Preliminary comparative study on the behaviour of highly-loaded glue laminated timber and wood-CFRP composite beams exposed to local fire
Source abstract
Abstract
Abstract The paper presents a complex solution for testing loaded structural-sized glue laminated timber and innovative wood-carbon fibre reinforced polymers (CFRP) composite beams exposed to local fire. It shows the entire procedure from predicting a static behaviour and a combustion time (from reaching 300 °C temperature of the element up to its fracture) of the tested elements, designing and building an experimental stand, through conducting preliminary tests and discussing the results. The research included combustion of three glue laminated timber (BSH) and three wood-CFRP composite (BSH-CFRP) structural-sized beams in the most loaded section (region of highest bending moment) under three-point bending. A furnace was set under the centre of the beam on one-third of its span. The dimensions of the basket are based on physical properties of firewood providing proper burning conditions of the elements. The self-designed and self-constructed experimental stand enabled applying high load and provided a stable loading during local fire exposure. The preliminary tests showed that using CFRP tapes inside the section may both increase or decrease fire resistance of wooden members depending on the width of wood material covering CFRP tape. CFRP tapes provide a different nature of beam failure, which is changing from sudden fracture (BSH) to plastic flow of the material (BSH-CFRP).
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Structural Response to Dynamic Loads · Structural Behavior of Reinforced Concrete · Flame retardant materials and properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (48)
Show source-provided references
1. Andor K, Lengyel A, Polgár R et al (2015) Experimental and statistical analysis of spruce timber beams reinforced with CFRP fabric. Constr Build Mater 99:200–207. https://doi.org/10.1016/j.conbuildmat.2015.09.02610.1016/j.conbuildmat.2015.09.026 ↗
2. Bergner K, Tosch M, Zauer M et al (2018) Process development for the manufacture of fiber reinforced wood composites (FRWC). Constr Build Mater 180:275–284. https://doi.org/10.1016/j.conbuildmat.2018.04.00110.1016/j.conbuildmat.2018.04.001 ↗
3. Brunetti M, Christovasilis IP, Micheloni M et al (2019) Production feasibility and performance of carbon fibre reinforced glulam beams manufactured with polyurethane adhesive. Compos Part B Eng 156:212–219. https://doi.org/10.1016/j.compositesb.2018.08.07510.1016/j.compositesb.2018.08.075 ↗
4. Chen C, Yang J, Chen J et al (2017) Fire resistance performance of glulam beam. J Cent South Univ 24:929–936. https://doi.org/10.1007/s11771-017-3495-810.1007/s11771-017-3495-8 ↗
5. Chorlton B, Gales J (2020) Mechanical performance of laminated veneer lumber and glulam beams after short-term incident heat exposure. Constr Build Mater 263:120129. https://doi.org/10.1016/j.conbuildmat.2020.12012910.1016/j.conbuildmat.2020.120129 ↗
6. Cichy W, Witczak M, Walkowiak M (2017) Fuel properties of woody biomass from pruning operations in fruit orchards. BioResources 12:6458–6470. https://doi.org/10.15376/biores.12.3.6458-647010.15376/biores.12.3.6458-6470 ↗
7. de la Rosa GP, Cobo Escamilla A, González García MN (2016) Analysis of the flexural stiffness of timber beams reinforced with carbon and basalt composite materials. Compos Part B Eng 86:152–159. https://doi.org/10.1016/j.compositesb.2015.10.00310.1016/j.compositesb.2015.10.003 ↗
8. Fahrni R, Klippel M, Just A et al (2019) Fire tests on glued-laminated timber beams with specific local material properties. Fire Saf J 107:161–169. https://doi.org/10.1016/j.firesaf.2017.11.00310.1016/j.firesaf.2017.11.003 ↗
9. Firmanti A, Subiyanto B, Takino S, Kawai S (2004) The critical stress in various stress levels of bending member on fire exposure for mechanical graded lumber. J Wood Sci 50:385–390. https://doi.org/10.1007/s10086-003-0589-810.1007/s10086-003-0589-8 ↗
