journal article·2024-10Open access

Microstructural and fatigue characterization of 316L stainless steel subjected to flow drilling and tapping: comparison with machined threads

Mohamed Akram Mechter, Mina Gadour, Léa Romain, Oguzhan Tuysuz, Myriam Brochu

Abstract

Despite extensive research on the plastic deformation of materials to enhance their fatigue resistance, the influence of the flow tapping process on the fatigue resistance of drilled and tapped bars remains poorly understood. Herein, the fatigue performance of flow-drilled (friction-drilled) and flow-tapped 316L stainless steel bars was experimentally analyzed and compared with that of conventional material-shearing-based drilling and tapping operations. The effect of flow processes on the material properties was evaluated via microhardness tests and microstructural analyses. The results indicated that the hardness near the holes produced via flow forming was 62 % higher than that of the base metal. Moreover, grain refinement and plastic deformation were observed beneath the thread surfaces. Metallographic observations revealed the occurrence of craters and folds at the crest of the flow-formed threads. Following the ASTM F382-17 standard, four-point bending fatigue tests were performed at three stress amplitudes with a stress ratio of 0.1. No noteworthy differences were observed when the maximum bending moments applied were at 75 % and 60 % of the bending moment at yield. However, when the maximum bending moment applied was limited to 50 % of the bending moment at yield, the average fatigue life of the specimens with machined threads was longer than that of their flow-formed counterparts. Fractographic observations were used to identify the crack initiation regions and elucidate the underlying fracture mechanisms. For both types of specimens, failure originated at the crest of the first thread, beneath the surface of the maximum tensile stress. The flow-processed specimens exhibited secondary cracks at the root of the threads, where grain refinement also occurred. This study provides robust empirical evidence that using flow-forming processes to thread 316L stainless steel does not systematically improve the fatigue resistance of the material surrounding the holes. Furthermore, by optimizing the flow process and eliminating discontinuities, the threading process proposed herein could help improve the fatigue resistance of orthopedic implants.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Fatigue and fracture mechanics · Erosion and Abrasive Machining · Metal Alloys Wear and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (17)

Show source-provided references
1. Fatigue performance of prosthetic screws used in dental implant restorations: Rolled versus cut threads
2. G. Fromentin, Mechanical and technological study of the cold form tapping process applied to hardened steel. https://pastel.hal.science/pastel-00000941, 2004. Accessed the 03 / 05 / 2024.
3. Microstructural alterations associated with friction drilling of steel, aluminum, and titanium10.1361/105994905X64558 ↗
4. Friction drilling of cast metals10.1016/j.ijmachtools.2005.09.003 ↗
5. Machining characteristic study of friction drilling on AISI 304 stainless steel10.1016/j.jmatprotec.2007.12.064 ↗
6. Grzesik · 2010 · 143
7. Effective use of technology flowdrill in production engineering
8. B. Gervais, A. Vadean, M. Raison, M. Brochu, Failure analysis of a 316L stainless steel femoral orthopedic implant, Case Stud. Eng. Fail Anal. 5–6 (206) 30–38. 10.1016/j.csefa.2015.12.001.10.1016/j.csefa.2015.12.001 ↗
9. Experimental investigation on fatigue evaluation of orthopaedic locking compression plate
10. Fatigue failure of an orthopedic implant – A locking compression plate10.1016/j.engfailanal.2007.04.001 ↗
11. Effects of conventional shot peening, severe shot peening, re-shot peening and precised grinding operations on fatigue performance of AISI 1050 railway axle steel10.1016/j.ijfatigue.2021.106613 ↗
12. Improvement of traction-traction fatigue properties of A100 steel plate-hole-structure by double shot peening10.1016/j.ijfatigue.2022.106925 ↗
13. Damage accumulation during initiation and short crack growth regimes10.1111/j.1460-2695.1981.tb01124.x ↗
14. ASTM E3-11 (2017), Standard Guide for Preparation of Metallographic Specimens https://www.astm.org/e0003-11r17.html.
15. ASTM E384-22 (2022), Standard test method for microindentation hardness of materials https://www.astm.org/e0384-22.html.
16. ASTM F382-17 (2017) Standard Specification and Test Method for Metallic Bone Plates https://www.astm.org/f0382-17.html.
17. Analysing the fatigue behaviour and residual stress relaxation of gradient nano-structured 316l steel subjected to the shot peening via deep learning approach10.1007/s12540-021-00995-8 ↗