Experimental assessment of the pull-out strength of single rods bonded in glulam parallel to the grain
Source abstract
Abstract
The use of glued-in rods is a very efficient technique for connecting timber elements either in restoration or in the construction of new structures. It has been used for about 30 years in several countries all over the world. However, despite multiple research efforts, there is still a lack of consensus on a standard method to design such connections and to compute their carrying capacity. If a company wishes to include this system in its design possibilities, it has to validate it by testing. This paper reports on the results of a test program aiming at situating the glued-in rod connecting technique of the Belgian glulam company Lamcol with the main existing design methods. A total of 60 specimens of glued-in rod joints were tested in pull-pull configuration. The varying parameters were the anchoring length and the rod diameter. The rods were threaded steel bars. They were bonded into glulam Norway spruce lamellas parallel to the grain by means of an epoxy-type adhesive injection. The preparation of the specimens was kept very simple, as close as possible to the actual production technique of the company. The main difference with previously reported test results comes from the failure modes. Failure occurred mainly by splitting of the wood element along the anchorage although the standard recommendations for the distance between the rods and the edges of the specimens were respected. Two strength models are derived empirically from the analysis of the test results which are also compared with predictions from computation methods proposed in the literature.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Wood Treatment and Properties · Structural Engineering and Vibration Analysis · Tree Root and Stability Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (29)
Show source-provided references
1. Aicher S, Dill-Langer G (2001) Influence of moisture and load duration on performance of glued-in rods. Proceedings of the RILEM Symposium on Joints in Timber Structures, Stuttgart, p 383–392
2. Aicher S, Wolf G, Dill-Langer G (1998) Heat flow in glulam joist with a glued-in steel rod subjected to variable ambient temperature. Otto Graf J 9:205–217
3. Aicher S, Herr J (1997) Bonded glulam-steel rod connections with long anchorage length. Otto Graf J 8:232–254
4. Ansell MP, Madhoushi R (2004) Experimental study of static and fatigue strengths of pultruded GFRP rods bonded into LVL and glulam. Int J Adhes Adhes 24:319–32510.1016/j.ijadhadh.2003.07.004 ↗
5. Bainbridge RJ, Mettem CJ, Harvey K, Ansell MP (2002) Bonded-in rod connections for timber structures – development of design methods and test observations. Int J Adhes Adhes 22:47–5910.1016/S0143-7496(01)00036-7 ↗
6. Bainbridge RJ, Harvey K, Mettem CJ, Ansell MP (2000) Fatigue performance of bonded-in rods in glulam, using three adhesive Types. Proceedings of International Council For Building Research Studies And Documentation, Working Commission W18 – Timber Structures, Meeting 33, Delft
7. Bengtsson C, Johansson CJ (2001) GIROD – Glued-in rods for timber structures. Report SP 2002:26, Swedish National Testing and Research Institute, Venezia
8. Blass HJ, Laskewitz B (1999) Effect of spacing and edge distance on the axial strength of glued-in rods. CIB W18 Meeting, paper 32-7-12
9. Broughton JG, Hutchinson AR (2001a) Pull-out behaviour of steel rods bonded into timber. Mater Struct 34:100–10910.1007/BF02481558 ↗
10. Broughton JG, Hutchinson AR (2001b) Adhesive systems for structural connections in timber. Int J Adhes Adhes 21:177–18610.1016/S0143-7496(00)00049-X ↗
11. Buchanan A, Moss P, Stuart H (2004) Fire resistance of epoxy-grouted steel rod connections in laminated veneer lumber (LVL). Master of Engineering in Fire Engineering, Department of Civil Engineering University of Canterbury
12. Connolly T, Mettem CJ (2003) Development of Eurocode-type design rules for axially loaded bonded-in rods. Report for project LICONS http://www.licons.org/documents/interimreports/07development-of-eurocode.pdf, last access 29 July 2008
13. Del Senno M, Piazza M, Tomasi R (2004) Axial glued-in steel timber joints – experimental and numerical analysis. Holz Roh- Werkst 62:137–14610.1007/s00107-003-0450-1 ↗
14. prEN 1995-2 Second draft (2003) Draft rules for bonded-in rods. Extract from: prEN 1995-2:2003, Eurocode 5 – Design of timber structures, Part 2: Bridges. http://www.licons.org/documents/inforesources/01draft-ec5.pdf, LICONS, last access 29 July 2008
15. Faye C, Millereux D, Morlier P (2005) Durée de vie des assemblages par goujons collés pour du lamellé collé sous sollicitations mécaniques et hygrothermiques. Rapport final, CTBA, France
16. Feligioni L, Lavisci P, Duchanois G, De Ciechi M, Spinelli P (2003) Influence of glue rheology and joint thickness on the strength of bonded-in rods. Holz Roh- Werkst 61:281–28710.1007/s00107-003-0387-4 ↗
17. Gardelle V, Morlier P (2007) Geometric parameters which affect the short term resistance of an axially loaded glued-in rod. Mater Struct 40:127–13810.1617/s11527-006-9155-3 ↗
18. Gerold M (1992) Verbund von Holz- und Gewindestangen aus Stahl. Bautechnik 4:167–178
19. Gustafsson PJ, Serrano E, Aicher S, Johansson CJ (2001) A Strength Design Equation for Glued-in Rods. Proceedings of the RILEM Symposium on Joints in Timber Structures, September 12–14, Stuttgart, p 323–332
20. Kemmsies M (1999) Comparison of pull-out strengths of 12 adhesives for glued-in rods for timber structures. Report SP 1999:20, Swedish National Testing and Research Institute
21. LEGNODOC (2003) Evaluation of draft design rules. Report for project LICONS, http://www.licons.org/documents/interimreports/03task5-3.pdf, last access 29 July 2008
22. Oksanen T, Kangas J (1999) Strength and fire resistance of connections based on glued in rods. VTT notes, Technical Research Centre of Finland, ESPOO
23. Pörtner C (2005) Untersuchungen zum Verbund zwischen eingeklebten stiftförmigen faserverstärkten Kunststoffen und Holz. Schriftenreihe Bauwerkserhaltung und Holzbau, Heft 2, Kassel University Press
24. Riberholt H (1986) Glued Bolts in Glulam – part I. Series R – no210, Department of structural Engineering, Technical University of Denmark
25. Riberholt H (1988) Glued Bolts in Glulam – part II. Series R – no228, Department of structural Engineering, Technical University of Denmark
26. Serrano E (2001) Glued-in rods for timber structures – an experimental study of softening behaviour. Mater Struct 34:228–23410.1007/BF02480593 ↗
27. Simonin (2006) Goujons collés RESIX. Avis Technique CSTB 3/05-453, France, http://tdb-atec.cstb.fr/fichiers/pdf/GS03-D/AD050453.PDF, last access 29 July 2008
28. Steiger R, Gehri E, Widmann R (2007) Pull-out strength of axially loaded steel rods bonded in glulam parallel to the grain. Mater Struct 40:69–7810.1617/s11527-006-9111-2 ↗
29. Townsend PK (1990) Steel dowels epoxy bonded in glue laminated timber. Technical report 90/11, Department of Civil Engineering, University of Canterbury, Christchurch, New Zealand