Surface characteristics and castability of Zr-14Nb alloy dental castings
Source abstract
Abstract
The purpose of this study was to evaluate mechanical properties, surface characteristics and castability of Zr-14Nb dental castings. The mean 0.2% proof and ultimate tensile strengths of Zr-14Nb were approximately 68% and 76% those of Ti-6Al-7Nb, respectively, while they were comparable to Co-29Cr-6Mo. Elongation of Zr-14Nb was the highest of all alloys tested. The hardened reaction layer was formed on the surfaces of the Zr-14Nb castings. The layer consisted of oxygen and aluminum originating form investment. The castability of Zr-14Nb was comparable to that of Ti-6Al-7Nb. Dental castings of Zr-14Nb reveal mechanical properties that were within the range of the other dental alloys. Further improvements in castability and minimization of the surface reaction layer are needed for applications in dental prostheses.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. 1) Sherepo KM, Red’ko IA. The use of zirconium for implants in traumatology and orthopedics. Med Tekh 2004; 2: 22-24.
2. 2) Miyazaki T, Nakamura T, Matsumura H, Ban S, Kobayashi T. Current status of zirconia restoration. J Prosthodont Res 2013; 57: 236-261.10.1016/j.jpor.2013.09.001 ↗
3. 3) Millen CS, Reuben RL, Ibbetson RJ. The effect of coping/veneer thickness on the fracture toughness and residual stress of implant supported, cement retained zirconia and metal-ceramic crowns. Dent Mater 2006; 28: e250-258.10.1016/j.dental.2012.06.008 ↗
4. 4) Hosseini M, Kleven E, Gotfredsen K. Fracture mode during cyclic loading of implant-supported single-tooth restorations. J Prosthet Dent 2012; 108: 74-83.10.1016/S0022-3913(12)60110-3 ↗
5. 5) Han HS, Yang HS, Lim HP, Park YJ. Marginal accuracy and internal fit of machine-milled and cast titanium crowns. J Prosthet Dent 2011; 106: 191-197.10.1016/S0022-3913(11)60120-0 ↗
6. 6) Hjalmarsson L. On cobalt-chrome frameworks in implant dentistry. Swed Dent J Suppl 2009; 201: 3-83
7. 7) Hjalmarsson L, Smedberg JI, Pettersson M, Jemt T. Implantlevel prostheses in the edentulous maxilla: a comparison with conventional abutment-level prostheses after 5 years of use. Int J Prosthodont 2011; 24: 158-167.
8. 8) Yannikakis S, Prombonas A. Improving the fit of implant prosthetics: an in vitro study. Int J Oral Maxillofac Implants 2013; 1: 126-134.10.11607/jomi.2346 ↗
9. 9) Svanborg P, Längström L, Lundh RM, Bjerkstig G, Ortorp A. A 5-year retrospective study of cobalt-chromium-based fixed dental prostheses. Int J Prosthodont 2013; 26: 343-349.10.11607/ijp.3024 ↗
10. 10) Hashemi RH, Bradley WG. MRI: the basics, 1st ed. Baltimore: Williams & Wilkins; 1997
11. 11) Bennett LH, Wang PS, Donahue MJ. Artifacts in magnetic resonance imaging from metals. J Appl Phys 1996; 79: 4712-4714.10.1063/1.361649 ↗
12. 12) Shafiei F, Honda E, Takahashi H, Sasaki T. Artifacts from dental casting alloys in magnetic resonance imaging. J Dent Res 2003; 82: 602-606.10.1177/154405910308200806 ↗
13. 13) Matsuura H, Inoue T, Ogasawara K, Sasaki M, Konno H, Kuzu Y, Nishimoto H, Ogawa A. Quantitative analysis of magnetic resonance imaging susceptibility artifacts caused by neurosurgical biomaterials: comparison of 0.5, 1.5, and 3.0 Tesla magnetic fields. Neurol Med Chir (Tokyo) 2005; 45: 395-399.10.2176/nmc.45.395 ↗
14. 14) Stankiewicz J, Glanz B, Healy B, Arora A, Neema M, Benedict R. Brain MRI lesion load at 1.5 T and 3 T versus clinical status in multiple sclerosis. Neuroimaging 2011; 21: e50-56.10.1111/j.1552-6569.2009.00449.x ↗
15. 15) Schmitt F, Grosu D, Mohr C, Purdy D, Salem K, Scott KT, Stoeckel B. 3 Tesla MRI: successful results with higher field strengths. Radiologe 2004; 44: 31-47.
16. 16) Zhou F, Wang B, Qiu K, Li L, Lin J, Li H, Zheng Y. Microstructure, mechanical property, corrosion behavior, and in vitro biocompatibility of Zr-Mo alloys. Biomed Mater Res B Appl Biomater 2012;101:237-46.
