Research progress of loop-mediated isothermal amplification in the detection of Salmonella for food safety applications
Source abstract
Abstract
Salmonella, the prevailing zoonotic pathogen within the Enterobacteriaceae family, holds the foremost position in global bacterial poisoning incidents, thereby signifying its paramount importance in public health. Consequently, the imperative for expeditious and uncomplicated detection techniques for Salmonella in food is underscored. After more than two decades of development, loop-mediated isothermal amplification (LAMP) has emerged as a potent adjunct to the polymerase chain reaction, demonstrating significant advantages in the realm of isothermal amplification. Its growing prominence is evident in the increasing number of reports on its application in the rapid detection of Salmonella. This paper provides a systematic exposition of the technical principles and characteristics of LAMP, along with an overview of the research progress made in the rapid detection of Salmonella using LAMP and its derivatives. Additionally, the target genes reported in various levels, including Salmonella genus, species, serogroup, and serotype, are summarized, aiming to offer a valuable reference for the advancement of LAMP application in Salmonella detection. Finally, we look forward to the development direction of LAMP and expect more competitive methods to provide strong support for food safety applications.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Biosensors and Analytical Detection · Identification and Quantification in Food · Listeria monocytogenes in Food Safety
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (100+)
Show source-provided references
1. Kirk MD, Pires SM, Black RE, Caipo M, Crump JA, Devleesschauwer B, Döpfer D, Fazil A, Fischer-Walker CL, Hald T, Hall AJ, Keddy KH, Lake RJ, Lanata CF, Torgerson PR, Havelaar AH, Angulo FJ. World Health Organization estimates of the global and regional disease burden of 22 foodborne bacterial, protozoal, and viral diseases, 2010: a data synthesis. PLoS Med. 2015;12: e1001921. https://doi.org/10.1371/journal.pmed.1001921.10.1371/journal.pmed.1001921 ↗
2. Carroll LM, Wiedmann M, den Bakker H, Siler J, Warchocki S, Kent D, Lyalina S, Davis M, Sischo W, Besser T, Warnick LD, Pereira RV. Whole-Genome Sequencing of drug-resistant Salmonella enterica isolates from dairy cattle and humans in New York and Washington states reveals source and geographic associations. Appl Environ Microbiol. 2017;83:e00140-17. https://doi.org/10.1128/AEM.00140-17.10.1128/AEM.00140-17 ↗
3. European Food Safety Authority (EFSA). Microbiological risk assessment in feedingstuffs for food-producing animals - scientific opinion of the panel on biological hazards. EFSA J. 2008;6:720. https://doi.org/10.2903/j.efsa.2008.720.10.2903/j.efsa.2008.720 ↗
4. Uzzau S, Brown DJ, Wallis T, Rubino S, Leori G, Bernard S, Casadesús J, Platt DJ, Olsen JE. Host adapted serotypes of Salmonella enterica. Epidemiol Infect. 2000;125:229–55. https://doi.org/10.1017/s0950268899004379.10.1017/s0950268899004379 ↗
5. Lamas A, Miranda JM, Regal P, Vázquez B, Franco CM, Cepeda A. A comprehensive review of non-enterica subspecies of Salmonella enterica. Microbiol Res. 2018;206:60–73. https://doi.org/10.1016/j.micres.2017.09.010.10.1016/j.micres.2017.09.010 ↗
6. Fitzgerald C, Collins M, van Duyne S, Mikoleit M, Brown T, Fields P. Multiplex, bead-based suspension array for molecular determination of common Salmonella serogroups. J Clin Microbiol. 2007;45:3323–34. https://doi.org/10.1128/JCM.00025-07.10.1128/JCM.00025-07 ↗
7. Zhang P, Zhuang L, Zhang D, Dong Y, Sheng Z, Wang C, Xu B, Dou X, Gong J. Research progress on molecular detection methods of Salmonella. Acta Veterinaria et Zootechnica Sinica. 2023;54:3217–29. https://doi.org/10.11843/j.issn.0366-6964.2023.08.009.10.11843/j.issn.0366-6964.2023.08.009 ↗
