journal article·2019-10

Progressive structural deterioration of an endodontic instrument – A preliminary micro-computed tomography study

Igor Bastos Barbosa, Pantaleo Scelza, André Maues Brabo Pereira, Fabiano Guerra Ferreira, Rodrigo Bagueira, Caroline Sousa Ribeiro Adeodato, Miriam Zaccaro Scelza

Publisher page

Abstract

Abstract The aim of this study was to investigate the methodological potential of a new application of micro-computed tomography in providing an external and internal assessment of the structural integrity of an endodontic test file, and its progressive structural deterioration after repeated use in simulated root canals (resin blocks), until fracture. The progressive deterioration of the instrument was observed, and the external and internal defects were described. Radiolucent images suggestive of micro-cavities were observed in the instrument's core prior to its first use, and the formation and subsequent propagation of cracks in an apparently non-linear manner were observed after consecutive uses, until the final collapse of the whole structure. This novel assessment method allowed the visualization the external surface and the core of the same instrument at different time points in the instrumentation process, thus enabling researchers to identify where the cracks started and their progression during the course of instrument use.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Endodontics and Root Canal Treatments · Dental Radiography and Imaging · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (31)

Show source-provided references
1. Defects in ProTaper S1 instruments after clinical use: longitudinal examination10.1111/j.1365-2591.2005.00991.x ↗
2. Mechanical properties of nickel-titanium rotary instruments produced with a new manufacturing technique10.1111/j.1365-2591.2010.01835.x ↗
3. Cyclic fatigue of Reciproc and WaveOne reciprocating instruments10.1111/j.1365-2591.2012.02015.x ↗
4. Dowling · 2013
5. Canal preparation using only one Ni-Ti rotary instrument: preliminary observations10.1111/j.1365-2591.2007.01351.x ↗
6. Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement10.1111/j.1365-2591.2010.01756.x ↗
7. Lifespan of one nickel-titanium rotary file with reciprocating motion in curved root canals10.1016/j.joen.2010.08.040 ↗
8. Movement kinematics and cyclic fatigue of NiTi rotary instruments: a systematic review10.1111/iej.12613 ↗
9. Deformation and fracture incidence of Reciproc instruments: a clinical evaluation10.1111/iej.12302 ↗
10. Fracture incidence of WaveOne and Reciproc files during root canal preparation of up to 3 posterior teeth: a prospective clinical study10.1016/j.joen.2016.12.024 ↗
11. Scanning electron microscope observations of new and used nikel-titanium rotary files10.1097/00004770-200310000-00014 ↗
12. Characterizing fatigue response of nickel titanium alloys by rotary beam testing10.1520/JAI100390 ↗
13. Fatigue testing of controlled memory wire nickel-titanium rotary instruments10.1016/j.joen.2011.03.023 ↗
14. Surface characteristics of reciprocating instruments before and after use—a SEM analysis10.1590/0103-6440201300208 ↗
15. Three-dimensional measurement of enamel loss caused by bonding and debonding of orthodontic brackets10.1016/S0889-5406(97)70232-4 ↗
16. Quantifying and qualifying surface changes on dental hard tissues in vitro10.1016/j.jdent.2010.01.002 ↗
17. Atomic force microscopy of biomaterials surfaces and interfaces10.1016/S0039-6028(01)01296-1 ↗
18. Evaluation of the surface characteristics of used and new ProTaper instruments: an atomic force microscopy study10.1016/j.joen.2007.07.014 ↗
19. Evaluation of surface alterations in different retreatment nickel-titanium files: AFM and SEM study10.1002/jemt.22481 ↗
20. Qualitative and quantitative evaluation of human dental enamel after bracket debonding: a noncontact three-dimensional optical profilometry analysis10.1007/s00784-013-1159-0 ↗
21. A new method for the assessment of the surface topography of NiTi rotary instruments10.1111/iej.12707 ↗
22. A new method for the model-independent assessment of thickness in three-dimensional images10.1046/j.1365-2818.1997.1340694.x ↗
23. State of the art of micro-CT applications in dental research10.4248/IJOS09031 ↗
24. Characterization of titanium implant through micro CT10.1016/j.nima.2007.04.067 ↗
25. X-ray computed microtomography of internal damage in fiber reinforced polymer matrix composites10.1016/j.compscitech.2005.05.014 ↗
26. Micro-computed tomographic assessment on the effect of ProTaper Next and Twisted File Adaptive systems on dentinal cracks10.1016/j.joen.2015.02.012 ↗
27. A comparison of canal preparation in straight and curved root canals10.1016/0030-4220(71)90230-1 ↗
28. Canal shaping with WaveOne Primary reciprocating files and Pro Taper system: a comparative study10.1016/j.joen.2011.12.040 ↗
29. Reason for the transition of fatigue crack initiation site from surface to subsurface inclusions in high-strength steels
30. Assessment of geometrical characteristics of dental endodontic micro-instruments utilizing X-ray micro computed tomography10.1590/S1678-77572012000600011 ↗
31. Validated finite element analyses of WaveOne endodontic instruments: a comparison between M-Wire and NiTi alloys10.1111/iej.12333 ↗