Nanodiamonds stabilized in dihexadecyl phosphate film for electrochemical study and quantification of codeine in biological and pharmaceutical samples
Source abstract
Abstract
Abstract A new architecture for a sensor and a voltammetric procedure were proposed, using a glassy carbon electrode modified with nanodiamonds and dihexadecyl phosphate for determination of codeine (COD) in pharmaceutical and biological fluid samples. Square-wave voltammetry (SWV) was used and the relevant experimental parameters were optimized. Under optimal experimental conditions, the analytical curve presented a linear concentration range from 0.299 to 10.8 μmol L −1 , and a limit of detection of 54.5 nmol L − 1 . The proposed voltammetric method was used for COD determination in commercial pharmaceutical and biological fluid samples such as urine and human serum with satisfactory results.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Electrochemical sensors and biosensors · Diamond and Carbon-based Materials Research · Analytical Chemistry and Sensors
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (49)
Show source-provided references
1. Amperometric glucose sensor based on catalytic reduction of dissolved oxygen at soluble carbon nanofiber10.1016/j.bios.2007.06.009 ↗
2. Direct electron transfer of glucose oxidase promoted by carbon nanotubes10.1016/j.ab.2004.05.057 ↗
3. Electrocatalysis at graphite and carbon nanotube modified electrodes: edge-plane sites and tube ends are the reactive sites10.1039/b413177k ↗
4. Voltammetric determination of verapamil and propranolol using a glassy carbon electrode modified with functionalized multiwalled carbon nanotubes within a poly (allylamine hydrochloride) film10.1016/j.jelechem.2013.09.016 ↗
5. Planejamento fatorial e superfície de resposta: otimização de um método voltamétrico para a determinação de Ag(I) empregando um eletrodo de pasta de nanotubos de carbono
6. Exploring the electrochemical performance of graphitic paste electrodes: graphene vs. graphite10.1039/c3an00950e ↗
7. Carbon black-modified screen-printed electrodes as electroanalytical tools10.1002/elan.201100561 ↗
8. Hg2+ detection by measuring thiol groups with a highly sensitive screen-printed electrode modified with a nanostructured carbon black film10.1016/j.electacta.2011.01.094 ↗
9. Synergistic contributions of fullerene, ferrocene, chitosan and ionic liquid towards improved performance for a glucose sensor10.1016/j.bios.2009.10.045 ↗
10. Enhanced electrochemical response of carbamazepine at a nano-structured sensing film of fullerene-C60 and its analytical applications10.1016/j.electacta.2010.08.071 ↗
11. Application of carbon nanoparticle/chitosan modified electrode for the square-wave adsorptive anodic striping voltammetric determination of Niclosamide10.1016/j.elecom.2009.10.037 ↗
12. Potentiometric stripping analysis of methyl and ethyl parathion employing carbon nanoparticles and halloysite nanoclay modified carbon paste electrode10.1016/j.aca.2012.05.029 ↗
13. Pyrolytic graphite electrode modified with a thin film of a graphite/diamond nano-mixture for highly sensitive voltammetric determination of tryptophan and 5-hydroxytryptophan10.1007/s00604-011-0631-2 ↗
14. Diamonds in detonation soot10.1038/333440a0 ↗
15. Electrochemical properties of nanodiamond powder electrodes10.1016/j.diamond.2006.03.010 ↗
16. Electrochemical synthesis of polyaniline on nanodiamond powder10.1016/S1452-3981(23)13444-4 ↗
17. Glassy carbon electrodes modified with a film of nanodiamond–graphite/chitosan: application to the highly sensitive electrochemical determination of Azathioprine10.1016/j.electacta.2010.01.099 ↗
18. Electrochemistry of carboxylated nanodiamond films10.1007/s11426-012-4619-5 ↗
19. Nanodiamond films for applications in electrochemical systems and aeronautics and space technology10.1590/S0100-40422006000100023 ↗
20. Diamond electrochemistry at the nanoscale: a review10.1016/j.carbon.2015.11.061 ↗
21. Application of pyrolytic graphite modified with nano-diamond/graphite film for simultaneous voltammetric determination of epinephrine and uric acid in the presence of ascorbic acid10.1016/j.electacta.2010.08.043 ↗
22. Sensitive determination of hydrogen peroxide based on a novel nonenzymatic electrochemical sensor: silver nanoparticles decorated on nanodiamonds10.1007/s13738-015-0611-2 ↗
23. The use of dihexadecylphosphate in sensing and biosensing10.1016/j.snb.2015.06.020 ↗
