Influence of damage to a timber truss roof structure on the stress distribution in a 17th century brick masonry vault
Source abstract
Abstract
Church masonry buildings are among the most precious monuments of civil engineering and the world heritage. Their inspection usually represents a complex task, and the non-invasive testing methods are recommended to assess the structural condition. Although diagnostic methods performed ‘in situ’ are not always accurate, collecting data from different historic periods is useful to build a database for a further evaluation of such historic structures. This work describes the inspection of the historic 17th century church structure and a preliminary assessment of its safety. During an air raid on Poland in the first days of World War II (1939), the roof was burnt down, which caused collapse of two segments of the masonry vault, which were reconstructed in the 1940 s as a timber structure and a combined king-post roof truss with diagonal struts was built. Currently, the failure state of the timber truss has been recognised above the presbytery, where the tie-beam rests on the external wall and the saddle, which supports the main rafter of the king-post truss. The semi-destructive (SDT) and non-destructive (NDT) tests were used to determine the geometric and cross-sectional properties of the structure ‘in situ’ with the purpose to evaluate the safety state of the timber members and the brick masonry vault. The numerical, three-dimensional, FEM analysis showed that the safety of the timber roof was ensured only owing to the temporary support on the chancel arch and the additional load on the masonry vault did not pose a threat to its safety.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Masonry and Concrete Structural Analysis · Structural Analysis of Composite Materials · Building materials and conservation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (75)
Show source-provided references
1. Geometric and static analysis of the historical trusses in Roman Catholic Church of the Holy Kozma and Damian in the Abramová Village10.1515/cee-2015-0017 ↗
2. Proportional and structural analysis of the historical truss of Church of St Bartholomew in Mladočov10.2478/cee-2021-0069 ↗
3. Failure analysis of church towers and roof structures due to high wind velocities10.1016/j.engfailanal.2019.02.046 ↗
4. I. Kirizsán, A. Tudoreanu-Crișan, A Sustainable Approach to Reconstruction: Historical Roof Structure Interventions, Sustainability 2024, Vol. 16, Page 4325 16 (2024) 4325. https://doi.org/10.3390/SU16114325.10.3390/su16114325 ↗
5. Technique at the service of a new liturgical model: the timber roof of the church of Saints Marcellino and Pietro in Cremona10.30682/tema08SIl ↗
6. Galileo was wrong: the geometrical design of masonry arches10.1007/s00004-006-0016-8 ↗
7. D. Cacace, G. De Matteis, Typological classification of vaulted structures in masonry churches, (2018). https://www.researchgate.net/publication/330761268 (accessed January 27, 2025).
8. S. Holzer, Numerical arch and vault analysis, Wiadomości Konserwatorskie (2013). https://www.academia.edu/126107057/Numerical_arch_and_vault_analysis (accessed January 27, 2025).
9. Masonry arches: historical rules and modern mechanics10.1080/15583050701312926 ↗
10. Hinging mechanisms of masonry single-nave barrel vaults subjected to lateral and gravity loads10.1061/(ASCE)ST.1943-541X.0001762 ↗
11. Funicular analysis of masonry vaults10.1016/S0045-7949(98)00279-X ↗
12. Collapse analysis of slender masonry barrel vaults10.1016/j.engstruct.2016.03.016 ↗
13. The masonry buttressed arch on spreading support10.1016/j.istruc.2019.03.008 ↗
14. Masonry vaulted structures under spreading supports: analyses of fracturing behavior and size effect
15. The safety of masonry arches10.1016/0020-7403(69)90070-8 ↗
16. Lateral loads carrying capacity and minimum thickness of circular and pointed masonry arches10.1016/j.ijmecsci.2016.07.015 ↗
17. On the construction stage analysis of historical masonry vaults
18. A. Gros, A. Guillem, L. De Luca, É. Baillieul, B. Duvocelle, O. Malavergne, L. Leroux, T. Zimmer, Faceting the post-disaster built heritage reconstruction process within the digital twin framework for Notre-Dame de Paris, Scientific Reports 2023 13:1 13 (2023) 1–12. https://doi.org/10.1038/s41598-023-32504-9.10.1038/s41598-023-32504-9 ↗
19. Analysis and management of structural deformations through parametric models and HBIM workflow in architectural heritage
20. Reverse engineering as a non-invasive examining method of the water tower brick structure condition10.1016/j.engfailanal.2024.108280 ↗
21. Evaluation of records using terrestrial laser scanner in architectural heritage for information modeling in HBIM construction: the case study of the La Anunciación church (Seville)
22. From scan-to-BIM to a structural finite elements model of built heritage for dynamic simulation10.1016/j.autcon.2022.104518 ↗
