Probabilistic models for the withdrawal behavior of single self-tapping screws in the narrow face of cross laminated timber (CLT)
Source abstract
Abstract
Cross laminated timber (CLT) and self-tapping screws have strongly dominated the latest developments in timber engineering. Although knowledge of connection techniques in traditional light-frame structures can be applied to solid timber constructions with CLT, there are some product specifics requiring additional attention; for example in positioning of fasteners, differentiation in the side face and narrow face of the panels and the influence of potential gaps. The load–displacement behaviour of single, axially-loaded self-tapping screws positioned in the narrow face of CLT and failing in withdrawal was investigated. For the first time a multivariate probabilistic model was formulated together with models relating the parameters with the thread-fibre angle and the density. Different types and widths of gaps, initial slip and / or delayed stiffening as well as softening after exceeding of the maximum load can be considered. Beyond the scope of this contribution, the probabilistic model is seen as a worthwhile basis for investigations into the withdrawal behaviour of primary axially loaded, compact groups of screws positioned in timber products and subjected to withdrawal failure.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Wood Treatment and Properties · Mechanical Behavior of Composites · Structural Behavior of Reinforced Concrete
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (42)
Show source-provided references
1. Attiogbe E, Morris G (1991) Moment-rotation functions for steel connections. J Struct Eng 117(6):1703–171810.1061/(ASCE)0733-9445(1991)117:6(1703) ↗
2. Blaß HJ (1991) Traglastberechnungen von Nagelverbindungen [Characteristic strength of nailed joints]. Holz Roh-Werkst 49:91–98 (in German)10.1007/BF02614345 ↗
3. Blaß HJ, Uibel T (2007) Tragfähigkeit von stiftförmigen Verbindungsmitteln in Brettsperrholz [Load-bearing capacity of dowel-type fasteners in cross laminated timber]. Karlsruher Berichte zum Ingenieurholzbau 8, Lehrstuhl für Ingenieurholzbau und Baukonstruktionen, Universität Karlsruhe (TH), ISBN 9783866441293, pp 204 (in German)
4. Blaß HJ, Uibel T (2009) Bemessungsvorschläge für Verbindungsmittel in Brettsperrholz [Design proposals for fasteners in cross laminated timber]. Bauen mit Holz 111(2):46–53 (in German)
5. Blaß HJ, Bejtka I, Uibel T (2006) Tragfähigkeit von Verbindungen mit selbstbohrenden Holzschrauben mit Vollgewinde [Resistance of joints with self-tapping fully-threaded timber screws]. Karlsruher Berichte zum Ingenieurholzbau 4, Lehrstuhl für Ingenieurholzbau und Baukonstruktionen, Universität Karlsruhe (TH), ISBN 3866440340, pp 220 (in German)
6. Brandner R (2013a) Production and Technology of Cross Laminated Timber (CLT): A state-of-the-art Report. In: R Harries, A Ringhofer, G Schickhofer (ed.) Focus solid timber solutions—European conference on cross laminated timber (CLT), Graz University of Technology, COST Action FP1004, ISBN 1-85790-181-9
7. Brandner R (2013b) Stochastic system actions and effects in engineered timber products and structures. Verlag der Technischen Universität Graz, ISBN 978-3-85125-263-7
8. Brandner R, Gatternig W, Schickhofer G (2012) Determination of Shear Strength of Structural and Glued Laminated Timber. CIB-W18/45-12-2, Växjö, Sweden
9. Denzler JK, Glos P (2007) Determination of shear strength values according to EN 408. Mater Struct 40:79–8610.1617/s11527-006-9199-4 ↗
10. EN 13183 (2002) Moisture content of a piece of sawn timber—part 1: determination by oven dry method. European Committee for Standardization (CEN)
11. EN 1382 (1999) Timber structures—test methods—withdrawal capacity of timber fasteners. European Committee for Standardization (CEN)
12. EN 1995-1-1 (2008) +A1 Eurocode 5: design of timber structures—part 1–1: general—common rules and rules for buildings. European Committee for Standardization (CEN)
13. EN 26891 (1991) Timber structures—joints made with mechanical fasteners—general principles for the determination of strength and deformation characteristics. European Committee for Standardization (CEN)
14. EN 338 (2009) Structural timber—strength classes. European Committee for Standardization (CEN)
15. ETA-11/0190 (2011) European Technical Approval, Self-tapping screws for use in timber constructions. Adolf Würth GmbH and Co. KG
16. Flatscher G (2014) Beschreibung der Last-Verschiebungskurven von Verbindungen im Holzbau [Description of load-displacement curves of joints in timber engineering]. In: Kuhlmann U (ed) Doktorandenkolloquium “Holzbau Forschungs + Praxis”, pp 147–155, Stuttgart, Germany
17. Foschi RO (1974) Load-slip characteristics of nails. Wood Sci 7(1):69–76
18. Glos P (1978) Zur Bestimmung des Festigkeitsverhaltens von Brettschichtholz bei Druckbeanspruchung aus Werkstoff- und Einwirkungskenngrößen [For the determination of compression strength of glulam in relation to characteristics of material and exposure]. Berichte zur Zuverlässigkeit der Bauwerke 35, Sonderforschungsbereich 96, Laboratorium für den Konstruktiven Ingenieurbau (LKI), Technische Universität München (in German)
