journal article·2018Open access

Influence of grade and surface topography of commercially pure titanium on fatigue properties

Kaoru SUZUKI, Tomofumi TAKANO, Shinji TAKEMOTO, Takayuki UEDA, Masao YOSHINARI, Kaoru SAKURAI

Dental Materials Journal· Volume 37· Issue 2

Abstract

The objective was to investigate the influence of grade and surface topography of commercially pure titanium (Cp-Ti) on fatigue properties evaluated via staircase method. Cp-Ti grades 2 and 4 were roughened by shot blasting and acid etching, and compared with machined specimens. Yield force under static loading for Cp-Ti grades 2 and 4 were 672±51 and 1,088±93 N for machined and 724±99 and 1,118±96 N for roughened group. Yield force under cyclic loading for Cp-Ti grades 2 and 4 decreased 27 and 40% compared to static loading. Cp-Ti grade 4 demonstrated significantly greater decrease in yield force after cyclic loading; however surface topography had no effect.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Removable Prosthodontics and Gerodontology, Tokyo Dental College

Oral Health Science Center, Tokyo Dental College

Department of Dental Materials Science, Tokyo Dental College

References (39)

Show source-provided references
1. 1) Goodacre CJ, Bernal G, Rungcharassaeng K, Kan JYK. Clinical complications with implants and implant prostheses. J Prosthet Dent 2003; 90: 121-132.10.1016/S0022-3913(03)00212-9 ↗
2. 2) Eckert SE, Meraw SJ, Cal E, Ow RK. Analysis of incidence and associated factors with fractured implants: a retrospective study. Int J Oral Maxillofac Implants 2000; 15: 662-667.
3. 3) Morgan MJ, James DF, Pilliar RM. Fractures of the fixture component of an osseointegrated implant. Int J Oral Maxillofac Implants 1993; 8: 409-414.
4. 4) ISO 5832-2. Implants For Surgery —Metallic Materials— Part 2: Unalloyed Titanium1999.
5. 5) Katakura A, Shibahara T, Noma H, Yoshinari M. Material analysis of AO plate fracture cases. J Oral Maxillofac Surg 2004; 62: 348-352.10.1016/j.joms.2003.05.009 ↗
6. 6) Yoshinari M, Matsuzaka K, Inoue T. Surface modification by cold-plasma technique for dental implants-Bio-functionalization with binding pharmaceuticals. Jpn Dent Sci Rev 2011; 47: 89-101.10.1016/j.jdsr.2011.03.001 ↗
7. 7) Duraccio D, Mussano F, Faga MG. Biomaterials for dental implants: current and future trends. J Mater Sci 2015; 50: 4779-4812.10.1007/s10853-015-9056-3 ↗
8. 8) Cochran DL, Schenk RK, Lussi A, Higginbottom FL, Buser D.Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: a histometric study in the canine mandible. J Biomed Mater Res 1998; 40: 1-11.10.1002/(SICI)1097-4636(199804)40:1<1::AID-JBM1>3.0.CO;2-Q ↗
9. 9) Buser D, Nydegger T, Oxland T, Cochran DL, Schenk RK, Hirt HP, Snétivy D, Nolte LP. Interface shear strength of titanium implants with a sandblasted and acid-etched surface: a biomechanical study in the maxilla of miniature pigs. J Biomed Mater Res 1999; 45: 75-83.10.1002/(SICI)1097-4636(199905)45:2<75::AID-JBM1>3.0.CO;2-P ↗
10. 10) Buser D, Nydegger T, Hirt HP, Cochran DL, Nolte LP. Removal torque values of titanium implants in the maxilla of miniature pigs. Int J Oral Maxillofac Implants 1998; 13: 611-619.
