journal article·2018-08

Structural integrity assessment of the welded joints of the constitution of 1812 bridge (Cádiz, Spain)

M.A. Díaz García, S. Cicero, O.R. Ramos Gutiérrez

Publisher page

Abstract

As required by the current Spanish regulations, an inspection and maintenance plan has been completed for the Constitution of 1812 Bridge over the Bay of Cádiz (Spain), which defines the work to be performed on the different elements of the bridge during its service life. The part of the plan related to the inspection of the steel structure has a section dedicated to the inspection of the defects that may be present in the welded joints of the steel deck, providing critical defect sizes above which the safety of the structure would be compromised. With this purpose, in the most stressed points of the deck, the structural details that are most susceptible to fatigue and fracture phenomena have been identified. Moreover, fatigue tests of these details have been performed to complete a structural integrity assessment that also comprises the determination of the material fracture toughness and the definition of the corresponding critical crack sizes. The tests were carried out on specimens obtained with the same steel grades as those used in the bridge and with the same welding procedures as those practiced in the structure. The results show that the fatigue test results are above the SN curves provided by the Eurocode 3, and also that numerous critical crack sizes would not be detected by the usual inspection techniques used in bridges (visual inspection), so that further research into how to manage this issue is recommended.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Infrastructure Maintenance and Monitoring

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (18)

Show source-provided references
1. 2008
2. 2011
3. 2011
4. Introducción al Puente de la Constitución de 1812 sobre la bahía de Cádiz
5. BS 7910 2013, Guide to methods for assessing the acceptability of flaws in metallic structures, British Standards Institution, London, 2013.
6. FITNET FFS Procedure, Final draft MK7. Prepared by European Fitness-for-Service Network-FITNET, 2006.
7. API RP 579-1/ASME FFS-1 · 2016
8. On the fatigue and fracture of site splice welds at the river Mardle viaduct10.1016/S1350-6307(03)00022-0 ↗
9. Structural integrity assessment of the cast steel upper anchorage elements used in a cable stayed bridge10.1016/j.engstruct.2014.10.018 ↗
10. UNE-EN ISO 4063 · 2011
11. EN 1993-1-9. Eurocode 3: Design of steel structures - Part 1–9: Fatigue, European Committee for Standardization (CEN), Brussels, 2005.
12. UNE-EN 10027-1:2017 · 2017
13. EN ISO 6892-1:2016 · 2016
14. ASTM E466-15 · 2015
15. BS 7608:2013 · 2013
16. ASTM E1820-17 · 2017
17. XIII-1965-03/XV-1127-03 · 2009
18. ASTM E1921-17a · 2017