Failure analysis of heat exchanger fluid vapor phase vent lines in a Polyester plant
Source abstract
Abstract
Abstract A Polyester plant is using Proprietary heat exchange fluids (26.5% biphenyl, 73.5% diphenyloxide). The plant hot condensate tank, condensate feed tank, and heat exchanger vapor phase dead end and ventable lines (ASTM 106 Grade B) with isolation valves were suffering frequent leakages with severe gouging and pitting corrosion. Lustrous (shiny) coke deposit was prominent inside the cut sections due to coke formation by low boiler products. Some adhered brown iron oxide (rust) deposits were also visible. A sludge sample was analyzed by XRD which revealed that carbon was the major constituent with γ-Maghemite-C (an iron oxide) as second mineral in order of abundance. The failure was diagnosed as severe localized corrosion and gouging at temperatures of about 200 °C and 53 psi by non-condensable low boilers decomposed corrosive products. The remedy was suggested which has been validated over the 2 years trouble free performance.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Hydrogen embrittlement and corrosion behaviors in metals · Corrosion Behavior and Inhibition · Material Properties and Failure Mechanisms
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (6)
Show source-provided references
1. St. Louis, Missouri. Therminol information Bulletin No. 1 to No. 6, 63166-6760 (314) 674-1000.
2. Dowtherm A – synthetic organic heat transfer fluid–liquid and vapor phase data, global areas. Tel.: +1 989 832 1560; fax: +1 989 832 1465.
3. Engineering manual for dowtherm heat transfer fluids. Tel.: +1 989 832 1560; fax: +1 989 832 1465.
4. Dowtherm A – heat transfer fluid, Sarnia, Ontario, Canada N7T 7K7.
5. Budd Lee LW, Ploechinger Harold. Dow Chemical Co., November 01, 2003.
6. Moisture contamination in CP dow storage tank (a case study). Ontario, Canada N7T 7K7: Dowtherm Sarnia.