8. Mooijman KA, Pielaat A, Kuijpers AFA. Validation of EN ISO 6579–1 - Microbiology of the food chain - horizontal method for the detection, enumeration and serotyping of Salmonella - Part 1 detection of Salmonella spp. Int J Food Microbiol. 2019;288:3–12. https://doi.org/10.1016/j.ijfoodmicro.2018.03.022.10.1016/j.ijfoodmicro.2018.03.022 ↗
9. Gu K, Song Z, Zhou C, Ma P, Li C, Lu Q, Liao Z, Huang Z, Tang Y, Li H, Zhao Y, Yan W, Lei C, Wang H. Development of nanobody-horseradish peroxidase-based sandwich ELISA to detect Salmonella Enteritidis in milk and in vivo colonization in chicken. J Nanobiotechnol. 2022;20:167. https://doi.org/10.1186/s12951-022-01376-y.10.1186/s12951-022-01376-y ↗
10. Sahu B, Singh SD, Behera BK, Panda SK, Das A, Parida PK. Rapid detection of Salmonella contamination in seafoods using multiplex PCR. Braz J Microbiol. 2019;50:807–16. https://doi.org/10.1007/s42770-019-00072-8.10.1007/s42770-019-00072-8 ↗
11. Yang Q, Domesle KJ, Ge B. Loop-mediated isothermal amplification for Salmonella detection in food and feed: current applications and future directions. Foodborne Pathog Dis. 2018;15:309–31. https://doi.org/10.1089/fpd.2018.2445.10.1089/fpd.2018.2445 ↗
12. Li X, Zheng T, Xie Y-N, Li F, Jiang X, Hou X, Wu P. Recombinase polymerase amplification coupled with a photosensitization colorimetric assay for fast Salmonella spp. testing. Anal Chem. 2021;93:6559–66. https://doi.org/10.1021/acs.analchem.1c00791.10.1021/acs.analchem.1c00791 ↗
13. Xue T, Lu Y, Yang H, Hu X, Zhang K, Ren Y, Wu C, Xia X, Deng R, Wang Y. Isothermal RNA amplification for the detection of viable pathogenic bacteria to estimate the Salmonella virulence for causing enteritis. J Agric Food Chem. 2022;70:1670–8. https://doi.org/10.1021/acs.jafc.1c07182.10.1021/acs.jafc.1c07182 ↗
14. Yeap CSY, Chaibun T, Lee SY, Zhao B, Jan Y, La-O-Vorakiat C, Surareungchai W, Song S, Lertanantawong B. Ultrasensitive pathogen detection with a rolling circle amplification-empowered multiplex electrochemical DNA sensor. Chem Commun (Camb). 2021;57:12155–8. https://doi.org/10.1039/d1cc05181d.10.1039/d1cc05181d ↗
15. Xu W, Gao J, Zheng H, Yuan C, Hou J, Zhang L, Wang G. Establishment and application of polymerase spiral reaction amplification for Salmonella detection in food. J Microbiol Biotechnol. 2019;29:1543–52. https://doi.org/10.4014/jmb.1906.06027.10.4014/jmb.1906.06027 ↗
16. Notomi T, Okayama H, Masubuchi H, Yonekawa T, Watanabe K, Amino N, Hase T. Loop-mediated isothermal amplification of DNA. Nucleic Acids Res. 2000;28:E63. https://doi.org/10.1093/nar/28.12.e63.10.1093/nar/28.12.e63 ↗
17. Nagamine K, Hase T, Notomi T. Accelerated reaction by loop-mediated isothermal amplification using loop primers. Mol Cell Probes. 2002;16:223–9. https://doi.org/10.1006/mcpr.2002.0415.10.1006/mcpr.2002.0415 ↗
18. Ohtsuka K, Yanagawa K, Takatori K, Hara-Kudo Y. Detection of Salmonella enterica in naturally contaminated liquid eggs by loop-mediated isothermal amplification, and characterization of Salmonella isolates. Appl Environ Microbiol. 2005;71:6730–5. https://doi.org/10.1128/AEM.71.11.6730-6735.2005.10.1128/AEM.71.11.6730-6735.2005 ↗
19. Domesle KJ, Young SR, Yang Q, Ge B. Loop-mediated isothermal amplification for screening Salmonella in animal food and confirming Salmonella from culture isolation. J Vis Exp. 2020. https://doi.org/10.3791/61239.10.3791/61239 ↗
20. Domesle KJ, Young SR, Ge B. Rapid screening for Salmonella in raw pet food by loop-mediated isothermal amplification. J Food Prot. 2021;84:399–407. https://doi.org/10.4315/JFP-20-365.10.4315/JFP-20-365 ↗
21. Waldman J, Souza MN, Fonseca ASK, Ikuta N, Lunge VR. Direct detection of Salmonella from poultry samples by DNA isothermal amplification. Br Poult Sci. 2020;61:653–9. https://doi.org/10.1080/00071668.2020.1808188.10.1080/00071668.2020.1808188 ↗