24. Determination of gemfibrozil in pharmaceutical and urine samples by square-wave adsorptive stripping voltammetry using a glassy carbon electrode modified with multi-walled carbon nanotubes within a dihexadecyl hydrogen phosphate film10.1016/j.jelechem.2012.11.038 ↗
25. Square-wave voltammetric determination of paraquat using a glassy carbon electrode modified with multiwalled carbon nanotubes within a dihexadecylhydrogenphosphate (DHP) film10.1016/j.snb.2013.01.091 ↗
26. Tyrosinase biosensor based on a glassy carbon electrode modified with multi-walled carbon nanotubes and 1-butyl-3-methylimidazolium chloride within a dihexadecylphosphate film10.1016/j.snb.2013.07.109 ↗
27. Screen-printed biosensor based on the inhibition of the acetylcholinesterase activity for the determination of codeine10.1016/j.talanta.2013.03.042 ↗
28. Electrochemical behavior of codeine and its sensitive determination on graphene-based modified electrode10.1016/j.snb.2013.03.023 ↗
29. Rapid and sensitive electrochemical determination of codeine in pharmaceutical formulations and human urine using a boron-doped diamond film electrode10.1016/j.electacta.2012.09.111 ↗
30. A new electrochemical sensor for the simultaneous determination of acetaminophen and codeine based on porous silicon/palladium nanostructure10.1016/j.talanta.2014.12.028 ↗
31. Determination of morphine and codeine in human urine by gas chromatography-mass spectrometry10.1155/2013/151934 ↗
32. Gas chromatographic-mass spectrometric procedures used for the identification and determination of morphine, codeine and 6-monoacetylmorphine10.1016/0021-9673(94)85227-8 ↗
33. A validated method for simultaneous determination of codeine, codeine-6-glucuronide, norcodeine, morphine, morphine-3-glucuronide and morphine-6-glucuronide in post-mortem blood, vitreous fluid, muscle, fat and brain tissue by LC-MS10.1093/jat/bku145 ↗
34. Multi-drug and metabolite quantification in postmortem blood by liquid chromatography-high-resolution mass spectrometry: comparison with nominal mass technology10.1093/jat/bku066 ↗
35. Pb(II) determination in natural water using a carbon nanotubes paste electrode modified with crosslinked chitosan10.1016/j.microc.2014.05.008 ↗
36. Electrochemical determination of rosuvastatin calcium in pharmaceutical and human body fluid samples using a composite of vertically aligned carbon nanotubes and graphene oxide as the electrode material10.1016/j.snb.2015.04.085 ↗
37. Application of liquid chromatography to the simultaneous determination of acetylsalicylic acid, caffeine, codeine, paracetamol, pyridoxine, and thiamine in pharmaceutical preparations.10.1093/jaoac/84.3.676 ↗
38. Laser-probe-based investigation of the evolution of particle size distributions of calcium oxalate particles formed in artificial urines10.1016/S0022-0248(01)01547-0 ↗
39. Determination of isosorbide dinitrate in arterial plasma, synthetic serum and pharmaceutical formulations by linear sweep voltammetry on a gold electrode10.1016/S0039-9140(01)00416-7 ↗
40. Chemical modifications and stability of diamond nanoparticles resolved by infrared spectroscopy and Kelvin force microscopy10.1007/s11051-013-1568-7 ↗
41. Determination of impurities in detonation nanodiamonds by gamma activation analysis method10.1016/j.diamond.2015.03.010 ↗
42. Surface functionalization and structure characterizations of nanodiamond and its epoxy based nanocomposites10.1016/j.compositesb.2015.04.012 ↗
43. Surface modification and stability of detonation nanodiamonds in microwave gas discharge plasma10.1016/j.apsusc.2015.09.251 ↗
44. Redox properties of undoped 5 nm diamond nanoparticles10.1039/B711049A ↗
45. An electrochemical sensor for the simultaneous determination of paracetamol and codeine using a glassy carbon electrode modified with nickel oxide nanoparticles and carbon black10.1002/elan.201500156 ↗
46. Simultaneous determination of codeine and caffeine using single-walled carbon nanotubes modified carbon-ceramic electrode10.1016/j.colsurfb.2013.09.026 ↗
47. Square-wave voltammetric determination of paracetamol and codeine in pharmaceutical and human body fluid samples using a cathodically pretreated boron-doped diamond electrode
48. Voltammetric determination of codeine on glassy carbon electrode modified with nafion/MWCNTs10.1155/2015/626458 ↗
49. Simultaneous determination of morphine and codeine using Pt nanoparticles supported on porous silicon flour modified ionic liquid carbon paste electrode10.1016/j.snb.2015.05.010 ↗