Abstract

Abstract Intramedullary nails increasingly applied in stabilization of long bone fractures due to their advantage regarding to conventional approach. Moreover, in cases of non union or mal union of fragments of the bone, the nail can be subjected to an expressive portion of the external loads at full weigh-bearing instances, which can promotes short term fatigue fracture of the nail. This paper shows a case of two successive failure of the nail in an individual, who experienced severe plastic strain in a first slotted, unlocked nail and short term fatigue fracture of the second non slotted, stiffer locked nail. The failure of the first one was due to low stiffness whereas the second was due to non union or mal union of the femur after three months. The risk of nail failure may be minimized by using nails that have a larger diameter or stiffness and by avoiding early weight-bearing as well as by adequate post-operatory follow-up during healing period.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone fractures and treatments · Hip and Femur Fractures · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (14)

Show source-provided references
1. Failure of the spiral blade and intramedullary nail in the treatment of ipsilateral femoral neck and shaft fractures10.1016/j.injury.2006.07.053 ↗
2. Die Marknagelung von Knochenbrüchen
3. The Küntscher method of intramedullary fixation10.2106/00004623-195840010-00002 ↗
4. Loads acting in an intramedullary nail during fracture healing in the human fêmur10.1016/S0021-9290(01)00037-9 ↗
5. Fatigue fracture of the interlocking nail in the treatment of fractures of the distal part of the femoral shaft10.2106/00004623-198769090-00012 ↗
6. The fixion proximal femur nailing system: biomechanical properties of the nail and a cadaveric study10.1016/j.jbiomech.2004.03.014 ↗
7. Unreamed intramedullary tibial nailing – fatigue of locking bolts10.1016/0020-1383(95)00150-6 ↗
8. Mechanical failure of intramedullary nails after fracture union
9. Intramedullary locking nails for femoral shaft fractures in elderly patients10.1302/0301-620X.72B1.2298787 ↗
10. Mechanical failure in intramedullary interlocking nails10.1177/230949900601400206 ↗
11. The Holland nail®: a universal implant for fractures of the proximal femur and the femoral shaft, injury10.1016/S0020-1383(03)00165-7 ↗
12. An investigation into the load transfer in interlocking intramedullary nails during simulated healing of a femoral fracture
13. Intramedullary nailing in segmental tibial fractures10.2106/00004623-198163080-00014 ↗
14. A biomechanical comparison of unlocked or locked reamed intramedullary nails in the treatment of mid-third simple transverse femoral shaft fractures