Movable hood tube in LD convertor: Failure analysis and coating solution
Source abstract
Abstract
Abstract An assembly of movable and fixed hood tubes provide safe passage to LD gas produced during primary steel making process. These water-cooled tubes, made up of ASTM A106 : Grade B steel are exposed to most extreme environment involving severe thermal cycling, corrosion from hot LD gas as well as cooling water, wear and erosion from lime and slag splashing, etc. Current work analyzed the failure of movable tubes that led to generation of multiple cracks on the outer surface of the tube facing the LD gas. Analysis revealed cracks parallel to each other in circumferential direction of the tubes. Most of the cracks originated from outer wall of the tube and propagated inwards, however, some of the cracks emanated from inner wall which was in contact with cooling water as well. Elemental analysis revealed the presence of calcium, potassium and sulphur in the oxide scale along the cracks. The nature of scale was confirmed using Energy Dispersive Spectroscopy and Raman Spectroscopy. Presence of these elements are known to reduce the thermal conductivity of the scale and thus can make the cooling inefficient and promote greater thermal stresses. A number of circumferential and longitudinal cracks were observed in tube-to-tube weld zone as well and these were related to microstructural abnormality therein. Overall failure analysis suggested that “thermo-mechanical corrosion fatigue” resulted in premature failure of the hood tubes. Based on detailed laboratory study and field trial, Inconel 625 coating using twin wire thermal spray method has been proposed as a viable techno-economic solution for improved reliability of these tubes.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Metallurgical Processes and Thermodynamics · Corrosion Behavior and Inhibition · Hydrogen embrittlement and corrosion behaviors in metals
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (23)
Show source-provided references
1. Characteristics and sensing properties of CO gas sensors based on LaCo1 − xFexO3 nanoparticles10.1016/j.ssi.2017.02.021 ↗
2. Overview of Standards for CO Detection Products · 2019
3. Geminate recombination in carboxy hemoglobin A and its relation to overall carbon monoxide reactivity10.1016/0022-2836(84)90310-3 ↗
4. A case study on failure of superheater tubes in an industrial power plant10.1016/j.engfailanal.2017.07.007 ↗
5. Failure analysis of a superheater tube ruptured in a power plant boiler: Main causes and preventive strategies10.1016/j.engfailanal.2019.01.016 ↗
6. Metallography in life assessment of power plants10.1016/S1044-5803(96)00045-9 ↗
7. The structure and properties of 1%Cr – 0.5%Mo steel after service in CEGB power stations
8. Boiler tube failures: Some case studies
9. Mathematical modeling of thermal stresses in basic oxygen furnace hood tubes10.1007/BF02679716 ↗
10. ASTM A-106 · 2011
11. Howes · 1976 · 86
12. Spera · 1976 · 3
13. Thermal fatigue and corrosion fatigue in heat recovery area wall side tubes10.1016/j.engfailanal.2009.06.014 ↗
14. Failure of ASTM A-106 Gr. B tubes by creep and erosive wear10.1016/j.engfailanal.2012.08.005 ↗
15. One-way fluid structure interaction modelling methodology for boiler tube fatigue failure10.1016/j.engfailanal.2014.10.012 ↗
16. Corrosion · 1987 · vol. 13
17. Failure Analysis and Prevention · 1986 · vol. 11
18. Port · 1991
19. de Faria · J Raman Spectrosc · 1997 · 28 · 87310.1002/(SICI)1097-4555(199711)28:11<873::AID-JRS177>3.0.CO;2-B ↗
20. Matthews · 2010 · vol. 10 · 1267
21. Burnell-Gray · 2004 · p89
22. Tribological properties of twin wire arc spray coated aluminum cylinder liner10.1016/j.matdes.2015.06.122 ↗
23. Xu · 2011