22. Williams MR, Hashsham SA. Direct or DNA extraction-free amplification and quantification of foodborne pathogens. Methods Mol Biol. 2019;1918:21–33. https://doi.org/10.1007/978-1-4939-9000-9_2.10.1007/978-1-4939-9000-9_2 ↗
23. Bhadra S, Riedel TE, Lakhotia S, Tran ND, Ellington AD. High-surety isothermal amplification and detection of SARS-CoV-2. mSphere. 2021;6:e00911-20. https://doi.org/10.1128/mSphere.00911-20.10.1128/mSphere.00911-20 ↗
24. Garrido-Maestu A, Azinheiro S, Carvalho J, Abalde-Cela S, Carbó-Argibay E, Diéguez L, Piotrowski M, Kolen’ko YV, Prado M. Combination of microfluidic loop-mediated isothermal amplification with gold nanoparticles for rapid detection of Salmonella spp. in food samples. Front Microbiol. 2017;8:2159. https://doi.org/10.3389/fmicb.2017.02159.10.3389/fmicb.2017.02159 ↗
25. Jomoui W, Srivorakun H, Chansai S, Fucharoen S. Loop-mediated isothermal amplification (LAMP) colorimetric phenol red assay for rapid identification of α0-thalassemia: application to population screening and prenatal diagnosis. PLoS ONE. 2022;17:e0267832. https://doi.org/10.1371/journal.pone.0267832.10.1371/journal.pone.0267832 ↗
26. Wen J, Gou H, Zhan Z, Gao Y, Chen Z, Bai J, Wang S, Chen K, Lin Q, Liao M, Zhang J. A rapid novel visualized loop-mediated isothermal amplification method for Salmonella detection targeting at fimW gene. Poult Sci. 2020;99:3637–42. https://doi.org/10.1016/j.psj.2020.03.045.10.1016/j.psj.2020.03.045 ↗
27. Wang Y, Dai J, Liu Y, Yang J, Hou Q, Ou Y, Ding Y, Ma B, Chen H, Li M, Sun Y, Zheng H, Zhang K, Wubshet AK, Zaberezhny AD, Aliper TI, Tarasiuk K, Pejsak Z, Liu Z, Zhang Y, Zhang J. Development of a potential penside colorimetric LAMP assay using neutral red for detection of African swine fever virus. Front Microbiol. 2021;12: 609821. https://doi.org/10.3389/fmicb.2021.609821.10.3389/fmicb.2021.609821 ↗
28. Fischbach J, Xander NC, Frohme M, Glökler JF. Shining a light on LAMP assays–a comparison of LAMP visualization methods including the novel use of berberine. Biotechniques. 2015;58:189–94. https://doi.org/10.2144/000114275.10.2144/000114275 ↗
29. Parida MM, Santhosh SR, Dash PK, Tripathi NK, Lakshmi V, Mamidi N, Shrivastva A, Gupta N, Saxena P, Babu JP, Rao PVL, Morita K. Rapid and real-time detection of Chikungunya virus by reverse transcription loop-mediated isothermal amplification assay. J Clin Microbiol. 2007;45:351–7. https://doi.org/10.1128/JCM.01734-06.10.1128/JCM.01734-06 ↗
30. Wu S, Abdullah Al-Maskri AA, Li Q, Liu J, Cai S. A novel miRNA detection method using loop-mediated isothermal amplification. Int J Anal Chem. 2023;2023:6624884. https://doi.org/10.1155/2023/6624884.10.1155/2023/6624884 ↗
31. Tsai SM, Chan KW, Hsu WL, Chang TJ, Wong ML, Wang CY. Development of a loop-mediated isothermal amplification for rapid detection of orf virus. J Virol Methods. 2009;157:200–4. https://doi.org/10.1016/j.jviromet.2009.01.003.10.1016/j.jviromet.2009.01.003 ↗
32. Oscorbin IP, Belousova EA, Zakabunin AI, Boyarskikh UA, Filipenko ML. Comparison of fluorescent intercalating dyes for quantitative loop-mediated isothermal amplification (qLAMP). Biotechniques. 2016;61:20–5. https://doi.org/10.2144/000114432.10.2144/000114432 ↗
33. Frickmann H, Wiemer DF, Wassill L, Hinz R, Rojak S, Wille A, Loderstädt U, Schwarz NG, von Kalckreuth V, Im J, Jin Jeon H, Marks F, Owusu-Dabo E, Sarpong N, May J, Eibach D, Dekker D. Loop-mediated isothermal amplification-based detection of typhoid fever on an automated Genie II Mk2 system - a case-control-based approach. Acta Trop. 2019;190:293–5. https://doi.org/10.1016/j.actatropica.2018.12.004.10.1016/j.actatropica.2018.12.004 ↗
34. Uddin SM, Ibrahim F, Sayad AA, Thiha A, Pei KX, Mohktar MS, Hashim U, Cho J, Thong KL. A portable automatic endpoint detection system for amplicons of loop mediated isothermal amplification on microfluidic compact disk platform. Sensors (Basel). 2015;15:5376–89. https://doi.org/10.3390/s150305376.10.3390/s150305376 ↗
