. Comparison of forces generated during root canal shaping and residual stresses of three nickel-titanium rotary files by using a three-dimensional finite-element analysis. J Endod 2008; 34: 743-747.10.1016/j.joen.2008.03.015 ↗
30. 33) Hieawy A, Haapasalo M, Zhou H, Wang ZJ, Shen Y. Phase transformation behavior and resistance to bending and cyclic fatigue of ProTaper Gold and ProTaper Universal instruments. J Endod 2015; 41: 1134-1138.10.1016/j.joen.2015.02.030 ↗
31. 34) Pinheiro SR, Alcalde MP, Vivacqua-Gomes N, Bramante CM, Vivan RR, Duarte MAH, et al. Evaluation of apical transportation and centring ability of five thermally treated NiTi rotary systems. Int Endod J 2018; 51: 705-713.10.1111/iej.12881 ↗
32. 35) Belladonna FG, Carvalho MS, Cavalcante DM, Fernandes JT, de Carvalho Maciel AC, Oliveira HE, et al. Micro-computed tomography shaping ability assessment of the new blue thermal treated Reciproc instrument. J Endod 2018; 44: 1146-1150.10.1016/j.joen.2018.03.008 ↗
33. 36) Ha JH, Kwak SW, Kim SK, Kim HC. Screw-in forces during instrumentation by various file systems. Restor Dent Endod 2016; 41: 304-309.10.5395/rde.2016.41.4.304 ↗
34. 37) Ha JH, Cheung GS, Versluis A, Lee CJ, Kwak SW, Kim HC. ‘Screw-in’ tendency of rotary nickel-titanium files due to design geometry. Int Endod J 2015; 48: 666-672.10.1111/iej.12363 ↗
35. 38) Kwak SW, Ha JH, Lee CJ, El Abed R, Abu-Tahun IH, Kim HC. Effects of pitch length and heat treatment on the mechanical properties of the glide path preparation instruments. J Endod 2016; 42: 788-792.10.1016/j.joen.2016.02.002 ↗