19. Gollwitzer S (1986) Zuverlässigkeit redundanter Tragsysteme bei geometrischer und stofflicher Nichtlinearität [Reliability of redundant structural systems given geometrical and material non-linearity]. Dissertation, Institut für Bauingenieurwesen III, Lehrstuhl für Massivbau, Technische Universität München, p 215 (in German)
20. Gollwitzer S, Rackwitz R (1990) On the reliability of Daniels systems. Struct Saf 7:229–24310.1016/0167-4730(90)90072-W ↗
21. Gordon JE (1988) The science of structures and materials. Scientific American Books Inc., Scientific American Library, ISBN 0-7167-5022-8
22. Grabner M (2013) Einflussparameter auf den Ausziehwiderstand selbstbohrender Holzschrauben in BSP-Schmalflächen [Influencing effects on the withdrawal resistance of self-tapping screws in the narrow faces of CLT]. Master thesis, Graz University of Technology (in German)
23. Hankinson RL (1921) Investigation of crushing strength of spruce at varying angles of grain. US Air Service Information Circular, Vol. 3, No. 259, Washington DC, US Air Service, Materials Section Paper No. 130
24. Hübner U (2013) Mechanische Kenngrößen von Buchen-, Eschen- und Robinienholz für lastabtragende Bauteile [Mechanical properties of beech, ash and black locust for load-bearing components]. Dissertation, Institute of Timber Engineering and Wood Technology, Graz University of Technology (in German)
25. ISO 3131 (1975) Wood—determination of density for physical and mechanical tests. International Organization for Standardization (ISO)
26. Jaspart JP (1991) Etude de la semi-rigidite des noeuds poutre-colonne et son influence sur la resistance et la stabilite des ossatures en acier [Study of the semi-rigidity of the beam-column nodes and its influence on the strength and stability of steel frames]. Dissertation, Faculte des Sciences Appliquees, Universite de Liege, pp 563 (in French)
27. Lane T (2014) The rise of cross laminated timber. Building.co.uk. http://www.building.co.uk/the-rise-of-cross-laminated-timber/5069291.article . Accessed 02 June 2016
28. McLain TE (1997) Design axial withdrawal strength from wood: I. Wood screws and lag screws. For Prod J 47(5):77–84
29. Newlin JA, Gahagan JM (1938) Lag-screw joints: their behaviour and Design. United States Department of Agriculture, Washington, DC. Technical Bullet No. 597
30. Pirnbacher G, Schickhofer G (2007) Schrauben im Vergleich – eine empirische Betrachtung [Comparison of screws – an empirical examination]. 6. Grazer Holzbau-Fachtagung (6.GraHFT’07) “Verbindungstechnik im Ingenieurholzbau”, Graz, Austria, F-1–22 (in German)
31. Pirnbacher G, Brandner R, Schickhofer G (2009) Base parameters of self-tapping screws. International Council for Research and Innovation in Building and Construction—Working Commission W18—Timber Structure, CIB-W18:42-7-1. Dübendorf, Switzerland
32. R Core Team (2013) R: a language and environment for statistical computing. R Foundation for Statistical Computing, Vienna. http://www.R-project.org/
33. Reichelt B (2012) Einfluss der Sperrwirkung auf den Ausziehwiderstand selbstbohrender Holzschrauben. Eine vergleichende Betrachtung zwischen BSP und BSH [Influence of the cross effect on the withdrawal resistance of self-tapping screws]. Master thesis, Graz University of Technology (in German)
34. Richard RM, Abbott BJ (1975) Versatile elastic-plastic stress-strain formula. J Engrg Mech Div, ASCE 101(4):511–51510.1061/JMCEA3.0002047 ↗
35. Ringhofer A, Brandner R, Grabner M, Schickhofer G (2014) Die Ausziehfestigkeit selbstbohrender Holzschrauben in geschichteten Holzprodukten [The withdrawal strength of self-tapping timber screws in laminated timber products]. Doktorandenkolloquium Holzbau—Forschung und Praxis, Stuttgart, Germany (in German)
36. Ringhofer A, Brandner R, Schickhofer G (2015) A Universal Approach for withdrawal properties of self-tapping screws in solid timber and laminated timber products. In: 2nd Meeting of the International Network on Timber Engineering Research (INTER), 48-7-1, Sibenik, Croatia
37. Schneider P (1999) Auszugsfestigkeit von EJOT-Rahmenschrauben [Withdrawal strength of EJOT screws]. Research Report, Eidgenössische Technische Hochschule (ETH) Zürich (in German)
38. Silva CV, Ringhofer A, Branco J, Schickhofer G (2014) The influence of moisture content and gaps on the withdrawal resistance of self tapping screws in CLT. CNME 2014—congresso nacional de mecânica experimental, Aveiro, Portugal
39. Soltis LA (1999) Wood handbook – Wood as an engineering material. Chapt. Fastenings, pp 7–1 to 7–29, Madison, WI: U.S.: United States Government Printing, 1999 (USDA Agricultural Handbook General technical report FPLGTR-113)
40. Statistisches Bundesamt (2016) Statistiken Zimmerei und Holzbau 2016 [Statistics of carpentry and timber engineering 2016]. Holzbau Deutschland—Bund Deutscher Zimmermeister im Zentralverband des Deutschen Baugewerbes, pp 4
41. Teischinger A, Stingl R, Zukal LM (2011) Holzbauanteil in Österreich: Statistische Erhebung von Hochbauvorhaben [Share of timber structures in Austria: statistical evaluation of building constructions]. Zuschnitt Attachment—Sonderthemen im Bereich Holz, Holzwerkstoff und Holzbau, proHolz Austria, ISBN 978-3-902320-84-1
42. Z-9.1-514 (2011) Allgemeine bauaufsichtliche Zulasssung, Würth ECOFAST-ASSY II und Würth ECOFAST-ASSY II Holzschrauben als Holzverbindungsmittel [General technical approval, Würth ECOFAST-ASSY II and Würth ECOFAST-ASSY II timber screws as timber fasteners]. Adolf Würth GmbH and Co. KG (in German)