journal article·2008-10

An experimental and numerical study of the effect of friction in single dowel joints

Johan Sjödin, Erik Serrano, Bertil Enquist

Holz als Roh- und Werkstoff· Volume 66· Issue 5
Publisher page

Abstract

The effect of friction between the dowel and the surrounding timber was studied for single dowel-type joints. The joints tested were divided into two groups of joints, where the surface of the dowels differed. For the first group, the dowels had a smooth surface and for the second group the dowels had a rough surface. A contact-free measurement technique was used in the experimental investigation. In addition to that, numerical simulations were carried out aimed at predicting the load-bearing capacity of the joints tested as well as estimating the coefficient of friction between the dowel and the surrounding timber.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Wood Treatment and Properties · Mechanical Behavior of Composites · Asphalt Pavement Performance Evaluation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (18)

Show source-provided references
1. ABAQUS Inc (2004) ABAQUS/Standard and ABAQUS/CAE Version 6.5, User Manuals
2. Aicher S, Gustafsson PJ (ed), Haller P, Petersson H (2002) Fracture mechanics models for strength analysis of timber beams with a hole or a notch – a report of RILEM TC-133. Report TVSM-7134, Lund University, Sweden
3. Blaß HJ (2003) Joints with dowel-type fasteners. In: Thelandersson S, Larsen HJ (eds) Timber Engineering. Wiley & Sons, Chichester, England, pp 315–331
4. Daudeville L, Davenne L, Yasumura M (1999) Prediction of the load carrying capacity of bolted timber joints. Wood Sci Technol 33(1):15–2910.1007/s002260050095 ↗
5. Davenne L, Daudeville L, Yasumura M (1996) Failure of doweled joints loaded parallel to the grain: experiment and simulation. Proceedings of the CIB W18 Meeting, paper CIB-W18/29-7-8
6. Dinwoodie JM (2000) Timber: Its nature and behavior. Second edition, E & FN Spon, London10.4324/9780203477878 ↗
7. Eurocode 5 (2004) Eurocode 5 – Design of timber structures. EN 1995-1-1:2004(E)
8. European standard (1993) EN 383:1993 Timber structures – Test methods. Determination of embedding strength and foundation values for dowel type fasteners
9. Gustafsson PJ (2002) Mean stress approach and initial crack approach. In: Aicher S, Gustafsson PJ (ed) Haller P and Petersson H Fracture mechanics models for strength analysis of timber beams with a hole or a notch – a report of RILEM TC-133. Report TVSM-7134, Lund University, Sweden
10. Gustafsson PJ (2003) Fracture perpendicular to the grain – structural applications. In: Thelandersson S, Larsen HJ (eds) Timber Engineering. Wiley & Sons, Chichester, England, pp 103–130
11. Johansen KW (1949) Theory of timber connections. Int Assoc Bridge Struc Eng 9:249–262
12. Jorissen A (1998) Double shear timber connections with dowel type fasteners, Delft University Press, ISBN 90-407-1783-4
13. Rodd PD (1973) The analysis of timber joints made with circular dowel connectors. Ph D thesis, University of Sussex, England
14. Schmid M, Blaß HJ, Frasson RPM (2002) Effect of distances, spacing and number of dowels in a row on the load carrying capacity of connections with dowels failing by splitting. Proceedings of the CIB W18 Meeting, paper CIB-W18/31-9-1, Kyoto, Japan
15. Serrano E, Enquist B (2005) Contact-free measurement and non-linear finite element analyses of strain distribution along wood adhesive bonds. Holzforschung 59(6):641–64610.1515/HF.2005.103 ↗
16. Serrano E, Gustafsson PJ (2006) Fracture mechanics in timber engineering – Strength analyses of components and joints. Mater Struct 40:87–9610.1617/s11527-006-9121-0 ↗
17. Siem J (1999) Capacity and ductility of dowel connections in timber structures (In Norwegian). Ph.D. thesis, Norwegian University of Science and Technology, 1999:46, Trondheim, Norway
18. Sjödin J, Serrano E, Enquist B (2006) Contact-free measurements and numerical analyses of the strain distribution in the joint area of steel-to-timber dowel joints. Holz Roh- Werkst 64:497–50610.1007/s00107-006-0112-1 ↗