35. Liu Z, Zhang Q, Yang NN, Xu MG, Xu JF, Jing ML, Wu WX, Lu YD, Shi F, Chen CF. Rapid and sensitive detection of Salmonella in chickens using loop-mediated isothermal amplification combined with a lateral flow dipstick. J Microbiol Biotechnol. 2019;29:454–64. https://doi.org/10.4014/jmb.1712.12010.10.4014/jmb.1712.12010 ↗
36. Nwe MK, Jangpromma N, Taemaitree L. Evaluation of molecular inhibitors of loop-mediated isothermal amplification (LAMP). Sci Rep. 2024;14:5916. https://doi.org/10.1038/s41598-024-55241-z.10.1038/s41598-024-55241-z ↗
37. Tighe SW, Hayden AF, Kuentzel ML, Eckstrom KM, Foox J, Vellone DL, Finstad KH, Laaguiby PK, Hoffman JJ, Chittur SV. Molecular characterization of increased amplicon lengths in SARS-CoV-2 reverse transcription loop-mediated isothermal amplification assays. J Biomol Tech. 2021;32:199–205. https://doi.org/10.7171/jbt.21-3203-015.10.7171/jbt.21-3203-015 ↗
38. Wang S, Liu N, Zheng L, Cai G, Lin J. A lab-on-chip device for the sample-in-result-out detection of viable Salmonella using loop-mediated isothermal amplification and real-time turbidity monitoring. Lab Chip. 2020;20:2296–305. https://doi.org/10.1039/d0lc00290a.10.1039/d0lc00290a ↗
39. Priya GB, Agrawal RK, Prince Milton AA, Mishra M, Mendiratta SK, Luke A, Inbaraj S, Singh BR, Kumar D, Kumar GR, Rajkhowa S. Rapid and visual detection of Salmonella in meat using invasin A (invA) gene-based loop-mediated isothermal amplification assay. LWT. 2020;126: 109262. https://doi.org/10.1016/j.lwt.2020.109262.10.1016/j.lwt.2020.109262 ↗
40. Yang Q, Chen S, Ge B. Detecting Salmonella serovars in shell eggs by loop-mediated isothermal amplification. J Food Prot. 2013;76:1790–6. https://doi.org/10.4315/0362-028X.JFP-13-140.10.4315/0362-028X.JFP-13-140 ↗
41. Wang C, Xu Z, Hou X, Wang M, Zhou C, Liang J, Wei P. Rapid, sensitive, specific, and visual detection of Salmonella in retail meat with loop-mediated isothermal amplification, targeting the invA gene. J Food Prot. 2022;85:6–12. https://doi.org/10.4315/JFP-21-186.10.4315/JFP-21-186 ↗
42. Francois P, Tangomo M, Hibbs J, Bonetti EJ, Boehme CC, Notomi T, Perkins MD, Schrenzel J. Robustness of a loop-mediated isothermal amplification reaction for diagnostic applications. FEMS Immunol Med Microbiol. 2011;62:41–8. https://doi.org/10.1111/j.1574-695X.2011.00785.x.10.1111/j.1574-695X.2011.00785.x ↗
43. Ou H, Wang Y, Gao J, Bai J, Zhang Q, Shi L, Wang X, Wang C. Rapid detection of Salmonella based on loop-mediated isothermal amplification. Ann Palliat Med. 2021;10:6850–8. https://doi.org/10.21037/apm-21-1387.10.21037/apm-21-1387 ↗
44. Techathuvanan C, Draughon FA, D’Souza DH. Loop-mediated isothermal amplification (LAMP) for the rapid and sensitive detection of Salmonella Typhimurium from pork. J Food Sci. 2010;75:M165–72. https://doi.org/10.1111/j.1750-3841.2010.01554.x.10.1111/j.1750-3841.2010.01554.x ↗
45. Chu J, Shin J, Kang S, Shin S, Chung YJ. Rapid and sensitive detection of Salmonella species targeting the hilA gene using a loop-mediated isothermal amplification assay. Genom Inform. 2021;19: e30. https://doi.org/10.5808/gi.21048.10.5808/gi.21048 ↗
46. Zhao Y, Jiang X, Qu Y, Pan R, Pang X, Jiang Y, Man C. Salmonella detection in powdered dairy products using a novel molecular tool. J Dairy Sci. 2017;100:3480–96. https://doi.org/10.3168/jds.2016-12535.10.3168/jds.2016-12535 ↗
47. Hu L, Cao G, Brown EW, Allard MW, Ma LM, Zhang G. Whole genome sequencing and protein structure analyses of target genes for the detection of Salmonella. Sci Rep. 2021;11:20887. https://doi.org/10.1038/s41598-021-00224-7.10.1038/s41598-021-00224-7 ↗
48. Hara-Kudo Y, Yoshino M, Kojima T, Ikedo M. Loop-mediated isothermal amplification for the rapid detection of Salmonella. FEMS Microbiol Lett. 2005;253:155–61. https://doi.org/10.1016/j.femsle.2005.09.032.10.1016/j.femsle.2005.09.032 ↗
