journal article·2006-06

Failure of a screw compressor shaft

A. Shahrivar, A.R. Abdolmaleki

Engineering Failure Analysis· Volume 13· Issue 4
Publisher page

Abstract

Abstract Screw compressors used to produce compressed air in refineries have two rotors. One of the main causes of failure of these compressors is rotor fracture. In this research, the fracture causes of the female rotor of a screw compressor after only 603 working hours was studied. Experiments showed that the main cause of the failure was fatigue due to a defect in the cooling system of the compressor that caused thermal expansion, touching of rotors and finally fracture after only 25–43 min.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Mechanical Failure Analysis and Simulation · Engineering Diagnostics and Reliability · Refrigeration and Air Conditioning Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (5)

Show source-provided references
1. Bloch · 1994
2. Failure analysis and prevention, vol. 11, ASM handbook, ASM; 2002. p. 628.
3. Brooks · 1993
4. Pelloux RM, Warren AS. Fatigue striations and failure analysis. In: International conference and exhibits on failure analysis, 8–11 July 1991, Canada, p. 45–9.
5. Hertzberg · 1996