Quantitative determination of bound water diffusion in multilayer boards by means of neutron imaging
Source abstract
Abstract
Diffusion processes into multilayered samples of Norway spruce (Picea abies [L.] Karst.) exposed to a differentiating climate (dry side/wet side) were determined and quantified by means of neutron imaging (NI). The experiments were carried out at the neutron imaging facility NEUTRA at the Paul Scherrer Institute (PSI) in Villigen (Switzerland). With NI the influence of different adhesives (polyvinyl acetate (PVAc), urea formaldehyde resin (UF), epoxy resin (EP), one-component polyurethane (1C PUR)) on the diffusion process could be determined by varying the layer number and the thickness of adhesive joints of the samples. Thereby, neutron transmission images were used to measure time dependent water profiles in the diffusion direction. Using Fick's second law, diffusion coefficients for radial and tangential water transport in spruce wood and in the adhesive joints were calculated depending on moisture content (MC). It was found that the diffusion coefficients of the adhesives (1C PUR, EP at high MC) were up to three orders of magnitude lower than those of spruce wood. PVAc and UF had a smaller barrier effect compared to wood, which in contrast to 1C PUR and EP, clearly depends on the MC. © The Author(s) 2010.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Wood Treatment and Properties · Cultural Heritage Materials Analysis · Building materials and conservation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (24)
Show source-provided references
1. Dunky M, Niemz P (2002) Holzwerkstoffe und Leime: Technologie und Einflussfaktoren. Springer, Berlin/Heidelberg10.1007/978-3-642-55938-9 ↗
2. Foglia A (2006) Untersuchungen zu ausgewählten Einflussfaktoren auf den Diffusionswiderstand von Holzwerkstoffen. Diploma thesis, ETH Zurich, Institute for Building Materials, Wood Physics, Zurich
3. Frandsen HL, Damkilde L, Svensson S (2007) A revised multi-Fickian moisture transport model to describe non-Fickian effects in wood. Holzforschung 61(5):563–57210.1515/HF.2007.085 ↗
4. Frühwald A (1973) Ein Beitrag zur Kenntnis des diffusionstechnischen Verhaltens von Furnierplatten und kunstharzbeschichtetem Holz. Dissertation, University of Hamburg, Hamburg
5. Glaser H (1959) Graphisches Verfahren zur Untersuchung von Diffusionsvorgängen. Kältetechnik 11(10):345–349
6. Hass P, Wittel FK, Mendoza M, Stampanoni M, Herrmann HJ, Niemz P (2010) Adhesive penetration in beech wood. Part I: Experiments. Wood Sci Technol (in press)10.1007/s00226-011-0410-6 ↗
7. Hassanein R (2006) Correction methods for the quantitative evaluation of thermal neutron tomography. Dissertation, ETH Zurich, Zurich
8. ISO 12572 (2001) Hygrothermal performance of building materials and products—determination of water vapour transmission properties. Geneva
9. Kollmann F, Côté WA Jr (1968) Principles of wood science and technology, vol I: Solid wood. Springer, Berlin/Heidelberg/New York10.1007/978-3-642-87928-9 ↗
10. Lehmann E, Vontobel P, Scherrer P, Niemz P (2001a) Application of neutron radiography as method in the analysis of wood. Holz Roh- Werkst 59(6):463–47110.1007/s00107-001-0259-8 ↗
11. Lehmann EH, Vontobel P, Wiezel L (2001b) Properties of the radiography facility NEUTRA at SINQ and its potential for Use as European reference facility. Nondestr Test Eval 16:191–20210.1080/10589750108953075 ↗
12. Liu JY (1989) A new method for separating diffusion coefficient and surface emission coefficient. Wood Fiber Sci 21(2):133–141
13. Mannes D, Niemz P, Lehmann E (2006) Study on the penetration behaviour of water in corner joints by means of neutron radiography. Wood Res 51(2):1–14
14. Mannes D, Josic L, Lehmann E, Niemz P (2009a) Neutron attenuation coefficients for non-invasive quantification of wood properties. Holzforschung 63(4):472–47810.1515/HF.2009.081 ↗
15. Mannes D, Sonderegger W, Hering S, Lehmann E, Niemz P (2009b) Non-destructive determination and quantification of diffusion processes in wood by means of neutron imaging. Holzforschung 63(5):589–59610.1515/HF.2009.100 ↗
16. Nelder JA, Mead R (1965) A simplex method for function minimization. Comput J 7(4):308–31310.1093/comjnl/7.4.308 ↗
17. Niemz P, Lehmann E, Vontobel P, Haller P, Hanschke S (2002) Investigations using neutron radiography for evaluations of moisture ingress into corner connections of wood. Holz Roh- Werkst 60(2):118–12610.1007/s00107-001-0260-2 ↗
18. Olek W, Weres J (2007) Effects of the method of identification of the diffusion coefficient on accuracy of modeling bound water transfer in wood. Transp Porous Med 66:135–14410.1007/s11242-006-9010-6 ↗
19. Siau JF (1995) Wood: influence of moisture on physical properties. Virginia Polytechnic Institute and State University, Keene
20. Skaar C (1988) Wood-water relations. Springer, Berlin/Heidelberg/New York10.1007/978-3-642-73683-4 ↗
21. Sonderegger W (2010) unpublished results
22. Stamm AJ (1959a) Bound-water diffusion into wood in the fiber direction. For Prod J 9(1):27–32
23. Stamm AJ (1959b) Bound-water diffusion into wood in across-the-fiber directions. For Prod J 10(10):524–528
24. Vanek M, Teischinger A (1989) Diffusionskoeffizienten und Diffusionswiderstandszahlen von verschiedenen Holzarten. Holzforsch Holzverwer 41(1):3–6