Microrocket Based Viscometer
Source abstract
Abstract
Liquid viscosity is a vital metric in microelectromechanical systems (MEMS) and nanoelectromechanical systems (NEMS). The application of conventional viscosity measurements in micro/nano scale is complex and not economically viable. Self-propelled catalytic microrockets, capable of converting energy into movement and forces, have shown considerable promise for diverse practical applications in MEMS/NEMS. In this work, a novel micromotor-based viscometer is developed. The relation between the velocity of microrocket and the viscosity of solution is experimentally studied and theoretically modelled. A linear relationship between both variables is observed, with a decrease in the velocity of microrocket as the viscosity of solution increases. The microrocket based viscometer can be used to measure the viscosity within the range of 1.5-6.361 cP, 1.5-6.575 cP, and 1.5-7.486 cP in 5%, 7.5% and 10% H2O2 solutions, respectively. Compared with traditional viscometers, the newly developed microrocket-based viscometer represent a cost-effective, and ultracompact sized alternative that can be used for viscosity measurement in MEMS and NEMS.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Micro and Nano Robotics · Microfluidic and Bio-sensing Technologies · Molecular Communication and Nanonetworks
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (45)
Show source-provided references
1. 10.1021/nn302899710.1021/nn3028997 ↗
2. 10.1038/scientificamerican0509-7210.1038/scientificamerican0509-72 ↗
3. 10.1039/c0cs00078g10.1039/c0cs00078g ↗
4. 10.1146/annurev-bioeng-010510-10340910.1146/annurev-bioeng-010510-103409 ↗
5. 10.1038/ncomms611910.1038/ncomms6119 ↗
6. 10.1002/anie.20140609610.1002/anie.201406096 ↗
7. 10.1021/ja511012v10.1021/ja511012v ↗
8. 10.1021/ja411705d10.1021/ja411705d ↗
9. 10.1021/ja047697z10.1021/ja047697z ↗
10. 10.1002/anie.20130091310.1002/anie.201300913 ↗
11. 10.1038/ncomms155010.1038/ncomms1550 ↗
12. 10.1021/ja504150e10.1021/ja504150e ↗
13. 10.1002/adfm.20150105010.1002/adfm.201501050 ↗
14. 10.1021/nn504295z10.1021/nn504295z ↗
15. 10.1021/nn506200x10.1021/nn506200x ↗
16. 10.1021/nn507097k10.1021/nn507097k ↗
17. 10.1021/nn501407r10.1021/nn501407r ↗
18. 10.1002/anie.20130962910.1002/anie.201309629 ↗
19. 10.1002/adfm.20090237610.1002/adfm.200902376 ↗
20. 10.1038/ncomms602610.1038/ncomms6026 ↗
21. 10.1002/chem.20110145010.1002/chem.201101450 ↗
22. 10.1021/nn405075d10.1021/nn405075d ↗
23. 10.1002/smll.20140221510.1002/smll.201402215 ↗
24. 10.1039/c3nr01458d10.1039/c3nr01458d ↗
25. 10.1039/C5CC00546A10.1039/C5CC00546A ↗
26. 10.1021/nn505029k10.1021/nn505029k ↗
27. 10.1140/epje/i2010-10593-310.1140/epje/i2010-10593-3 ↗
28. 10.1021/la061595010.1021/la0615950 ↗
29. 10.1021/ja203773g10.1021/ja203773g ↗
30. 10.1002/adma.20130120810.1002/adma.201301208 ↗
31. 10.1021/jp311977d10.1021/jp311977d ↗
32. 10.1103/PhysRevLett.109.12830510.1103/PhysRevLett.109.128305 ↗
33. 10.1063/1.491511410.1063/1.4915114 ↗
34. 10.1039/C4SM01070A10.1039/C4SM01070A ↗
35. 10.1039/c1nr10840a10.1039/c1nr10840a ↗
36. 10.1016/j.expthermflusci.2006.03.01410.1016/j.expthermflusci.2006.03.014 ↗
37. 10.1146/annurev-chembioeng-061010-11421510.1146/annurev-chembioeng-061010-114215 ↗
38. 10.1039/c1lc20376b10.1039/c1lc20376b ↗
39. 10.1021/ac049468110.1021/ac0494681 ↗
40. 10.1021/ac051804610.1021/ac0518046 ↗
41. 10.1039/c2nr30138e10.1039/c2nr30138e ↗
42. 10.1205/0263876015242429910.1205/02638760152424299 ↗
43. 10.1021/ie049131p10.1021/ie049131p ↗
44. 10.1016/j.ces.2006.12.06110.1016/j.ces.2006.12.061 ↗
45. 10.1016/S0255-2701(03)00017-510.1016/S0255-2701(03)00017-5 ↗