Failure analysis of a lift gear shaft: Application of the FITNET FFS procedure fatigue module
Source abstract
Abstract
Abstract This paper analyses the failure of a lift gear shaft, which happened when the lift was carrying three people. Fortunately, the safety systems worked and there were no serious injuries, but the authorities demanded an investigation into the causes of the accident. The analysis was performed using the FITNET FFS fatigue module, and improper working conditions have been identified as the major cause of the accident.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Mechanical Failure Analysis and Simulation · Machine Fault Diagnosis Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (8)
Show source-provided references
1. Failure analysis of a diesel engine gear shaft10.1016/j.engfailanal.2005.10.015 ↗
2. Ping JJ, Guang M. Investigation on the failure of the gear shaft connected to extruder. Eng Fail Anal, in press, Available online 26 January 2007, doi:10.1016/j.engfailanal.2007.01.010.10.1016/j.engfailanal.2007.01.010 ↗
3. Analysis of a shrink-fit failure on a gear hub/shaft assembly10.1016/j.engfailanal.2006.03.008 ↗
4. FITNET FFS Procedure (Draft MK8). Prepared by European Fitness for Service Thematic Network, contract GIRT-CT-2001-05071, 5th European Framework, 2006.
5. UNE 36011:1975. Aceros no aleados para temple y revenido.
6. EN 10132-3: 2000. Cold rolled narrow steel strip for heat treatment. Technical delivery conditions. Steels for quenching and tempering.
7. 2003
8. DIN 4768 1990-5. Ermittlung der Rauhigkeitskenngrößen Ra, Rz, Rmax mit elektrischenTastschnittgeräten; Begriffe, Meßbedingungen. Beuth-Verlag, Berlin.