11. 11) Zinger O, Anselme K, Denzer A, Habersetzer P, Wieland M, Jeanfils J, Hardouin P, Landolt D. Time-dependent morphology and adhesion of osteoblastic cells on titanium model surfaces featuring scale-resolved topography. Biomaterials 2004; 25: 2695-2711.10.1016/j.biomaterials.2003.09.111 ↗
12. 12) Das K, Bose S, Bandyopadhyay A. TiO2 nanotubes on Ti: Influence of nanoscale morphology on bone cell-materials interaction. J Biomed Mater Res A 2009; 90: 225-237.10.1002/jbm.a.32088 ↗
13. 13) Kubo K, Tsukimura N, Iwasa F, Ueno T, Saruwatari L, Aita H, Chiou WA, Ogawa T. Cellular behavior on TiO2 nanonodular structures in a micro-to-nanoscale hierarchy model. Biomaterials 2009; 30: 5319-5329.10.1016/j.biomaterials.2009.06.021 ↗
14. 14) Hirano T, Sasaki H, Honma S, Furuya Y, Miura T, Yajima Y, Yoshinari M. Proliferation and osteogenic differentiation of human mesenchymal stem cells on zirconia and titanium with different surface topography. Dent Mater J 2015; 34: 872-880.10.4012/dmj.2015-129 ↗
15. 15) Marinucci L, Balloni S, Becchetti E, Belcastro S, Guerra M, Calvitti M, Lilli C, Calvi EM, Locci P. Effect of titanium surface roughness on human osteoblast proliferation and gene expression in vitro. Int J Oral Maxillofac Implants 2006; 21: 719-725.
16. 16) Gil FJ, Planell JA, Padros A. Fracture and fatigue behavior of shot-blasted titanium dental implants. Implant Dent 2002; 11: 28-32.10.1097/00008505-200201000-00011 ↗
17. 17) Pazos L, Corengia P, Svoboda H. Effect of surface treatments on the fatigue life of titanium for biomedical applications. J Mech Behav Biomed Mater 2010; 3: 416-424.10.1016/j.jmbbm.2010.03.006 ↗
18. 18) Ketabchi A, Weck A, Variola F. Influence of oxidative nanopatterning and anodization on the fatigue resistance of commercially pure titanium and Ti-6Al-4V. J Biomed Mater Res B Appl Biomater 2015; 103: 563-571.10.1002/jbm.b.33227 ↗
19. 19) Koyama T, Sato T, Yoshinari M. Cyclic fatigue resistance of yttria-stabilized tetragonal zirconia polycrystals with hot isostatic press processing. Dent Mater J 2012; 31: 1103-1110.10.4012/dmj.2012-246 ↗
20. 20) Leinenbach C, Eifler D. Influence of oxidation treatment on fatigue and fatigue-induced damage of commercially pure titanium. Acta Biomater 2009; 5: 2810-2819.10.1016/j.actbio.2009.03.029 ↗
21. 21) Leinenbach C, Eifler D. Fatigue and cyclic deformation behaviour of surface-modified titanium alloys in simulated physiological media. Biomaterials 2006; 27: 1200-1208.10.1016/j.biomaterials.2005.08.012 ↗
22. 22) ISO 14801: 2007. Dentistry —Implants— Dynamic Fatigue Test For Endosseous Dental Implants 2007.
23. 23) Elias CN, Fernandes DJ, Resende CR, Roestel J. Mechanical properties, surface morphology and stability of a modified commercially pure high strength titanium alloy for dental implants. Dent Mater 2015; 31: e1-e13.10.1016/j.dental.2014.10.002 ↗
24. 24) Jo JY, Yang DS, Huh JB, Heo JC, Yun MJ, Jeong CM. Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems. J Adv Prosthodont 2014; 6: 491-497.10.4047/jap.2014.6.6.491 ↗
25. 25) Allum SR, Tomlinson RA, Joshi R. The impact of loads on standard diameter, small diameter and mini implants: a comparative laboratory study. Clin Oral Implants Res 2008; 19: 553-559.10.1111/j.1600-0501.2007.01395.x ↗