49. Zhao X, Wang L, Chu J, Li Y, Li Y, Xu Z, Li L, Shirtliff ME, He X, Liu Y, Wang J, Yang L. Development and application of a rapid and simple loop-mediated isothermal amplification method for food-borne Salmonella detection. Food Sci Biotechnol. 2010;19:1655–9. https://doi.org/10.1007/s10068-010-0234-4.10.1007/s10068-010-0234-4 ↗
50. Zhang G, Brown EW, González-Escalona N. Comparison of real-time PCR, reverse transcriptase real-time PCR, loop-mediated isothermal amplification, and the FDA conventional microbiological method for the detection of Salmonella spp. in produce. Appl Environ Microbiol. 2011;77:6495–501. https://doi.org/10.1128/AEM.00520-11.10.1128/AEM.00520-11 ↗
51. Chen Z, Zhang K, Yin H, Li Q, Wang L, Liu Z. Detection of Salmonella and several common Salmonella serotypes in food by loop-mediated isothermal amplification method. Food Sci Human Wellness. 2015;4:75–9. https://doi.org/10.1016/j.fshw.2015.05.001.10.1016/j.fshw.2015.05.001 ↗
52. Ahmad F, Seyrig G, Tourlousse DM, Stedtfeld RD, Tiedje JM, Hashsham SA. A CCD-based fluorescence imaging system for real-time loop-mediated isothermal amplification-based rapid and sensitive detection of waterborne pathogens on microchips. Biomed Microdevices. 2011;13:929–37. https://doi.org/10.1007/s10544-011-9562-2.10.1007/s10544-011-9562-2 ↗
53. Li X, Zhang S, Zhang H, Zhang L, Tao H, Yu J, Zheng W, Liu C, Lü D, Xiang R, Liu Y. A loop-mediated isothermal amplification method targets the phoP gene for the detection of Salmonella in food samples. Int J Food Microbiol. 2009;133:252–8. https://doi.org/10.1016/j.ijfoodmicro.2009.05.027.10.1016/j.ijfoodmicro.2009.05.027 ↗
54. Tourlousse DM, Ahmad F, Stedtfeld RD, Seyrig G, Tiedje JM, Hashsham SA. A polymer microfluidic chip for quantitative detection of multiple water- and foodborne pathogens using real-time fluorogenic loop-mediated isothermal amplification. Biomed Microdevices. 2012;14:769–78. https://doi.org/10.1007/s10544-012-9658-3.10.1007/s10544-012-9658-3 ↗
55. Zhang L, Pan Z, Geng S, Chen X, Liu Z, Zhao F, Jiao X. A loop-mediated isothermal amplification method targets the HisJ gene for the detection of foodborne Salmonella. Eur Food Res Technol. 2012;234:1055–62. https://doi.org/10.1007/s00217-012-1725-8.10.1007/s00217-012-1725-8 ↗
56. Zhang Y, Shan X, Shi L, Lu X, Tang S, Wang Y, Li Y, Alam MJ, Yan H. Development of a fimY-based loop-mediated isothermal amplification assay for detection of Salmonella in food. Food Res Int. 2012;45:1011–5. https://doi.org/10.1016/j.foodres.2011.02.015.10.1016/j.foodres.2011.02.015 ↗
57. Oh SJ, Park BH, Jung JH, Choi G, Lee DC, Kim DH, Seo TS. Centrifugal loop-mediated isothermal amplification microdevice for rapid, multiplex and colorimetric foodborne pathogen detection. Biosens Bioelectron. 2016;75:293–300. https://doi.org/10.1016/j.bios.2015.08.052.10.1016/j.bios.2015.08.052 ↗
58. Patterson AS, Heithoff DM, Ferguson BS, Soh HT, Mahan MJ, Plaxco KW. Microfluidic chip-based detection and intraspecies strain discrimination of Salmonella serovars derived from whole blood of septic mice. Appl Environ Microbiol. 2013;79:2302–11. https://doi.org/10.1128/AEM.03882-12.10.1128/AEM.03882-12 ↗
59. Zhuang L, Gong J, Li Q, Zhu C, Yu Y, Dou X, Liu X, Xu B, Wang C. Detection of Salmonella spp. by a loop-mediated isothermal amplification (LAMP) method targeting bcfD gene. Lett Appl Microbiol. 2014;59:658–64. https://doi.org/10.1111/lam.12328.10.1111/lam.12328 ↗
60. Liu N, Zou D, Dong D, Yang Z, Ao D, Liu W, Huang L. Development of a multiplex loop-mediated isothermal amplification method for the simultaneous detection of Salmonella spp. and Vibrio parahaemolyticus. Sci Rep. 2017;7:45601. https://doi.org/10.1038/srep45601.10.1038/srep45601 ↗
61. Srisawat M, Panbangred W. Efficient and specific detection of Salmonella in food samples using a stn-based loop-mediated isothermal amplification method. Biomed Res Int. 2015;2015:356401. https://doi.org/10.1155/2015/356401.10.1155/2015/356401 ↗
