Experimental and numerical evaluation of hold-down connections on radiata pine Cross-Laminated-Timber shear walls: a case study in Chile
Source abstract
Abstract
Cross-Laminated-Timber (CLT) structures have gained popularity in the field of medium-rise buildings due to the quick fabrication and assembly of the panels. However, connections in radiata pine CLT shear walls and the behavior of CLT structures under lateral loads is still not well understood. In this context, this paper studies the structural behavior of hold-down connections on radiata pine CLT walls by means of experimental tests and numerical simulations under static and dynamic conditions. The test response of connections was replicated by calibrating two hysteretic models on OpenSees. The main results showed that applied models can reproduce the hysteretic behavior of hold-down connections with high precision. It was observed that hold-down connections on radiata pine CLT walls reached a loading capacity similar to other wood species, but the strength and stiffness degradation was quicker, and no significant difference with the parallel to grain capacity of angle bracket connections was noticed. In addition, it was found that radiata pine CLT walls can achieve suitable cyclic loading performance with low damage level in connections and reach high levels of displacement ductility. Finally, the importance of friction in the load capacity of the wall was also shown.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Tree Root and Stability Studies · Wood Treatment and Properties · Bamboo properties and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. Blass H, Fellmoser P (2004) Design of solid wood panels with cross layers. In: Proceedings of the 8th world conference on timber engineering, pp 1001–1006
2. Brandner R, Flatscher G, Ringhofer A, Schickhofer G, Thiel A (2016) Cross laminated timber (CLT): overview and development. Eur J Wood Prod 74(3):331–351. https://doi.org/10.1007/s00107-015-0999-510.1007/s00107-015-0999-5 ↗
3. Ceccotti A (2008) New Technologies for construction of medium-rise buildings in seismic regions: The XLAM case. Struct Eng Int 18:156–165. https://doi.org/10.2749/10168660878421868010.2749/101686608784218680 ↗
4. Ceccotti A, Sandhaas C, Okabe M et al (2013) SOFIE project—3D shaking table test on a seven-storey full-scale cross-laminated timber building. Earthq Engng Struct Dyn 42:2003–2021. https://doi.org/10.1002/eqe.230910.1002/eqe.2309 ↗
5. EN 12512 (2001) Timber structures—test methods—cyclic testing of joints made with mechanical fasteners. CEN, Brussels, Belgium
6. EN 338:2016 (2016) Structural timber—strength classes. CEN, Brussels, Belgium
7. Flatscher G, Bratulic K, Schickhofer G (2015) Experimental tests on cross-laminated timber joints and walls. Proc ICE Struct Build, 168(11): 868–877. https://doi.org/10.1680/stbu.13.0008510.1680/stbu.13.00085 ↗
8. Folz B, Filiatrault A (2002) SAWS—Seismic Analysis of Woodframe Structures, Version 1.0, CUREE Publication No. W-21, Richmond, CA
9. Gavric I, Fragiacomo M, Ceccotti A (2015a) Cyclic behavior of typical screwed connections for cross-laminated (CLT) structures. Eur J Wood Prod 73:179–191. https://doi.org/10.1007/s00107-014-0877-610.1007/s00107-014-0877-6 ↗
10. Gavric I, Fragiacomo M, Ceccotti A (2015b) Cyclic behaviour of typical metal connectors for cross-laminated (CLT) structures. Mater Struct 48:1841–1857. https://doi.org/10.1617/s11527-014-0278-710.1617/s11527-014-0278-7 ↗
11. Hristovski V, Dujic B, Stojmanovska M, Mircevska V (2013) Full-scale shaking-table tests of xlam panel systems and numerical verification: specimen 1. J Struct Eng 139:2010–2018. https://doi.org/10.1061/(ASCE)ST.1943-541X.000075410.1061/(ASCE)ST.1943-541X.0000754 ↗
12. Izzi M, Rinaldin G, Polastri A, Fragiacomo M (2018a) A hysteresis model for timber joints with dowel-type fasteners. Eng Struct 157:170–178. https://doi.org/10.1016/j.engstruct.2017.12.01110.1016/j.engstruct.2017.12.011 ↗
