Influence of insertion angle, diameter and thread on embedment properties of self-tapping screws
Source abstract
Abstract
In laterally loaded connections, inclined installation of self-tapping screws (STS) allows for axial load transfer and significantly higher connection capacity and stiffness. In such a configuration, both the withdrawal and embedment resistances of the screw contribute to the overall load-carrying capacity and stiffness. To account for the contribution of the embedment component, embedment strength of the screw appropriate for the insertion angle is required. In this study, embedment tests were conducted to determine the influence of STS diameter, insertion angle and fastener thread on embedment properties. Using specimens of Douglas fir, a total of 164 embedment tests with 40 different configurations were conducted and analyzed. Test results showed that embedment strength, stiffness, failure mode and yield load are strongly influenced by the insertion angle, whereas the influence of STS thread and diameter is less apparent. These results were compared with those from another study and the feasibility of a model accounting for inclined insertion angles was analyzed.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Load-Bearing Analysis · Mechanical stress and fatigue analysis · Structural Engineering and Vibration Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (25)
Show source-provided references
1. ASTM (2018) ASTM D5764-97a: standard test method for evaluating dowel-bearing strength of wood and wood-based products. ASTM International, West Conshohocken
2. Bejtka I (2005) Reinforcements of structural wood elements with fully threaded screws. PhD Dissertation, Karlsruhe University, Karlsruhe
3. CEN (2004) Eurocode 5: Design of timber structures. European Committee for Standardization, Brussels
4. Chui YH, Smith I, Chen Z (2006) Influence of fastener size on lateral strength of steel-to-wood screw joints. For Prod J 56:49–54
5. Clouston P (1995) The Tsai-Wu strength theory for Douglas-Fir Laminated Veneer. PhD Dissertation, University of British Columbia, Vancouver
6. CSA (2019) CSA O86-19 Engineering Design in Wood. Canadian Standards Association, Toronto
7. Dietsch P, Brandner R (2015) Self-tapping screws and threaded rods as reinforcement structural timber elements–a state-of-the-art report. Constr Build Mater 97:78–79. https://doi.org/10.1016/j.conbuildmat.2015.04.02810.1016/j.conbuildmat.2015.04.028 ↗
8. Franke S, Magnière N (2014) Discussion of testing and evaluation methods for the embedment behaviour of connections. Proceedings of International Network on Timber Engineering Research, Bath
9. Goodman J, Bodig J (1971) Orthotropic beams under normal and shear loading. J Eng Mech 4:83–94
10. Johansen KW (1949) Theory of timber connections. International Association for Bridge and Structural Engineering 9:249–262
11. Kennedy S, Salenikovich A, Muñoz W, Mohammad M, Sattler D (2014) Design equations for embedment strength of wood for threaded fasteners in the Canadian timber design code. Proceedings of World Conference on Timber Engineering, Quebec City
12. Michael A (2008) Connections in timber structures. Frederick Institute of Technology, Nicosia
13. Mirdad MAH, Chui YH (2019) Load-slip performance of mass timber panel-concrete (MTPC) composite connection with Self-tapping screws and insulation layer. Constr Build Mater 213:698–708. https://doi.org/10.1016/j.conbuildmat.2019.04.11710.1016/j.conbuildmat.2019.04.117 ↗
14. Mirdad MAH, Chui YH (2020) Stiffness prediction of mass timber panel-concrete (MTPC) composite connection with inclined screws and a gap. Eng Struct. https://doi.org/10.1016/j.engstruct.2020.11021510.1016/j.engstruct.2020.110215 ↗
15. Pirnbacher, G, Brandner R, Schickhofer G (2009) Base Parameters of Self-Tapping Screws. Proceedings of CIB W18-Timber Structures, Duebendorf
16. Reynolds T, Harris R, Chang WS (2013) An analytical model for the dynamic stiffness of a dowel in timber under cyclic load. Eur J Wood Prod 71:609–622. https://doi.org/10.1007/s00107-013-0716-110.1007/s00107-013-0716-1 ↗
17. Ringhofer A, Brandner R, Schickhofer G (2015) Withdrawal resistance of self-tapping screws in unidirectional and orthogonal layered timber products. Mater Struct 48:1435–1447. https://doi.org/10.1617/s11527-013-0244-910.1617/s11527-013-0244-9 ↗
18. Ringhofer A, Augustin M, Schickhofer G (2019) Basic steel properties of self-tapping screws exposed to cyclic axial loading. Constr Build Mater 211:207–216. https://doi.org/10.1016/j.conbuildmat.2019.03.20010.1016/j.conbuildmat.2019.03.200 ↗
19. Risbrudt C, Ritter M, Wegner T (2010) Wood Handbook - Wood as an engineering material (Gen Tech Rep FPL-GTR-190). US Dept. of Agriculture, Forest Service, Forest Products Laboratory, Madison
20. Rothoblaas (2019) VGS. https://www.rothoblaas.com/products/fastening/screws/screws-structures/vgs#specs. Accessed Feb 20 2020
21. Rowse RC (1923) The strength of Douglas-Fir in compression at various angles to the grain. Washington University, St. Louis
22. Sawata K, Yasumura M (2002) Determination of embedding strength of wood for dowel-type fasteners. Jpn Wood Res Soc 48:138–146. https://doi.org/10.1007/BF0076729110.1007/BF00767291 ↗
23. MTC Solutions (2019) ASSY VG CSK. https://mtcsolutions.com/product/assy-vg-csk-counter-sunk-head/. Accessed Feb 20 2020
24. Whale LRJ, Smith I, Larsen HJ (1987) Design of nailed and bolted joints. Proposal for the revision of existing formulae in draft Eurocode 5 and the CIB code. Proceedings of CIB-W18A meeting, Dublin
25. Wilkinson TL (1991) Dowel bearing strength. USDA Forest Service, Forest Products Laboratory, Madison