10. Firmanti A, Subiyanto B, Kawai S (2006) Evaluation of the fire endurance of mechanically graded timber in bending. J Wood Sci 52:25–32. https://doi.org/10.1007/s10086-005-0721-z10.1007/s10086-005-0721-z ↗
11. Frangi A, Bertocchi M, Clauß S, Niemz P (2012) Mechanical behaviour of finger joints at elevated temperatures. Wood Sci Technol 46:793–812. https://doi.org/10.1007/s00226-011-0444-910.1007/s00226-011-0444-9 ↗
12. Franke S, Franke B, Harte AM (2015) Failure modes and reinforcement techniques for timber beams – state of the art. Constr Build Mater 97:2–13. https://doi.org/10.1016/j.conbuildmat.2015.06.02110.1016/j.conbuildmat.2015.06.021 ↗
13. Glišović I, Stevanović B, Todorović M (2016) Flexural reinforcement of glulam beams with CFRP plates. Mater Struct 49:2841–2855. https://doi.org/10.1617/s11527-015-0690-710.1617/s11527-015-0690-7 ↗
14. Halicka A, Ślósarz S (2021) Strengthening of timber beams with pretensioned CFRP strips. Structures 34:2912–2921. https://doi.org/10.1016/j.istruc.2021.09.05510.1016/j.istruc.2021.09.055 ↗
15. Halicka A, Ślósarz S (2022) Analysis of behavior and failure modes of timber beams prestressed with CFRP strips. Compos Struct 301:116171. https://doi.org/10.1016/j.compstruct.2022.11617110.1016/j.compstruct.2022.116171 ↗
16. He M, Wang Y, Li Z et al (2022) An experimental and analytical study on the bending performance of CFRP-reinforced glulam beams. Front Mater 8:1–14. https://doi.org/10.3389/fmats.2021.80224910.3389/fmats.2021.802249 ↗
17. Jankowski LJ, Jasieńko J, Nowak TP (2010) Experimental assessment of CFRP reinforced wooden beams by 4-point bending tests and photoelastic coating technique. Mater Struct 43:141–150. https://doi.org/10.1617/s11527-009-9476-010.1617/s11527-009-9476-0 ↗
18. Kawecki B (2021a) Selection of the parameters for numerical models of full girders made of wood-polymer composites reinforced with fibres. Wydawnictwo Politechniki Lubelskiej, Lublin (in Polish)
19. Kawecki B (2021b) Guidelines for FEM modelling of wood-CFRP beams using ABAQUS. Arch Civil Eng 67:175–191. https://doi.org/10.24425/ace.2021.13849310.24425/ace.2021.138493 ↗
20. Kawecki B, Podgórski J (2020a) 3D ABAQUS simulation of bent softwood elements. Arch Civ Eng 66:323–337. https://doi.org/10.24425/ace.2020.13440010.24425/ace.2020.134400 ↗
21. Kawecki B, Podgórski J (2020b) The effect of glue cohesive stiffness on the elastic performance of bent wood–CFRP beams. Materials (basel) 13:1–23. https://doi.org/10.3390/ma1322507510.3390/ma13225075 ↗
22. Krajnc N (2015) Wood fuels handbook. Food and Agriculture Organization of the United Nations, Pristina
23. Lineham SA, Thomson D, Bartlett AI et al (2016) Structural response of fire-exposed cross-laminated timber beams under sustained loads. Fire Saf J 85:23–34. https://doi.org/10.1016/j.firesaf.2016.08.00210.1016/j.firesaf.2016.08.002 ↗
24. Martin ZA, Tingley DA (2000) Fire resistance of FRP reinforced glulam beams. In: Proceedings of World Conference on Timber Engineering. July 31–August 3, Whistler Resort, Canada
25. Morales-Conde MJ, Rodríguez-Liñán C, Rubio-de Hita P (2015) Bending and shear reinforcements for timber beams using GFRP plates. Constr Build Mater 96:461–472. https://doi.org/10.1016/j.conbuildmat.2015.07.07910.1016/j.conbuildmat.2015.07.079 ↗
26. Nadir Y, Nagarajan P, Ameen M, Arif MM (2016) Flexural stiffness and strength enhancement of horizontally glued laminated wood beams with GFRP and CFRP composite sheets. Constr Build Mater 112:547–555. https://doi.org/10.1016/j.conbuildmat.2016.02.13310.1016/j.conbuildmat.2016.02.133 ↗
27. Nowak TP, Jasieńko J, Czepiżak D (2013) Experimental tests and numerical analysis of historic bent timber elements reinforced with CFRP strips. Constr Build Mater 40:197–206. https://doi.org/10.1016/j.conbuildmat.2012.09.10610.1016/j.conbuildmat.2012.09.106 ↗
28. Ogawa H (2000) Architectural application of carbon fibers development of new carbon fiber reinforced glulam. Carbon N Y 38:211–226. https://doi.org/10.1016/S0008-6223(99)00146-310.1016/S0008-6223(99)00146-3 ↗
29. PN-EN 14080:2013 (2013) Timber structures. Glued laminated timber and glued solid timber. Requirements. Polski Komitet Normalizacyjny, Warsaw