17. 17) Suyalatu, Kondo R, Tsutsumi Y, Doi H, Nomura N, Hanawa T. Effects of phase constitution on magnetic susceptibility and mechanical properties of Zr-rich Zr-Mo alloys. Acta Biomater 2011; 7: 4259-4266.10.1016/j.actbio.2011.07.005 ↗
18. 18) Nomura N, Tanaka Y, Kondo R, Suyalatu, Tsutsumi Y. Effect of Phase constitution of Zr-Nb alloys on their magnetic susceptibilities. Mater Transac 2009; 10: 2466-2472.10.2320/matertrans.M2009187 ↗
19. 19) Suyalatu, Nomura N, Oya K, Tanaka Y, Kondo R, Doi H, Tsutsumi Y, Hanawa T. Microstructure and magnetic susceptibility of as-cast Zr-Mo alloys. Acta Biomater 2010; 6: 1033-1038.10.1016/j.actbio.2009.09.013 ↗
20. 20) Akahori T, Niinomi M, Nakai M, Tsutsumi H, Kondo Y, Hattori T, Fukui H. Mechanical Properties and Biocompatibilities of Zr-Nb System Alloys with Different Nb Contents for Biomedical Applications. J Jpn Inst Metals 2011; 75: 445-451.10.2320/jinstmet.75.445 ↗
21. 21) Kondo R, Nomura N, Suyalatu, Tsutsumi Y, Doi H, Hanawa T. Microstructure and mechanical properties of as-cast Zr-Nb alloys. Acta Biomater 2011; 7: 4278-4284.10.1016/j.actbio.2011.07.020 ↗
22. 22) Kondo R, Shimizu R, Nomura N, Doi H, Suyalatu, Tsutsumi Y, Hanawa T. Effect of cold rolling on the magnetic susceptibility of Zr-14Nb alloy. Acta Biomater 2013; 9: 5795-5801.10.1016/j.actbio.2012.10.046 ↗
23. 23) Eliopoulos D, Zinelis S, Papadopoulos T. The effect of investment material type on the contamination zone and mechanical properties of commercially pure titanium castings. J Prosthet Dent 2005; 96: 539-548.10.1016/j.prosdent.2005.09.017 ↗
24. 24) Cai Z, Nakajima H, Woldu M, Berglund A, Bergman M, Okabe T. In vitro corrosion resistance of titanium made using different fabrication methods. Biomaterials 1999; 20: 183-190.10.1016/S0142-9612(98)00160-4 ↗
25. 25) Koike M, Cai Z, Fujii H, Brezner M, Okabe T. Corrosion behavior of cast titanium with reduced surface reaction layer made by a face-coating method. Biomaterials 2003; 24: 4541-4549.10.1016/S0142-9612(03)00063-2 ↗
26. 26) Doi H, Yoneyama T, Kotake M, Okuno O, Hamanaka H. Influence of impurities on mechanical properties of titanium castings. J J Dent Mater 1991; 10: 844-849.
27. 27) Anusavice KJ, Cascone P. In: Anusavice KJ, editor. Phillips’science of dental materials. 11th ed. St. Louis: Saunders Co; 2003. p. 563-620.
28. 28) O’Brien WJ. Dental materials and their selection. 2nd ed. Chicago: Quintessence; 1997. p. 5-8
29. 29) Kikuchi H, Onouchi M, Miyanaga K, Wakashima M, Okuno O, Nishiyama M. The thickness effects of titanium castings on the surface reaction layer. Dent Mater J 2004; 23: 387-394.10.4012/dmj.23.387 ↗
30. 30) Guilin Y, Nan L, Yousheng L, Yining W. The effects of different types of investments on the alpha-case layer of titanium castings. J Prosthet Dent 2007; 97: 157-164.10.1016/j.prosdent.2007.01.005 ↗
31. 31) Cai Z, Bunce N, Nunn ME, Okabe T. Porcelain adherence to dental cast CP titanium: effects of surface modifications. Biomaterials 2001; 22: 979-986.10.1016/S0142-9612(00)00263-5 ↗
32. 32) Takahashi J, Kimura H, Lautenschlager E, Chern J, Moser J, Greener E. Casting pure titanium into commercial phosphate bonded SiO2 investment molds. J Dent Res 1999; 69: 1800-1805.10.1177/00220345900690120301 ↗
33. 33) Kikuchi H, Onouchi M, Hsu HC, Kurotani T, Nishiyama M. Titanium casting: the surface reaction layer of castings obtained using ultra-low-temperature molds. J Oral Sci 2001; 43: 27-33.10.2334/josnusd.43.27 ↗
34. 34) Wang T, Kobayashi E, Doi H, Yoneyama T. Castability of Ti6Al-7Nb alloy for dental casting. J Med Dent Sci 1999; 46: 13-19.
35. 35) Mimura H, Nakai A. Effects of Co, Mo and Cu on fluidity of 80Ni-20Cr alloy. J J Dent Mater 1989; 8: 231-241.
36. 36) Watanabe K, Okawa S. Relationship between titanium flow and casting contamination caused by mold materials. J J Dent Mater 1992; 11: 662-671.
37. 37) Paradis P, Ishikawa T, Yoda S. Non-contact measurements of surface tension and viscosity of niobium, zirconium, and titanium using an electrostatic levitation furnace. Int J Thermophys 2002; 23: 825-842.10.1023/A:1015459222027 ↗