journal article·2014Open access

In vitro evaluation of marginal and internal adaptation of three-unit fixed dental prostheses produced by stereolithography

Ki-Baek KIM, Jae-Hong KIM, Woong-Chul KIM, Ji-Hwan KIM

Dental Materials Journal· Volume 33· Issue 4

Abstract

The purpose of this study was to investigate, by measuring the gap, the possible clinical use of three-unit fixed dental prostheses (FDPs) manufactured using stereolithography. A total of 20 epoxy models were built with a same case (abutment teeth 14, 16). The 40 specimens were produced using the stereolithography (SLA) and wax-up (LW). The 960 gaps of the 40 specimens produced were measured by a silicone replica. The Wilcoxon rank sum test was then used to compare and analyze the data obtained from the two groups (α=0.05). The total gap, as measured from the SLA and LW groups, was 98.6 and 66.6 µm, respectively. The results indicate that the gap in the SLA group is statistically significantly greater than that in the LW group (p<0.05). Further assessment and improvement of the SLA method for the fabrication of FDPs is evidently still required.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Dental Research and COVID-19

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (22)

Show source-provided references
1. 1) Conrad HJ, Seong WJ, Pesun IJ. Current ceramic materials and systems with clinical recommendations: a systematic review. J Prosthet Dent 2007; 98: 389-404.10.1016/S0022-3913(07)60124-3 ↗
2. 2) Miyazaki T, Hotta Y, Kunii J, Kuriyama S, Tamaki Y. A review of dental CAD/CAM: currentstatus and futureperspectives from 20 years of experience. Dent Mater J 2009; 28: 44-56.10.4012/dmj.28.44 ↗
3. 3) Petteno D, Schierano G, Bassi F, Bresciano ME, Carossa S. Comparison of marginal fit of 3 different metal-ceramic systems: an in vitro study. Int J Prosthodont 2000; 13: 405-408.
4. 4) Strub JR, Rekow ED, Witkowski S. Computer-aided design and fabrication of dental restorations: current systems and future possibilities. J Am Dent Assoc 2006; 137: 1289-1296.10.14219/jada.archive.2006.0389 ↗
5. 5) van Noort R. The future of dental devices is digital. Dent Mater 2012; 28: 3-12.10.1016/j.dental.2011.10.014 ↗
6. 6) Vigolo P, Fonzi F. An in vitro evaluation of fit of zirconiumoxide-based ceramic four-unit fixed partial dentures, generated with three different CAD/CAM systems, before and after porcelain firing cycles and after glaze cycles. J Prosthodont 2008; 17: 621-626.10.1111/j.1532-849X.2008.00366.x ↗
7. 7) Foster LV. Failed conventional bridge work from general dental practice: clinical aspects and treatment needs of 142 cases. Br Dent J 1990; 168: 199-201.10.1038/sj.bdj.4807133 ↗
8. 8) Yucel MT, Aykent F, Avunduk MC. In vitro evaluation of the marginal fit of different all-ceramic crowns. J Dent Sci 2012; 9: 188-194.
9. 9) Ucar Y, Akova T, Akyil MS, Brantley WA. Internal fit evaluation of crowns prepared using a new dental crown fabrication technique: laser-sintered Co-Cr crowns. J Prosthet Dent 2009; 102: 253-259.10.1016/S0022-3913(09)60165-7 ↗
10. 10) Quante K, Ludwig K, Kern M. Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology. Dent Mater 2008; 24: 1311-1315.10.1016/j.dental.2008.02.011 ↗
11. 11) Örtorp A, Jönsson D, Mouhsen A, Vult von Steyern P. The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: A comparative in vitro study. Dent Mater 2011; 27: 356-363.10.1016/j.dental.2010.11.015 ↗
12. 12) Cho SH, Chang WG, Lim BS, Lee YK. Effect of die spacer thickness on shear bond strength of porcelain laminate veneers. J Prosthet Dent 2006; 95: 201-208.10.1016/j.prosdent.2005.12.011 ↗
13. 13) Kokubo Y, Tsumita M, Kano T, Sakurai S, Fukushima S. Clinical marginal and internal gaps of zirconia all-ceramic crowns. J Prosthodont Res 2011; 55: 40-43.10.1016/j.jpor.2010.09.001 ↗
14. 14) Holmes JR, Bayne SC, Holland GA, Sulik WD. Considerations in measurement of marginal fit. J Prosthet Dent 1989; 62: 405-408.10.1016/0022-3913(89)90170-4 ↗
15. 15) Laurent M, Scheer P, Dejou J, Laborde G. Clinical evaluation of the marginal fit of cast crowns —validation of the silicone replica method. J Oral Rehabil 2008; 35: 116-122.10.1111/j.1365-2842.2003.01203.x ↗
16. 16) Rahme HY, Tehini GE, Adib SM, Ardo AS, Rifai KT. In vitro evaluation of the ‘‘replica technique’’ in the measurement of the fit of Procera crowns. J Contemp Dent Pract 2008; 9: 25-32.
17. 17) Harris IR, Wickens JL. A comparison of the fit of sparkeroded titanium copings and cast gold alloy copings.Int J Prosthodont 1994; 7: 348-355.
18. 18) Yildiz C, Vanlioğlu BA, Evren B, Uludamar A, Ozkan YK. Marginal-internal adaptation and fracture resistance of CAD/CAM crown restorations. Dent Mater J 2013; 32: 42-47.10.4012/dmj.2012-148 ↗
19. 19) McLean JW, von Frauenhofer JA. The estimation of cementfilm thickness by an in vivo technique.Br Dent J 1971; 131: 107-111.10.1038/sj.bdj.4802708 ↗
20. 20) Ostlund LE. Cavity design and mathmatics: their effect ongaps at the margins of cast restorations. Oper Dent 1985; 10: 122-137.
21. 21) Moldovan O, Rudolph H, Quaas S, Bornemann G, Lurthardt RG. Internal and external fit of CAM-madezirconia bridge frameworks —a pilot study. DtschZahnärztl Z 2006; 61: 38-42.
22. 22) Beuer F, Aggstaller H, Edelhoff D, Gernet W, Sorensen J. Marginal and internal fits of fixed dental prostheses zirconia retainers. Dent Mater 2009; 25: 94-102.10.1016/j.dental.2008.04.018 ↗