62. Li J, Zhai L, Bie X, Lu Z, Kong X, Yu Q, Lv F, Zhang C, Zhao H. A novel visual loop-mediated isothermal amplification assay targeting gene62181533 for the detection of Salmonella spp. in foods. Food Control. 2016;60:230–6. https://doi.org/10.1016/j.foodcont.2015.07.036.10.1016/j.foodcont.2015.07.036 ↗
63. Shang Y, Ye Q, Cai S, Wu Q, Pang R, Yang S, Xiang X, Wang C, Zha F, Ding Y, Zhang Y, Wang J, Sun X, Zhang J. Loop-mediated isothermal amplification (LAMP) for rapid detection of Salmonella in foods based on new molecular targets. LWT. 2021;142: 110999. https://doi.org/10.1016/j.lwt.2021.110999.10.1016/j.lwt.2021.110999 ↗
64. Kim MJ, Kim HJ, Kim HY. Direct triplex loop-mediated isothermal amplification assay for the point-of-care molecular detection of Salmonella genus, subspecies I, and serovar Typhimurium. Food Control. 2021;120: 107504. https://doi.org/10.1016/j.foodcont.2020.107504.10.1016/j.foodcont.2020.107504 ↗
65. Kreitlow A, Becker A, Schotte U, Malorny B, Plötz M, Abdulmawjood A. Establishment and validation of a loop-mediated isothermal amplification (LAMP) assay targeting the ttrRSBCA locus for rapid detection of Salmonella spp. in food. Food Control. 2021;126:107973. https://doi.org/10.1016/j.foodcont.2021.107973.10.1016/j.foodcont.2021.107973 ↗
66. Okamura M, Ohba Y, Kikuchi S, Takehara K, Ikedo M, Kojima T, Nakamura M. Rapid, sensitive, and specific detection of the O4 group of Salmonella enterica by loop-mediated isothermal amplification. Avian Dis. 2009;53:216–21. https://doi.org/10.1637/8450-081808-Reg.1.10.1637/8450-081808-Reg.1 ↗
67. Okamura M, Ohba Y, Kikuchi S, Suzuki A, Tachizaki H, Takehara K, Ikedo M, Kojima T, Nakamura M. Loop-mediated isothermal amplification for the rapid, sensitive, and specific detection of the O9 group of Salmonella in chickens. Vet Microbiol. 2008;132:197–204. https://doi.org/10.1016/j.vetmic.2008.04.029.10.1016/j.vetmic.2008.04.029 ↗
68. Rödel J, Edel B, Braun SD, Ehricht R, Simon S, Fruth A, Löffler B. Simple differentiation of Salmonella Typhi, Paratyphi and Choleraesuis from Salmonella species using the eazyplex TyphiTyper LAMP assay. J Med Microbiol. 2020;69:817–23. https://doi.org/10.1099/jmm.0.001201.10.1099/jmm.0.001201 ↗
69. Ravan H, Yazdanparast R. Development and evaluation of a loop-mediated isothermal amplification method in conjunction with an enzyme-linked immunosorbent assay for specific detection of Salmonella serogroup D. Anal Chim Acta. 2012;733:64–70. https://doi.org/10.1016/j.aca.2012.04.034.10.1016/j.aca.2012.04.034 ↗
70. Ravan H, Yazdanparast R. Development of a new loop-mediated isothermal amplification assay for prt (rfbS) gene to improve the identification of Salmonella serogroup D. World J Microbiol Biotechnol. 2012;28:2101–6. https://doi.org/10.1007/s11274-012-1014-5.10.1007/s11274-012-1014-5 ↗
71. Edel B, Glöckner S, Stoll S, Lindig N, Boden K, Wassill L, Simon S, Löffler B, Rödel J. Development of a rapid diagnostic test based on loop-mediated isothermal amplification to identify the most frequent non-typhoidal Salmonella serovars from culture. Eur J Clin Microbiol Infect Dis. 2023;42:461–70. https://doi.org/10.1007/s10096-023-04571-3.10.1007/s10096-023-04571-3 ↗
72. Hu L, Ma LM, Zheng S, He X, Hammack TS, Brown EW, Zhang G. Development of a novel loop-mediated isothermal amplification (LAMP) assay for the detection of Salmonella ser. Enteritidis from egg products. Food Control. 2018;88:190–7. https://doi.org/10.1016/j.foodcont.2018.01.006.10.1016/j.foodcont.2018.01.006 ↗
73. Garrido-Maestu A, Fuciños P, Azinheiro S, Carvalho J, Prado M. Systematic loop-mediated isothermal amplification assays for rapid detection and characterization of Salmonella spp., Enteritidis and Typhimurium in food samples. Food Control. 2017;80:297–306. https://doi.org/10.1016/j.foodcont.2017.05.011.10.1016/j.foodcont.2017.05.011 ↗