13. Izzi M, Polastri A, Fragiacomo M (2018b) Modelling the mechanical behaviour of typical wall-to-floor connection systems for Cross-Laminated Timber structures. Eng Struct 162:270–282. https://doi.org/10.1016/j.engstruct.2018.02.04510.1016/j.engstruct.2018.02.045 ↗
14. Izzi M, Polastri A, Fragiacomo M (2018c) Investigating the hysteretic behavior of Cross-Laminated Timber wall systems due to connections. J Struct Eng. https://doi.org/10.1061/(ASCE)ST.1943-541X.000202210.1061/(ASCE)ST.1943-541X.0002022 ↗
15. Karacabeyli E, Douglas B (eds) (2013) Cross-Laminated Timber handbook, US EDITION. FPInnovations, Poitn-Claire
16. Krawinkler H, Parisi F, Ibarra L, Ayoub A, Medina R (2001) Development of a testing protocol for woodframe structures. CUREE Consortium of Universities for Research in Earthquake Engineering, Richmond
17. Latour M, Rizzano G (2017) Seismic behavior of cross-laminated timber panel buildings equipped with traditional and innovative connectors. Arch Civ Mech Eng 17:382–399. https://doi.org/10.1016/j.acme.2016.11.00810.1016/j.acme.2016.11.008 ↗
18. Lowes L, Mitra N, Altoontash A (2004) A Beam-Column Joint Model for Simulating the Earthquake Response of Reinforced Concrete Frames. In: PEER Report 2003/10. Pacific Earthquake Engineering Research Center, College of Engineering, University of California, Barkely
19. McKenna F, Fenves G, Filippou F, Mazzoni S, Scott M, Elgamal A, Yang Z, Lu J, Arduino P, McKenzie P, Deierlein G, Law K (2006) OpenSees. University of California, Barkely
20. Pei S, van de Lindt JW, Popovski M et al (2016) Cross-Laminated Timber for Seismic Regions: Progress and Challenges for Research and Implementation. J Struct Eng 142:E2514001. https://doi.org/10.1061/(ASCE)ST.1943-541X.000119210.1061/(ASCE)ST.1943-541X.0001192 ↗
21. Polastri A, Giongo I, Angeli A, Brandner R (2017) Mechanical characterization of a pre-fabricated connection system for cross laminated timber structures in seismic regions. Eng Struct. https://doi.org/10.1016/j.engstruct.2017.12.02210.1016/j.engstruct.2017.12.022 ↗
22. Popovski M, Gavric I (2016) Performance of a 2-story CLT house subjected to lateral loads. J Struct Eng 142:E4015006. https://doi.org/10.1061/(ASCE)ST.1943-541X.000131510.1061/(ASCE)ST.1943-541X.0001315 ↗
23. Rinaldin G, Amadio C, Fragiacomo M (2013) A component approach for the hysteretic behaviour of connections in cross-laminated wooden structures. Earthq Eng Struct Dyn 42:2023–2042. https://doi.org/10.1002/eqe.231010.1002/eqe.2310 ↗
24. Schneider J, Karacabeyli E, Popovski M, Stiemer SF, Tesfamariam S (2014) Damage assessment of connections used in Cross-Laminated Timber subject to cyclic loads. J Perform Constr Facil 28:A4014008. https://doi.org/10.1061/(ASCE)CF.1943-5509.000052810.1061/(ASCE)CF.1943-5509.0000528 ↗
25. Schneider J, Shen Y, Stiemer SF, Tesfamariam S (2015) Assessment and comparison of experimental and numerical model studies of cross-laminated timber mechanical connections under cyclic loading. Constr Build Mater 77:197–212. https://doi.org/10.1016/j.conbuildmat.2014.12.02910.1016/j.conbuildmat.2014.12.029 ↗
26. Shen Y-L, Schneider J, Tesfamariam S et al (2013) Hysteresis behavior of bracket connection in Cross-Laminated-Timber shear walls. Constr Build Mater 48:980–991. https://doi.org/10.1016/j.conbuildmat.2013.07.05010.1016/j.conbuildmat.2013.07.050 ↗
27. Tomasi R, Smith I (2015) Experimental characterization of monotonic and cyclic loading responses of CLT panel-to-foundation angle bracket connections. J Mater Civ Eng, 27(6): 04014189(1–10). https://doi.org/10.1061/(ASCE)MT.1943-5533.000114410.1061/(ASCE)MT.1943-5533.0001144 ↗
28. Yasumura M, Kobayashi K, Okabe M, Miyake T, Matsumoto K (2016) Full-scale tests and numerical analysis of low-rise CLT structures under lateral loading. J Struct Eng 142:E4015007 https://doi.org/10.1061/(ASCE)ST.1943-541X.000134810.1061/(ASCE)ST.1943-541X.0001348 ↗