23. Semantic interoperability for cultural heritage conservation: workflow from ontologies to a tool for managing and sharing data
24. An historical building information modelling approach for the preventive conservation of historical constructions: application to the Historical Library of Salamanca10.1016/j.autcon.2020.103449 ↗
25. Historical masonry building aggregates: advanced numerical insight for an effective seismic assessment on two row housing compounds10.1016/j.engstruct.2019.04.025 ↗
26. The new foundation system of the Basilica di Collemaggio’s transept
27. M. Zucca, E. Reccia, E. Vecchi, V. Pintus, A. Dessì, A. Cazzani, An Evaluation of the Structural Behaviour of Historic Buildings Under Seismic Action: A Multidisciplinary Approach Using Two Case Studies, Applied Sciences 2024, Vol. 14, Page 10274 14 (2024) 10274. https://doi.org/10.3390/APP142210274.10.3390/app142210274 ↗
28. P.B. Lourenço, The ICOMOS methodology for conservation of cultural heritage buildings: Concepts, research and application to case studies, (2014) 945–954. https://doi.org/10.14575/GL/REHAB2014/095.10.14575/gl/rehab2014/095 ↗
29. Non-destructive testing of wooden elements in historic buildings - an example of testing a 19th century roof truss structure10.59440/ceer/190825 ↗
30. Restrictions and new possibilities of technical and conservation diagnostics of wood in heritage buildings10.59440/ceer/174568 ↗
31. In situ assessment of structural timber using the resistance drilling method – evaluation of usefulness10.1016/j.conbuildmat.2015.11.004 ↗
32. Reliability analysis of a timber truss system subjected to decay10.1016/j.engstruct.2012.07.022 ↗
33. Efficiency of visual and machine strength grading of sawn timber with respect to log type10.3390/f12111467 ↗
34. Methods of strength grading of structural timber-comparative analysis of visual and machine grading on the example of scots pine timber from four natural forest regions of
35. Evaluation of the historic wooden structure condition based on the results of non-destructive tests10.1016/j.engfailanal.2024.108116 ↗
36. M. Stepinac, T. Kišiček, I. Lukačevi, I. Duvnjak, J. Sola-Caraballo, J. María Rincón-Calderón, C. Rivera-Gómez, J. Antonio López-Martínez, C. Galán-Marín, On-Site Risk Assessment Methodology of Historic Timber Structures: The Case Study of Santa Cruz Church, Buildings 2022, Vol. 12, Page 935 12 (2022) 935. https://doi.org/10.3390/BUILDINGS12070935.10.3390/buildings12070935 ↗
37. A study on the structural functioning of the ancient charpente of Notre-Dame, with a historical perspective10.1016/j.culher.2021.02.007 ↗
38. The roof of the Church of the Nativity in Bethlehem: structural problems and intervention techniques10.1016/j.culher.2012.10.013 ↗
39. Defects and failures of joints of historic roof trusses and possibilities of using FRP materials in their rehabilitation and stabilization10.14311/CEJ.2015.03.0018 ↗
40. M. Corradi, A.I. Osofero, A. Borri, Repair and Reinforcement of Historic Timber Structures with Stainless Steel—A Review, Metals 2019, Vol. 9, Page 106 9 (2019) 106. https://doi.org/10.3390/MET9010106.10.3390/met9010106 ↗
41. Correlation between sonic pulse velocity and flat-jack tests for the estimation of the elastic properties of unreinforced brick masonry: case studies from Croatia
42. Calibration of sonic pulse velocity tests for detection of variable conditions in masonry walls10.1016/j.conbuildmat.2018.10.073 ↗
43. S. Santos-Assunçao, V. Perez-Gracia, O. Caselles, J. Clapes, V. Salinas, Assessment of Complex Masonry Structures with GPR Compared to Other Non-Destructive Testing Studies, Remote Sensing 2014, Vol. 6, Pages 8220-8237 6 (2014) 8220–8237. https://doi.org/10.3390/RS6098220.10.3390/rs6098220 ↗
44. Evaluation of non-destructive techniques for mechanical characterisation of earth-based mortars in masonry joints10.1016/j.conbuildmat.2023.131960 ↗
45. D. Bajno, K. Schabowicz, A. Grzybowska, Material Testing of Historic Bricks and Mortars in Degraded Masonry Structures, Materials 2024, Vol. 17, Page 3192 17 (2024) 3192. https://doi.org/10.3390/MA17133192.10.3390/ma17133192 ↗
46. G.M. Mengistu, Z. Gyurkó, R. Nemes, The Influence of the Rebound Hammer Test Location on the Estimation of Compressive Strength of a Historical Solid Clay Brick, Solids 2023, Vol. 4, Pages 71-86 4 (2023) 71–86. https://doi.org/10.3390/SOLIDS4010005.10.3390/solids4010005 ↗
47. Compressive strength of solid clay brickwork of masonry bridges: estimate through Schmidt Hammer tests10.1016/j.conbuildmat.2021.124494 ↗
48. A. Brencich, E. Sterpi, Compressive strength of solid clay brick masonry: calibration of experimental tests and theoretical issues, in: P.B. Lourenço, P. Roca, C. Modena, S. Agrawal (Eds.), 5th International Conference: Structural Analysis of Historical Constructions (SAHC), New Delhi, 2006.
