journal article·2015-07Open access

Spreading of transverse compressive stresses in glued laminated timber

Damien Lathuilliere, Octavian Pop, Laurent Bléron, Frédéric Dubois, Fazia Fouchal, Jean-François Bocquet

Abstract

This paper presents a new approach for understanding localized compressive behavior perpendicular to the grain based on beams subjected to three-point bending. It was intended to take into account the coupling between compressive stresses perpendicular to the grain due to support reactions and shear stresses. To validate this, model, results of compression tests have been examined. The digital image correlation (DIC) method has been applied in order to analyze the deformation fields in support areas. The tests allow confirming the presence of spreading effect in the vicinity of support areas according to the DIC method. An analytical formulation has therefore been proposed to quantify distribution versus increasing compressive strength perpendicular to the grain, including shear effects. A scale effect and support conditions have also been highlighted using three different geometries and two types of tests.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Wood Treatment and Properties · Mechanical Behavior of Composites · Optical measurement and interference techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (16)

Show source-provided references
1. Augustin M, Ruli A, Brandner R, Schickhofer G (2006) Behavior of glulam in compression perpendicular to grain in different strength grades and load configurations. In: CIB-W18, paper 39-12-6, Florence, Italy
2. Blass H-J, Bejtka I (2004) Reinforcements perpendicular to the grain using self-tapping screws. In: WCTE, vol 1, Helsinki, Finland. http://www.rz.uni-karlsruhe.de/~gc20/IHB/PUBLIC/37.pdf
3. Blass H-J, Görlacher R (2004) Compression perpendicular to the grain. In: WCTE, pp 14–17, Helsinki, Finland. http://www.rz.uni-karlsruhe.de/~gc20/IHB/PUBLIC/35.pdf
4. Bléron L, Cabaton L, Sauvignet E (2009) Compression perpendicular at the grain, mechanical tests—modelling. In: CFM, Bordeaux, France
5. Ed D, Hasselqvist F (2011) Timber compression strength perpendicular to the grain. Lund Institute of Technology, Lund
6. Kollmann F (1955) Technology of wood and wood based materials. Springer, Berlin (in German)
7. Leijten AJM, Jorissen AJM, de Leijer BJC (2012) The Local bearing capacity perpendicular to grain of structural timber elements. Constr Build Mater 27(1):54–5910.1016/j.conbuildmat.2011.07.022 ↗
8. Madsen B (1992) Structural behavior of timber. Timber Engineering, North Vancouver
9. Madsen B (2000) Behavior of timber connections. Timber Engineering, Vancouver
10. Mähr M (2002) Reinforcement of compression perpendicular to the grain with self-tapping screws. Fachhochschule Liechtenstein, Vaduz (in German)
11. Nilsson K (2002) Reinforcement of wood by screws loaded perpendicular to the grain. In: Fiberriktningen. Rapport TVBK-5112. Lunds Tekniska Högskola, Lund (in Swedish)
12. Reichegger M (2004) Compression perpendicular to the grain in structural elements according to the new standard proposal. Universitá degli Studi di Trento, Trento (in Italian)
13. Riberholt H (2000) Compression perpendicular to the grain of wood. COWI-report 42239-1
14. Sutton MA, Wolters W, Peters WH, Ranson WF, McNeil SR (1983) Determination of displacements using an improved digital correlation method. Image Vis Comput 1(3):133–13910.1016/0262-8856(83)90064-1 ↗
15. Sutton MA, Cheng MQ, Peters WH, Chao YJ, McNeil SR (1986) Application of an optimized digital correlation method to planar deformation analysis. Image Vis Comput 4(3):143–15110.1016/0262-8856(86)90057-0 ↗
16. Van der Put TACM (2008) Derivation of the bearing strength perpendicular to the grain of locally loaded timber blocks. Delft Wood Sci Found 66(6):409–417