30. PN-EN 1995-1-2:2008 (2008) Eurocode 5: design of timber structures—part 1–2: general structural fire design. Polski Komitet Normalizacyjny, Warsaw
31. PN-EN 1363-1:2020 (2020) Fire resistance tests—part 1: general requirements. Polski Komitet Normalizacyjny, Warsaw
32. Qin R, Zhou A, Chow CL, Lau D (2021) Structural performance and charring of loaded wood under fire. Eng Struct 228:111491. https://doi.org/10.1016/j.engstruct.2020.11149110.1016/j.engstruct.2020.111491 ↗
33. Quiquero H, Chorlton B, Gales J (2018) Performance of adhesives in glulam after short term fire exposure. Int J High-Rise Build 7:299–311. https://doi.org/10.21022/IJHRB.2018.7.4.29910.21022/IJHRB.2018.7.4.299 ↗
34. Raftery GM, Harte AM (2011) Low-grade glued laminated timber reinforced with FRP plate. Compos Part B Eng 42:724–735. https://doi.org/10.1016/j.compositesb.2011.01.02910.1016/j.compositesb.2011.01.029 ↗
35. Raftery GM, Rodd PD (2015) FRP reinforcement of low-grade glulam timber bonded with wood adhesive. Constr Build Mater 91:116–125. https://doi.org/10.1016/j.conbuildmat.2015.05.02610.1016/j.conbuildmat.2015.05.026 ↗
36. Raftery GM, Whelan C (2014) Low-grade glued laminated timber beams reinforced using improved arrangements of bonded-in GFRP rods. Constr Build Mater 52:209–220. https://doi.org/10.1016/j.conbuildmat.2013.11.04410.1016/j.conbuildmat.2013.11.044 ↗
37. Rescalvo F, Valverde-Palacios I, Suarez E, Gallego A (2017) Experimental comparison of different carbon fiber composites in reinforcement layouts for wooden beams of historical buildings. Materials (Basel) 10:1113. https://doi.org/10.3390/ma1010111310.3390/ma10101113 ↗
38. Ryan JV, Robertson AF (1959) Proposed criteria for defining load failure of beams, floors, and roof constructions during fire tests. J Res Natl Bur Stand Sect C Eng Instrum 63C:121–12410.6028/jres.063C.017 ↗
39. S&P C-LAMINATE Technical Information (2023). https://www.sp-reinforcement.pl/sites/default/files/field_product_col_doc_file/c-laminates_polska_ver012019-low.pdf
40. Schmid J, König J, Köhler J (2010) Fire-exposed cross-laminated timber - Modelling and tests. World Conf Timber Eng 4:3268–3276
41. Schober K-U, Harte AM, Kliger R et al (2015) FRP reinforcement of timber structures. Constr Build Mater 97:106–118. https://doi.org/10.1016/j.conbuildmat.2015.06.02010.1016/j.conbuildmat.2015.06.020 ↗
42. Subhani M, Globa A, Al-Ameri R, Moloney J (2017) Flexural strengthening of LVL beam using CFRP. Constr Build Mater 150:480–489. https://doi.org/10.1016/j.conbuildmat.2017.06.02710.1016/j.conbuildmat.2017.06.027 ↗
43. Vahedian A, Shrestha R, Crews K (2019) Experimental and analytical investigation on CFRP strengthened glulam laminated timber beams: full-scale experiments. Compos Part B 164:377–389. https://doi.org/10.1016/j.compositesb.2018.12.00710.1016/j.compositesb.2018.12.007 ↗
44. Wang Y, Zhang J, Mei F et al (2020) Experimental and numerical analysis on fire behaviour of loaded cross-laminated timber panels. Adv Struct Eng 23:22–36. https://doi.org/10.1177/136943321986445910.1177/1369433219864459 ↗
45. Yang TH, Wang SY, Tsai MJ et al (2009) Effect of fire exposure on the mechanical properties of glued laminated timber. Mater Des 30:698–703. https://doi.org/10.1016/j.matdes.2008.05.02210.1016/j.matdes.2008.05.022 ↗
46. Yang H, Ju D, Liu W, Lu W (2016a) Prestressed glulam beams reinforced with CFRP bars. Constr Build Mater 109:73–83. https://doi.org/10.1016/j.conbuildmat.2016.02.00810.1016/j.conbuildmat.2016.02.008 ↗
47. Yang H, Liu W, Lu W et al (2016b) Flexural behavior of FRP and steel reinforced glulam beams: Experimental and theoretical evaluation. Constr Build Mater 106:550–563. https://doi.org/10.1016/j.conbuildmat.2015.12.13510.1016/j.conbuildmat.2015.12.135 ↗
48. Zhang C, Chun Q, Wang H et al (2022) Experimental study on the flexural behaviour of timber beams strengthened with high ductility and low cost hybrid fibre sheets. Constr Build Mater 322:126514. https://doi.org/10.1016/j.conbuildmat.2022.12651410.1016/j.conbuildmat.2022.126514 ↗