Research on the function failure of accelerometer servo circuit caused by hydrolysis and corrosion
Source abstract
Abstract
Abstract This paper studied the function failure of a quartz flexible accelerometer servo circuit manufactured by a thick-film hybrid integrated process. The circuit adopts the epoxy glue bonding process of the metal shell and the ceramic cover plate to encapsulate, and it is a non-airtight package. After the circuit is powered on, the quiescent current output is abnormal, and the DC voltage output is constant high potential, the acceleration detection function cannot be realized. In response to this phenomenon, the fault tree method is used to locate the failure location, and the fault is located at the abnormal function of the differential capacitor voltage converter chip. Using microscopic analysis and characterization methods, it can be seen that the hydrolysis and corrosion of the surface of differential capacitance-to-voltage converter chip causes leakage in the active area inside the chip, leads to the function failure of the circuit. The above research is of great significance to the design, storage and application of non-hermetic hybrid integrated circuits.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Synthesis and properties of polymers · Advanced Sensor and Energy Harvesting Materials · Nanofabrication and Lithography Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (9)
Show source-provided references
1. The Development and Calibration of Quartz Accelerometers
2. Zhou Feng, Xu Ling. Servo circuit of quartz flexible accelerometer: CN, CN201749128 U[P]. 2011.
3. A closed-loop detection circuit for quartz flexure accelerometer
4. Zhang X, Lv H, Liu X. Systematic Study on Failure Information of Thick Film Hybrid Integrated Circuit[C]// IEEE International Symposium on Physical and Failure Analysis of Integrated Circuits. 0.
5. Failure Analysis of Hybrid Integrated DC/DC Convert in High Accelerated Life Test
6. Temperature characteristics and error compensation for quartz flexible accelerometer10.1007/s11633-015-0899-5 ↗
7. Temperature Drift Compensation Based on Artificial Fish Swarm Algorithm for Quartz Flexible Accelerometer10.4028/www.scientific.net/AMM.513-517.4030 ↗
8. Advanced polyimide materials: Syntheses, physical properties and applications10.1016/j.progpolymsci.2012.02.005 ↗
9. Hydrolytic Degradation of Kapton Film. Journal of Plastic Film & Sheeting, 2007.