74. Yang J, Ma G, Yang R, Yang S, Fu L, Cheng A, Wang M, Zhang S, Shen K, Jia R, Deng S, Xu Z. Simple and rapid detection of Salmonella serovar Enteritidis under field conditions by loop-mediated isothermal amplification. J Appl Microbiol. 2010;109:1715–23. https://doi.org/10.1111/j.1365-2672.2010.04800.x.10.1111/j.1365-2672.2010.04800.x ↗
75. Gong J, Zhuang L, Zhu C, Shi S, Zhang D, Zhang L, Yu Y, Dou X, Xu B, Wang C. Loop-mediated isothermal amplification of the sefA gene for rapid detection of Salmonella Enteritidis and Salmonella Gallinarum in chickens. Foodborne Pathog Dis. 2016;13:177–81. https://doi.org/10.1089/fpd.2015.2082.10.1089/fpd.2015.2082 ↗
76. Fan F, Du P, Kan B, Yan M. The development and evaluation of a loop-mediated isothermal amplification method for the rapid detection of Salmonella enterica serovar Typhi. PLoS ONE. 2015;10: e0124507. https://doi.org/10.1371/journal.pone.0124507.10.1371/journal.pone.0124507 ↗
77. Kaur A, Kapil A, Elangovan R, Jha S, Kalyanasundaram D. Highly-sensitive detection of Salmonella typhi in clinical blood samples by magnetic nanoparticle-based enrichment and in-situ measurement of isothermal amplification of nucleic acids. PLoS ONE. 2018;13: e0194817. https://doi.org/10.1371/journal.pone.0194817.10.1371/journal.pone.0194817 ↗
78. Abdullah J, Saffie N, Sjasri FAR, Husin A, Abdul Rahman Z, Ismail A, Aziah I, Mohamed M. Rapid detection of Salmonella Typhi by loop-mediated isothermal amplification (LAMP) method. Braz J Microbiol. 2017;45:1385–91. https://doi.org/10.1590/s1517-83822014000400032.10.1590/s1517-83822014000400032 ↗
79. Fan F, Yan M, Du P, Chen C, Kan B. Rapid and sensitive Salmonella Typhi detection in blood and fecal samples using reverse transcription loop-mediated isothermal amplification. Foodborne Pathog Dis. 2015;12:778–86. https://doi.org/10.1089/fpd.2015.1950.10.1089/fpd.2015.1950 ↗
80. Kumar PP, Agarwal RK, Thomas P, Sailo B, Prasannavadhana A, Kumar A, Kataria JL, Singh DK. Rapid detection of Salmonella enterica subspecies enterica serovar Typhimurium by loop mediated isothermal amplification (LAMP) test from field chicken meat samples. Food Biotechnol. 2014;28(1):50–62. https://doi.org/10.1080/08905436.2013.870911.10.1080/08905436.2013.870911 ↗
81. Kim E, Yang SM, Kim HY. Rapid detection of Salmonella enterica subsp. enterica serovar Thompson by real-time fluorescence loop-mediated isothermal amplification (LAMP) and colorimetric LAMP combined without DNA extraction in the field. LWT. 2023;182:114850. https://doi.org/10.1016/j.lwt.2023.114850.10.1016/j.lwt.2023.114850 ↗
82. Han L, Wang K, Ma L, Delaquis P, Bach S, Feng J, Lu X. Viable but nonculturable Escherichia coli O157:H7 and Salmonella enterica in fresh produce: rapid determination by loop-mediated isothermal amplification coupled with a propidium monoazide treatment. Appl Environ Microbiol. 2020;86:e02566-19. https://doi.org/10.1128/AEM.02566-19.10.1128/AEM.02566-19 ↗
83. Halcon MHSC, Santos JAP, Lantican NB. Detection of Salmonella enterica subsp. enterica via quenching of unincorporated amplification signal reporters in loop-mediated isothermal amplification. Sci World J. 2022;2022:4567817. https://doi.org/10.1155/2022/4567817.10.1155/2022/4567817 ↗
84. Ravan H, Yazdanparast R. Loop region-specific oligonucleotide probes for loop-mediated isothermal amplification-enzyme-linked immunosorbent assay truly minimize the instrument needed for detection process. Anal Biochem. 2013;439:102–8. https://doi.org/10.1016/j.ab.2013.04.014.10.1016/j.ab.2013.04.014 ↗
85. Liu W, Zhang S, Chen C, Jin J, Liu H, Bian Z, Qi W, Xie Y, Zhang H. Development of a visual detection method for Salmonella based on loop-mediated isothermal amplification using pyrophosphatase. FEMS Microbiol Lett. 2023;370:fnad040. https://doi.org/10.1093/femsle/fnad040.10.1093/femsle/fnad040 ↗
86. Nocker A, Cheung CY, Camper AK. Comparison of propidium monoazide with ethidium monoazide for differentiation of live versus dead bacteria by selective removal of DNA from dead cells. J Microbiol Methods. 2006;67:310–20. https://doi.org/10.1016/j.mimet.2006.04.015.10.1016/j.mimet.2006.04.015 ↗
