Abstract The clamping force perpendicular to the fiber has a significant and complex effect on the fatigue behavior of the composite mechanical joint. In this paper, the pultrusion glass fiber reinforced polymer (GFRP) plate was selected, and the fatigue test (R = 0.1) was conducted to study the effect of clamping stress on the fatigue failure mode of the pre-tightening single tooth connector (PTSTC).The fatigue-test results show that reducing the maximum cyclic stress could increase the life under the same pre-tightening stress. Numerical analysis shown that under the same maximum cyclic stress, the shear stress concentration along the tooth-root plane decreased with the increase of pre-tightening stress. Therefore, the fatigue life corresponding to the interlaminar shear failure also increased. However, above a certain pre-tightening stress level, the life improvement discontinued because the failure mode changed from interlaminar shear failure on the tooth-root plane to fiber failure on the tooth groove. This phenomenon was verified using the Puck's fiber failure criterion. In addition, the numerical analysis results show that the tensile and transverse shear stress concentrations on the cross section in the tooth groove were more severe as the pre-tightening stress increased. Therefore, the fatigue life corresponding to the fiber failure also decreased. In summary, choosing an appropriate pre-tightening stress is critical to the fatigue design of GFRP PTSTCs.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Mechanical Behavior of Composites · Mechanical stress and fatigue analysis · Tribology and Wear Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (30)

Show source-provided references
1. Failure analysis of FRP laminates by means of physically based phenomenological models10.1016/S0266-3538(01)00208-1 ↗
2. The effect of hydrostatic pressure on the mechanical properties of glass fibre/epoxy unidirectional composites10.1016/S1359-835X(04)00152-6 ↗
3. Predicting the effect of through-thickness compressive stress on delamination using interface elements10.1016/j.compositesa.2007.11.005 ↗
4. Measurement and modelling of interlaminar shear strength enhancement under moderate through-thickness compression10.1016/j.compositesa.2013.02.004 ↗
5. The effect of through-thickness compressive stress on mode II interlaminar fracture toughness10.1016/j.compstruct.2017.09.014 ↗
6. The effect of through-thickness compressive stress on mode II interlaminar crack propagation: a computational micromechanics approach10.1016/j.compstruct.2017.09.020 ↗
7. Experimental study on clamping effects on the tensile strength of composite plates with a bolt-filled hole10.1016/S1359-835X(99)00002-0 ↗
8. Experimental analysis of failures in filled hole compression tests of carbon/epoxy laminate10.1016/j.compstruct.2009.10.008 ↗
9. An experimental investigation of the bolt clamping force and friction effect on the fatigue behavior of aluminum alloy 2024-T3 double shear lap joint10.1016/j.matdes.2011.04.022 ↗
10. The effect of high pressure on the failure of unidirectional carbon fibre/epoxy composites
11. The effect of hydrostatic pressure on the tensile properties of pultruded CFRP10.1007/BF01112298 ↗
12. Parry · 1986 · vol. 21 · 4451
13. Zinoviev · 2001 · 61 · 1151
14. A numerical approach for predicting the failure locus of fiber reinforced composites under combined transverse compression and axial tension10.1016/j.commatsci.2011.07.039 ↗
15. Effect of high through-thickness compressive stress on fibre direction tensile strength of carbon/epoxy composite laminates10.1016/j.compscitech.2013.10.010 ↗
16. Sigley · 1991 · 41 · 395
17. Literature review-effects of hydrostatic pressure on the mechanical behavior of composite materials10.1177/089270579500800403 ↗
18. Mechanical properties of unidirectional organic-fiber-reinforced plastics under hydrostatic pressure10.1016/S0266-3538(97)00079-1 ↗
19. Investigation the effect of tightening torque on the fatigue strength of double lap simple bolted and hybrid (bolted–bonded) joints using volumetric method10.1016/j.matdes.2014.06.021 ↗
20. Experimental and numerical investigation of the effect of clamping force on the fatigue behaviour of bolted plates10.1016/j.engfailanal.2007.04.009 ↗
21. Fatigue behaviour of aluminium alloy 7075 bolted joints treated with oily film corrosion compounds10.1016/S0261-3069(01)00060-7 ↗
22. Ultrasonic detection of fretting fatigue damage at bolt joints of aluminum alloy plates10.1016/j.ijfatigue.2009.03.017 ↗
23. Zhao · 2010
24. Current research and development of the application of the pre-tightened tooth connection
25. Failure modes and failure mechanisms of single tooth bound to composite pre-tightened tooth connection10.1177/0731684417741205 ↗
26. Deng · 2013
27. Zhang · 2015
28. Experimental and numerical study of the torsional response of a modular hybrid FRP-aluminum triangular deck-truss beam10.1016/j.engstruct.2016.12.007 ↗
29. Klebanov · 2007
30. Environmental effects on fatigue behavior of adhesively-bonded pultruded structural joints10.1016/j.compscitech.2009.01.024 ↗