journal article·2021-02

Experimental evaluation of column base connections composed by different grout types subject to shear

Laura Maria Paes de Abreu, Hermes Carvalho, Ricardo Hallal Fakury, Francisco Carlos Rodrigues, Rodrigo Barreto Caldas

Publisher page

Abstract

Abstract The column base connection is responsible for transferring the superstructure actions to the foundation and consists, typically, of a base plate and threaded steel bars or anchor rods. A grout layer is used for filling the clearance between the base plate and the top of concrete block, usually composed of a fluid-based hydraulic cementitious material with specific mechanical properties as high strength, negligible shrinkage, brittleness and delayed curing. Epoxy-based materials may be used as a more efficient material on applications with impact and dynamic loads or when a quick cure is required but as it is a recently developed material, its adoption occurs empirically. There are few studies about the use of this material in base column connections and mainly about its contribution to shear resistance due to the higher strength of this material. The international codes of steel and composite structures do not provide design guidance for the application of this material in base connections. Because of this lack of information, this work presents an experimental campaign about the behaviour of regular column bases, with a pre-installed steel anchor rod and grout layer composed of cement and epoxy materials, subject to monotonic shear forces.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Geotechnical Engineering and Analysis · Geotechnical Engineering and Underground Structures · Structural Load-Bearing Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (26)

Show source-provided references
1. I. Gomez, A. Kanvinde, C. Smith, G. Deierlein, Shear transfer in exposed column base plates, Report presented by the American Institute of Steel Construction, 2009.
2. American Institute of Steel Construction (AISC), ANSI/AISC 360-10, “Specification for Structural Steel Buildings”, American Institute of Steel Construction, Chicago, IL, 2010.
3. ACI Committee 351 (2012). Grouting between foundations and bases for support of equipment and machinery (ACI 351.1R-12), American Concrete Institute, Farmington Hills, MI., 2012.
4. Effect of grout properties on shear strength of column base connections: FEA and analytical approach10.1016/j.engstruct.2017.08.065 ↗
5. Effects of fillers on the properties of cement grouts10.1016/j.conbuildmat.2020.118346 ↗
6. 3D analytical investigation on the overall pullout behavior of grouted anchorages in presence of shear failure of grout10.1016/j.engfailanal.2019.104249 ↗
7. Investigations of rock anchor corrosion and its influence factors by exhumations in four typical field sites10.1016/j.engfailanal.2019.03.022 ↗
8. Experimental investigation on the failure modes of grouted sleeve connections under thermal and mechanical loads10.1016/j.engfailanal.2019.104246 ↗
9. Experimental data on the properties of polymer-modified cement grouts using epoxy and acrylic resin emulsions10.1016/j.dib.2016.09.016 ↗
10. Fundamental properties of epoxy resin-modified cement grouts10.1016/j.conbuildmat.2016.08.050 ↗
11. Characterisation of mechanical and thermal properties of epoxy grouts for composite repair of steel pipelines10.1016/j.matdes.2013.05.068 ↗
12. Evaluation of grout materials for CFRP ground anchors with strap ends10.1016/j.conbuildmat.2017.04.002 ↗
13. EN 1994-1-1:2004. Eurocode 4: Design of composite steel and concrete structures - Part 1-1: General rules and rules for buildings, CEN, Brussels, 2004.
14. Fisher · 2006
15. A.M. Gresnigt, A. Romeijn, F. Wald, C.M. Steenhuis, Column bases in shear and normal force, HERON, Volume 53, Issue 1/2, Special issue: Steel Column Bases, 2008.
16. Onderzoek naar de bevestiging van stalen voetplaten aan funderingen van beton. (Research into the connection of steel base plates to concrete foundations), TU-Delft Stevin Laboratory report 25.6.89.05/c6, Delft
17. EN 1993-1-8:2006. Eurocode 3: Design of Steel Structures, Part 1.8: Design of joints. Brussels, Belgium: European Committee for Standardization (CEN), 2006.
18. Simulation and design of exposed anchor rods in shear10.1504/IJTAMM.2011.043534 ↗
19. Fischer · 2004
20. J.E. Grauvilardell, D. Lee, J.F. Ajar, R.J. Dexter, Synthesis of Design, Testing and Analysis Research on Steel Column Base Plate Connections in High Seismic Zones, Structural engineering report no. ST-04-02. Minneapolis (MN): Department of Civil Engineering, University of Minnesota, 2005.
21. ASTM C827 / C827M-16, Standard Test Method for Change in Height at Early Ages of Cylindrical Specimens of Cementitious Mixtures, ASTM International, West Conshohocken, PA, 2016.
22. ASTM C1090 / C1090M-15, Standard Test Method for Measuring Changes in Height of Cylindrical Specimens of Hydraulic-Cement Grout, ASTM International, West Conshohocken, PA, 2015.
23. MC-Bauchemie (2017). Manual técnico – Linha de Produtos. Available in https://www.mc-bauchemie.com.br/produtos/reforco-estrutural/#/challenges-applications on 22/03/2020.
24. Fakury · 2016
25. Behaviour of precast reinforced concrete columns subjected to monotonic short-term loading10.3221/IGF-ESIS.50.20 ↗