journal article·2006-04

Fire and bending properties of blockboard with fire retardant treated veneers

T. Laufenberg, N. Ayrilmis, R. White

Holz als Roh- und Werkstoff· Volume 64· Issue 2
Publisher page

Abstract

This study evaluated fire and bending properties of blockboards with various fire retardant treated veneers. Blockboards were manufactured using untreated fir strips and sandwiched between treated ekaba veneers at final assembly. The veneers were treated with either boric acid (BA), disodium octoborate tetrahydrate (DOT), alumina trihydrate (ATH), or a BA/DOT mixture. Modulus of rupture and modulus of elasticity tests were performed according to European Standard EN 310. Blockboards were also tested for fire resistance as indicated by a cone calorimeter. Treatments had little negative effect on flexural strength; flexural stiffness was significantly lower for the highest treatment levels. Treatments resulted in a significant reduction in predicted flame spread rate.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Wood Treatment and Properties · Flame retardant materials and properties · Fire dynamics and safety research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (18)

Show source-provided references
1. Akbulut TS, Kartal N, Green F (2004) Fiberboards treated with N’–N’ (1,8-naphthalyl) hydroxylamine (NHA-Na), borax, and boric acid. For Prod J 54(10):59–64
2. ASTM (1988) Standard test method for surface burning characteristics of building materials. Annual Book of Standards, E 84-87. American Society for Testing and Materials, Philadelphia, Pennsylvania
3. ASTM International (2001) Standard test method for surface burning characteristics of building materials. Annual Book of Standards, ASTM E 84-01. American Society for Testing and Materials International, West Conshohocken, Pennsylvania
4. ASTM International (2002) Standard test method for heat and visible smoke release rates for materials and products using an oxygen consumption calorimeter. Annual Book of Standards, ASTM E 1354-02. American Society for Testing and Materials International, West Conshohocken, Pennsylvania
5. Dietenberger MA, White RH (2001) Reaction-to-fire testing and modeling for wood products. In: Proceedings, 12th Annual BCC conference on flame retardancy, May 21–23, 2001, Stanford, Connecticut. Business Communications Co., Inc., Norwalk, Connecticut, pp 54–69
6. European Committee for Standardization (1993) Wood-based panels. Brussels, Belgium. EN 310: Determination of bending stength and modulus of elasticity. EN 323: Determination of density. EN 325: Determination of dimensions of test pieces
7. European Committee for Standardization (1994) Wood-based panels. Brussels, Belgium. EN 326-1: Sampling, cutting, and inspection. Part 1
8. Fogel JL, Lloyd JD (2002) Mold performance of some construction products with and without borates. For Prod J 52:38–43
9. Goker Y (1978) An investigation on technological properties of Turkish made plywoods, blockboards, particle boards, and development possibilities of this industries in Turkey. Istanbul University publication no. 2489, Forestry Faculty publication no. 267, Istanbul, Turkey
10. ISO (2002) Fire tests – Reaction to fire. Part 1: Rate of heat release from building products (cone calorimeter method), ISO 5660-1. International Organization for Standardization, Geneva, 39 pages
11. Maloney T (1996) The family of wood composite materials. For Prod J 46(2):19–26
12. Morrell JJ (2002) Wood-based composites: what have we learned? Int Biodeter Biodegr 49:253–25810.1016/S0964-8305(02)00052-5 ↗
13. NIST (2002) Performance standard for wood-based structural-use panels. Voluntary product standard. National Institute of Standards and Technology, Gaithersburg, Maryland
14. Tran HC, LeVan SL (1990) The role of boron in flame-retardant treatments. In: Hamel M (ed) Proceedings, 1st International conference on wood protection with diffusible preservatives, no. 47355, Nashville, Tennessee, November 28–30, 1990, pp 39–41
15. Vassiliou V (1996) Bending strength of thin 3-ply poplar plywood in relation to core veneer joints. Holz Roh- Werkst 54(5):36010.1007/s001070050201 ↗
16. White RH, Dietenberger MA (2004) Cone calorimeter evaluation of wood products. In: Proceedings, 15th Annual BCC conference on flame retardancy, Stanford, Connecticut, June 7–9, 2004. Business Communications Co., Inc., Norwalk, Connecticut, pp 331–342
17. White RH, Sweet MS (1992) Flame retardancy of wood: Present status, recent problems, and future fields. In: Lewin M (ed) Recent advances in flame retardancy of polymeric materials, Proceedings, 3rd Annual BCC conference on flame retardancy, Stanford, Connecticut, May 19–21, 1992, pp 250–257
18. Zanuttini R, Cremonini C (2002) Optimization of the test method for determining the bonding quality of core plywood (blockboard). Mater Struct 35(246):126–13210.1007/BF02482112 ↗