49. RILEM TC 127-MS: Tests for masonry materials and structures. Recommendations, (2005).
50. M.S. Donduren, O. Ali, Comparison of the Masonry Building Codes Turkish, Euro and USA Building Codes, Journal of International Environmental Application and Science 13 (2018) 89–96. https://dergipark.org.tr/en/pub/jieas/issue/40161/477368 (accessed April 8, 2025).
51. PN-EN 1996-1-1:2023-08; Eurocode 6: Design of masonry structures - Part 1-1: General rules for reinforced and unreinforced masonry structures, 2023.
52. A novel approach for modelling a historic timber roof10.1080/20426445.2023.2171895 ↗
53. Historic timber roof structure vulnerability assessment procedures – critical analysis and comparison10.1016/j.culher.2023.11.011 ↗
54. Selected methods of diagnosis of historic timber structures – principles and possibilities of assessment
55. Structural analysis of two King-post timber trusses: non-destructive evaluation and load-carrying tests10.1016/j.conbuildmat.2009.08.025 ↗
56. Stan zachowania więźby storczykowej nad budynkiem kościoła po przeszło trzystu latach eksploatacji10.15199/33.2019.06.02 ↗
57. Effects of brick pattern on the static behavior of masonry vaults10.1080/15583058.2021.1874565 ↗
58. A parametric model for ribbed masonry vaults10.1016/j.autcon.2019.03.006 ↗
59. Numerical analysis of the mechanical role of the ribs in groin vaults10.1016/j.compstruc.2015.05.032 ↗
60. Load capacity proof of a rib vault, rebuilt based on a historical model10.1002/cepa.968 ↗
61. Leica Cyclone REGISTER 360 PLUS | Leica Geosystems, (n.d.). https://leica-geosystems.com/products/laser-scanners/software/leica-cyclone/leica-cyclone-register-360 (accessed February 10, 2025).
62. LBC 3D SCAN Maciej Luboiński, Cyclone REGISTER 360 Registration Report, 2023.
63. Leica TruView Desktop | Leica Geosystems, (n.d.). https://leica-geosystems.com/en-gb/products/laser-scanners/software/leica-truview-digital-reality-viewer/leica-truview-desktop (accessed February 10, 2025).
64. Semi-destructive and non-destructive tests of timber structure of various moisture contents10.3390/ma14010096 ↗
65. PN-EN 1995-1-1:2010/NA:2010; Eurocode 5: Design of timber structures - Part 1-1: General - Common rules and rules for buildings (in Polish), 2010.
66. PN-EN 338:2016-06; Structural timber - Strength classes, 2016.
67. Matysek · 2014
68. Łątka · 2023
69. Materialeigenschaften historischen Ziegelmauerwerks im Hinblick auf Tragfähigkeitsberechnungen am Beispiel der Leipziger Bundwand10.1002/dama.200200530 ↗
70. IRS 70778-3; Recommendations for the inspection, assessment and maintenance of masonry arch bridges, UIC Communications, 2020.
71. AxisVM Products - AXISVM, (n.d.). https://axisvm.eu/axisvm-products/ (accessed February 11, 2025).
72. PN-EN 1990:2004/NA:2010; Eurocode - Basis of structural design (in Polish), 2010.
73. PN-EN 1991-1-1:2004/NA:2010; Eurocode 1: Actions on structures - Part 1-1: General actions - Densities, self-weight, imposed loads for buildings (in Polish), 2010.
74. PN-EN 1991-1-3:2005/NA:2010; Eurocode 1: Actions on structures - Part 1-3: General actions - Snow loads (in Polish), 2010.
75. PN-EN 1991-1-4:2008/NA:2010; Eurocode 1: Actions on structures - Part 1-4: General actions - Wind actions (in Polish), 2010.