A new torquemeter to measure the influence of heat-treatment on torsional resistance of NiTi endodontic instruments

G. La Rosa, F. Lo Savio, E. Pedullà, E. Rapisarda

Publisher page

Abstract

Abstract NiTi endodontic rotary instruments have increased flexibility and strength compared with stainless steel instruments, but they seem to be vulnerable to fracture in clinical situations. Heat treatment (thermal processing) is one of the most fundamental approaches toward adjusting the transition temperatures of NiTi alloys and affecting the fatigue and torsional resistance of NiTi endodontic files. In recent years, novel thermo-mechanical processing and manufacturing technologies such as controlled memory wire (CM-wire), M-Wire and electrical discharge machining (EDM) have been developed to optimize the microstructure of NiTi alloys and their mechanical properties. Aim of this work was to investigate the torsional resistance (maximum torque load, and angular rotation) of NiTi instruments made by different thermo-mechanical and manufacturing processes. For this purpose, a torque device able to perform static and dynamic tests of Ni-Ti instruments for root canal treatment was designed and realized, by performing this device through the design and optimization of the single components and on the system globally.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Endodontics and Root Canal Treatments · Occupational health in dentistry · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (54)

Show source-provided references
1. An overview of nickel–titanium alloys used in dentistry10.1046/j.1365-2591.2000.00339.x ↗
2. Fatigue and mechanical properties of nickel-titanium endodontic instruments10.1097/00004770-200210000-00009 ↗
3. Serene · 1995
4. Torsional and stiffness properties of nickel–titanium K files10.1111/j.1365-2591.1995.tb00307.x ↗
5. Nickel-titanium rotary systems: review of existing instruments and geometries
6. Metallurgical characterization of a new nickel-titanium wire for rotary endodontic instruments10.1016/j.joen.2009.08.004 ↗
7. An initial investigation of the bending and torsional properties of nitinol root canal files10.1016/S0099-2399(88)80196-1 ↗
8. Torque during canal instrumentation using rotary nickel-titanium files10.1097/00004770-200003000-00007 ↗
9. Cyclic fatigue of ProFile rotary instruments after clinical use10.1046/j.1365-2591.1999.00296.x ↗
10. Cyclic fatigue of nickel-titanium rotary instruments in a double (S-shaped) simulated curvature10.1016/j.joen.2012.03.025 ↗
11. Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use10.1097/01.DON.0000129963.42882.C9 ↗
12. ProTaper rotary root canal preparation: assessment of torque and force in relation to canal anatomy10.1046/j.1365-2591.2003.00628.x ↗
13. Torsion and bending properties of shape memory and superelastic nickel-titanium rotary instruments10.1016/j.joen.2012.08.010 ↗
14. Instrument fracture: mechanisms, removal of fragments, and clinical outcomes10.1111/j.1601-1546.2009.00239.x ↗
15. Torsional strength and toughness of nickel-titanium rotary files10.1016/j.joen.2010.11.028 ↗
16. Cyclic fatigue resistance of two reciprocating nickel-titanium instruments after immersion in sodium hypochlorite10.1111/j.1365-2591.2012.02100.x ↗
17. Rotary NiTi instrument fracture and its consequences10.1016/j.joen.2006.06.008 ↗
18. Influence of cyclic torsional preloading on cyclic fatigue resistance of nickel – titanium instruments10.1111/iej.12400 ↗
19. Pedullà · 2015
20. Effect of cyclic torsional preloading on cyclic fatigue resistance of ProTaper Next and Mtwo nickel-titanium instruments10.1016/j.gien.2015.05.002 ↗
21. A retrospective clinical study of incidence of root canal instrument separation in an endodontics graduate program: a PennEndo database study10.1016/j.joen.2006.03.001 ↗
22. SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use10.1097/01.DON.0000132301.87637.4A ↗
23. An in vitro cyclic fatigue analysis of different endodontic nickel-titanium rotary instruments10.1016/j.joen.2011.12.034 ↗
24. Cyclic fatigue of NiTi rotary instruments in a simulated apical abrupt curvature10.1111/j.1365-2591.2009.01668.x ↗
25. Torsion and bending properties of OneShape and WaveOne instruments10.1016/j.joen.2014.11.010 ↗
26. Current challenges and concepts in the preparation of root canal systems: a review10.1097/01.DON.0000129039.59003.9D ↗
27. Comparative study of different novel nickel-titanium rotary systems for root canal preparation in severely curved root canals10.1016/j.joen.2013.10.010 ↗
28. Effects of raw material and rotational speed on the cyclic fatigue of ProFile Vortex rotary instruments10.1016/j.joen.2010.02.015 ↗
29. Current challenges and concepts of the thermomechanical treatment of nickel-titanium instruments10.1016/j.joen.2012.11.005 ↗
30. Cyclic fatigue analysis of a new generation of nickel titanium rotary instruments10.1016/j.joen.2008.12.010 ↗
31. Topçuoğlu · 2016
32. Orthodontic wires
33. Torsional and cyclic fatigue resistance of a new nickel-titanium instrument manufactured by electrical discharge machining10.1016/j.joen.2015.10.004 ↗
34. Analysis of electro discharge machined surfaces of EN-31 tool steel
35. F360 and F6 Skytaper: SEM evaluation of cleaning efficiency
36. Cyclic fatigue of Reciproc and WaveOne reciprocating instruments10.1111/j.1365-2591.2012.02015.x ↗
37. An in vitro comparison of torsional stress properties of three different rotary nickel-titanium files with a similar cross-sectional design10.1016/j.joen.2012.04.022 ↗
38. Canal preparation: single-file shaping technique
39. Clinical guidelines for the use of ProTaper Next instruments (Part I)
40. Comparison between a novel nickel titanium alloy and 508 nitinol on the cyclic fatigue life of ProFile 25/.04 rotary instruments10.1016/j.joen.2008.07.029 ↗
41. Bonfanti · 2005 · 74
42. La Rosa · 2016
43. Energy consumption of ProTaper Next X1 after glide path with PathFiles and ProGlider10.1016/j.joen.2014.08.011 ↗
44. Mock-up in hip arthroplasty pre-operative planning
45. Influence of clinical usage of GT and GTX files on cyclic fatigue resistance10.1111/iej.12141 ↗
46. Influence of cyclic torsional loading on the fatigue resistance of K3 instruments10.1111/j.1365-2591.2008.01449.x ↗
47. Cyclic fatigue and torsional resistance of two new nickel-titanium instruments used in reciprocation motion: Reciproc versus WaveOne10.1016/j.joen.2011.11.014 ↗
48. ISO 3630-1:2008(E).
49. Elastic limits in torsion of reciprocating nickel-titanium instruments10.1016/j.joen.2014.12.027 ↗
50. Bending properties of rotary nickel-titanium instruments10.1016/S1079-2104(03)00358-5 ↗
51. Dimensional characterization and mechanical behaviour of K3 rotary instruments10.1111/j.1365-2591.2007.01368.x ↗
52. Effect of fatigue on torsional failure of nickel-titanium controlled memory instruments10.1016/j.joen.2013.12.035 ↗
53. Lo Savio · 2016
54. Recent advances in dental optics Part II: experimental tests for a new intraoral scanner10.1016/j.optlaseng.2013.07.024 ↗