87. Fang J, Wu Y, Qu D, Ma B, Yu X, Zhang M, Han J. Propidium monoazide real-time loop-mediated isothermal amplification for specific visualization of viable Salmonella in food. Lett Appl Microbiol. 2018;67:79–88. https://doi.org/10.1111/lam.12992.10.1111/lam.12992 ↗
88. Youn SY, Jeong OM, Choi BK, Jung SC, Kang MS. Application of loop-mediated isothermal amplification with propidium monoazide treatment to detect live Salmonella in chicken carcasses. Poult Sci. 2017;96:458–64. https://doi.org/10.3382/ps/pew341.10.3382/ps/pew341 ↗
89. Chen S, Wang F, Beaulieu JC, Stein RE, Ge B. Rapid detection of viable Salmonellae in produce by coupling propidium monoazide with loop-mediated isothermal amplification. Appl Environ Microbiol. 2011;77:4008–16. https://doi.org/10.1128/AEM.00354-11.10.1128/AEM.00354-11 ↗
90. Trieu PT, Lee NY. Paper-based all-in-one origami microdevice for nucleic acid amplification testing for rapid colorimetric identification of live cells for point-of-care testing. Anal Chem. 2019;91:11013–22. https://doi.org/10.1021/acs.analchem.9b01263.10.1021/acs.analchem.9b01263 ↗
91. Kumar SS, Ghosh AR. Assessment of bacterial viability: a comprehensive review on recent advances and challenges. Microbiol (Reading). 2019;165:593–610. https://doi.org/10.1099/mic.0.000786.10.1099/mic.0.000786 ↗
92. Bleve G, Rizzotti L, Dellaglio F, Torriani S. Development of reverse transcription (RT)-PCR and real-time RT-PCR assays for rapid detection and quantification of viable yeasts and molds contaminating yogurts and pasteurized food products. Appl Environ Microbiol. 2003;69:4116–22. https://doi.org/10.1128/AEM.69.7.4116-4122.2003.10.1128/AEM.69.7.4116-4122.2003 ↗
93. Techathuvanan C, D’Souza DH. Reverse-transcriptase loop-mediated isothermal amplification as a rapid screening/monitoring tool for Salmonella enterica detection in liquid whole eggs. J Food Sci. 2012;77:M200–5. https://doi.org/10.1111/j.1750-3841.2011.02601.x.10.1111/j.1750-3841.2011.02601.x ↗
94. Techathuvanan C, Draughon FA, D’Souza DH. Comparison of reverse transcriptase PCR, reverse transcriptase loop-mediated isothermal amplification, and culture-based assays for Salmonella detection from pork processing environments. J Food Prot. 2011;74:294–301. https://doi.org/10.4315/0362-028X.JFP-10-306.10.4315/0362-028X.JFP-10-306 ↗
95. Lamas A, Santos SB, Prado M, Garrido-Maestu A. Phage amplification coupled with loop-mediated isothermal amplification (PA-LAMP) for same-day detection of viable Salmonella Enteritidis in raw poultry meat. Food Microbiol. 2023;115: 104341. https://doi.org/10.1016/j.fm.2023.104341.10.1016/j.fm.2023.104341 ↗
96. Du Z, Lin S, Li J, Tian J, Xu W, Huang K, Liu Q, Sun Y. Nano-gold-enhanced LAMP method for qualitative visual detection of Salmonella in milk. Mikrochim Acta. 2022;189:365. https://doi.org/10.1007/s00604-022-05459-3.10.1007/s00604-022-05459-3 ↗
97. Draz MS, Ma L, Lu X. Ultrasensitive DNA detection with hydrodynamic separation of plasmonic nanoparticles and isothermal amplification. J Biomed Nanotechnol. 2018;14:1025–38. https://doi.org/10.1166/jbn.2018.2507.10.1166/jbn.2018.2507 ↗
98. Trinh TND, Lee NY. A rapid and eco-friendly isothermal amplification microdevice for multiplex detection of foodborne pathogens. Lab Chip. 2018;18:2369–77. https://doi.org/10.1039/c8lc00424b.10.1039/c8lc00424b ↗
99. Trinh TND, Lee NY. A foldable isothermal amplification microdevice for fuchsin-based colorimetric detection of multiple foodborne pathogens. Lab Chip. 2019;19:1397–405. https://doi.org/10.1039/c8lc01389f.10.1039/c8lc01389f ↗
100. Trinh KTL, Trinh TND, Lee NY. Fully integrated and slidable paper-embedded plastic microdevice for point-of-care testing of multiple foodborne pathogens. Biosens Bioelectron. 2019;135:120–8. https://doi.org/10.1016/j.bios.2019.04.011.10.1016/j.bios.2019.04.011 ↗