26. 26) Muhlemann S, Truninger TC, Stawarczyk B, Hammerle CH, Sailer I. Bending moments of zirconia and titanium implant abutments supporting all-ceramic crowns after aging. Clin Oral Implants Res 2014; 25: 74-81.10.1111/clr.12192 ↗
27. 27) Marchetti E, Ratta S, Mummolo S, Tecco S, Pecci R, Bedini R, Marzo G. Evaluation of an endosseous oral implant system according to UNI EN ISO 14801 fatigue test protocol. Implant Dent 2014; 23: 665-671.10.1097/ID.0000000000000151 ↗
28. 28) Collins J.A. Failure of materials in Dynamic mechanical design: Analysis, Prediction, Prevention. In: Collins J.A., editor. New York: A Wiley-Interscience publication.; 1981. p. 360-378.
29. 29) Akahori T, Niinomi M, Fukui H, Ogawa M, Toda H. Improvement in fatigue characteristics of newly developed beta type titanium alloy for biomedical applications by thermo-mechanical treatments. Mater Sci Eng C 2005; 25: 248-254.10.1016/j.msec.2004.12.007 ↗
30. 30) Song X, Wang L, Niinomi M, Nakai M, Liu Y. Fatigue characteristics of a biomedical β-type titanium alloy with titanium boride. Mater Sci Eng A 2015; 640: 154-164.10.1016/j.msea.2015.05.078 ↗
31. 31) Takano T, Tasaka A, Yoshinari M, Sakurai K. Fatigue strength of Ce-TZP/Al2O3 nanocomposite with different surfaces. J Dent Res 2012; 91: 800-804.10.1177/0022034512452277 ↗
32. 32) Bauer S, Schmuki P, von der Mark K, Park J. Engineering biocompatible implant surfaces: Part I: Materials and surfaces. Prog Mater Sci 2013; 58: 261-326.10.1016/j.pmatsci.2012.09.001 ↗
33. 33) Guilherme AS, Henriques GE, Zavanelli RA, Mesquita MF. Surface roughness and fatigue performance of commercially pure titanium and Ti-6Al-4V alloy after different polishing protocols. J Prosthet Dent 2005; 93: 378-385.10.1016/j.prosdent.2005.01.010 ↗
34. 34) Iijima T, Homma S, Sekine H, Sasaki H, Yajima Y, Yoshinari M.Influence of surface treatment of yttria-stabilized tetragonal zirconia polycrystal with hot isostatic pressing on cyclic fatigue strength. Dent Mater J 2013; 32: 274-280.10.4012/dmj.2012-247 ↗
35. 35) Yokoyama K, Ichikawa T, Murakami H, Miyamoto Y, Asaoka K.Fracture mechanisms of retrieved titanium screw thread in dental implant. Biomaterials 2002; 23: 2459-2465.10.1016/S0142-9612(01)00380-5 ↗
36. 36) Sripetchdanond J, Leevailoj C. Wear of human enamel opposing monolithic zirconia, glass ceramic, and composite resin: An in vitro study. J Prosthet Dent 2014; 112: 1141-1150.10.1016/j.prosdent.2014.05.006 ↗
37. 37) Thoma DS, Jones AA, Dard M, Grize L, Obrecht M, Cochran DL. Tissue integration of a new titanium-zirconium dental implant: a comparative histologic and radiographic study in the canine. J Periodontol 2011; 82: 1453-1461.10.1902/jop.2010.100737 ↗
38. 38) Chiapasco M, Casentini P, Zaniboni M, Corsi E, Anello T.Titanium-zirconium alloy narrow-diameter implants (Straumann Roxolid®) for the rehabilitation of horizontally deficient edentulous ridges: prospective study on 18 consecutive patients. Clin Oral Implants Res 2012; 23: 1136-1141.10.1111/j.1600-0501.2011.02296.x ↗
39. 39) Gottlow J, Dard M, Kjellson F, Obrecht M, Sennerby L. Evaluation of a new titanium-zirconium dental implant: a biomechanical and histological comparative study in the mini pig. Clin Implant Dent Relat Res 2012; 14: 538-545.10.1111/j.1708-8208.2010.00289.x ↗