Abstract A furnace outlet pipe made of INCOLOY® alloy 800H to handle gaseous hydrocarbon in a benzene plant developed cracks in the weld heat-affected zone during operation at 595 °C. Microstructural characterization revealed that the cracks were of the ductile intergranular mode, which could be related to localized plastic deformation alongside the grain boundaries. The microstructure of the heat-affected zone was distinguished from the base metal by a coarser grain structure and intergranular oxidation in addition to higher hardness indicating the presence of residual stresses from the welding process. Intergranular oxidation was found to result in a mixture of Cr and Fe oxides enveloping a Ni-rich solid-solution adjacent to the grain boundary. Therefore, the observed ductile intergranular cracking could be related to localized plastic deformation in the relatively “soft” zone of Ni-rich solid-solution. Most evidence indicated that the failure occurred because of improper welding atmosphere leading to internal oxidation under relatively low oxygen potential, which is oxidizing to Cr and to a lesser extent Fe, and reducing to Ni.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Hydrogen embrittlement and corrosion behaviors in metals · Corrosion Behavior and Inhibition · High-Temperature Coating Behaviors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (6)

Show source-provided references
1. Tawancy · 1994
2. INCOLOY® Alloy 800H and 800HT. Publication No. SMC-047, Special Metals Corporation, Huntington, West Virginia; 2004.
3. ASM handbook, Fractography, vol. 12, Materials Park, (Ohio): ASM International; 1987. p. 112.
4. Rothman MF, Storey IJ. Reliability and longevity of furnace components as influenced by alloy construction. HAYNES International Publication No. H-3124A, Kokomo, (Indiana); 2005.
5. Petite · 1976 · 375
6. Krupp · Mater Res · 2004 · 7 · 3510.1590/S1516-14392004000100006 ↗