journal article·2000-10

Metallurgical failure analysis of a BWR recirculation pump shaft

A.M Lancha, J Lapeña, M Serrano, I Gorrochategui

Engineering Failure Analysis· Volume 7· Issue 5
Publisher page

Abstract

Abstract This paper presents the metallurgical analysis of a Recirculation Pump from a Nuclear Power Plant. The damaged component was the austenitic stainless steel shaft. As a result of a preliminary visual examination, some axial cracks were found in the threaded area of the shaft in the thermal barrier area. The analyses performed include liquid penetrant testing, metallography and deposits analysis. Based on the obtained results, it was concluded that the origin of the axial cracks was thermal fatigue caused by mixing of cold seal injection water and hot reactor coolant in the thermal barrier area.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Mechanical Failure Analysis and Simulation · High Temperature Alloys and Creep · Nuclear Materials and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (8)

Show source-provided references
1. Shah VN, Macdonald PE. Residual life assessment of major LWR components-overview, Vol 1, NUREG/CR-4371, November 198910.1520/STP10393S ↗
2. Modal method for crack identification applied to reactor recirculation pump
3. Failure analysis and prevention. Metals handbook. 9th ed. American Society for Metals, vol. 11, 1986
4. Stress intensity factors for shafts with multiple axial cracks subject to thermal stress
5. Hayner GO. Examination of a failed reactor coolant pump rotating assembly from Crystal River Unit 3. In: Proceedings of the International Symposium on Contribution of Materials Investigation to the Resolution of Problems Encountered in PWR Plants. FONTEVRAUD III, 1990
6. Effect of surface condition and processing on fatigue performance
7. Fundamentals of modern fatigue analysis for design
8. Aging assessment of PWR surge and spray lines and LWR coolant pumps10.1016/0029-5493(90)90034-U ↗