Structural performance of novel precast column-foundation connections: an experimental investigation
Source abstract
Abstract
ABSTRACT Most projects in India utilized cast-in-situ concrete, despite the widespread use of precast concrete structural technologies globally. The swift increase in India’s population and the scarcity of space led to a significant demand for multistory residential buildings. As a form of natural disaster, Earthquakes inflicted considerable damage on infrastructure and resulted in loss of life. It was determined that the inadequate performance of the connectors was responsible for the failure of the precast constructions. The connections were the most vulnerable aspect of the precast concrete structure. The present study investigated the behavior of precast column-footing connections subjected to monotonic lateral loading. Two half-scale column-footing connection specimens-one conventional and the other precast-were prepared and tested under monotonic lateral loading. These elements were tested under lateral load. The precast column-footing connection was connected using a half-grouted sleeve. The study’s main aim was to investigate the load-carrying capacity, mode of failure, crack pattern, stiffness, energy absorption and ductility of the column-footing connection elements. The half-grouted sleeve precast column-footing connection element performs better than the conventional concrete column- footing connection. The half-grouted sleeve column-footing connection exhibited higher performance than the conventional connection, with increases in load-carrying capacity (8.47%), ductility (27.08%), energy absorption (30.96%), stiffness (2.1%), and energy dissipation (23.28%). The research is recommended for implementation in practical applications.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Structural Load-Bearing Analysis · Seismic Performance and Analysis · Structural Behavior of Reinforced Concrete
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Kumaraguru College of Technology, India
K. Ramakrishnan College of Technology, India
References (35)
Show source-provided references
1. “Tensile behavior of half grouted sleeve connection at elevated temperatures”10.1016/j.conbuildmat.2018.05.027 ↗
2. “Seismic performance of precast column connected with grouted sleeve connectors”10.1016/j.jobe.2020.101410 ↗
3. “Experimental investigation of mechanical properties of steel half-grouted sleeve splice with rebar bonding defects”10.1016/j.jobe.2022.104113 ↗
4. “Experimental investigation on the connection performance of defect detectable and repairable half-grouted sleeve under cyclic loads”10.1016/j.conbuildmat.2022.126593 ↗
5. “Seismic behavior of RC beam-column joints with 600 MPa high-strength steel bars”10.3390/app10134684 ↗
6. “Experimental study of a new beam-to-column connection for precast concrete frames under reversal cyclic loading”10.1177/1369433216630122 ↗
7. “Grouted sleeve connection for precast concrete members”
8. “Effect of pozzolanic materials on mechanical properties and aging of glass fiber reinforced concrete”10.1016/j.conbuildmat.2019.07.128 ↗
9. “Experimental study on post-fire performance of half-grouted sleeve connection with construction defect”10.1016/j.conbuildmat.2020.118165 ↗
10. “Experimental bond behavior of deformed rebars in half-grouted sleeve connections with insufficient grouting defects”
11. “Experimental investigation of mechanical behaviour of rebar in steel half-grouted sleeve connections with defects in water/binder ratio”10.1016/j.istruc.2020.04.051 ↗
12. “Seismic performance of reinforced concrete beam-column joint: a review”
13. “Experimental and numerical investigation of a proposed monolithic-like precast concrete column–foundation connection”10.1016/j.engstruct.2021.113090 ↗
14. “Behaviour of precast column foundation connection under reverse cyclic loading”10.1155/2021/6677007 ↗
15. “Experimental investigation of a new precast column-foundation connection under cyclic loading”10.1016/j.jobe.2022.104245 ↗
16. “Cyclic response of column to foundation connections of reinforced concrete precast structures: Numerical and experimental comparisons”10.1016/j.engstruct.2021.113214 ↗
17. “An innovative connection proposal for the precast prestressed column-foundation connection”10.1617/s11527-023-02218-5 ↗
18. “Cyclic test on a precast reinforced concrete column-to-foundation grouted duct connection”10.1007/s10518-019-00766-2 ↗
19. “Mechanical properties of grouted splice sleeve connectors inside prefabricated concrete structures in cold regions”10.1016/j.istruc.2025.109737 ↗
20. “Seismic performance evaluation of precast bridge piers under combined freeze-thaw, chloride corrosion, and wetting-drying cycling effects”10.1016/j.istruc.2025.109899 ↗
21. “Experimental study on the seismic performance of precast segmental unbonded post-tensioned frame piers”10.1016/j.soildyn.2023.108143 ↗
22. 2019
23. 2008
24. “Assessment of axial load carrying capacity of fully encased composite columns: comparative study with different codes”10.1590/1517-7076-rmat-2024-0303 ↗
25. “Behaviour of high strength concrete encased steel composite short columns subjected to axial load”
26. “Analytical investigations of reinforced concrete beam–column joints constructed using high-strength materials”10.1080/13632469.2018.1453403 ↗
27. “Exterior RC wide beam-column connections: effect of beam width ratio on seismic behaviour”10.1016/j.engstruct.2017.05.044 ↗
28. “Experimental study on seismic behavior of precast concrete column with grouted sleeve connections considering ratios of longitudinal reinforcement and stirrups”10.1007/s10518-018-0414-9 ↗
29. “Experimental investigation on the connection performance of defect detectable and repairable half-grouted sleeve under cyclic loads”10.1016/j.conbuildmat.2022.126593 ↗
30. “Mechanical behaviour of grouted sleeve splice under uniaxial tensile loading”10.1016/j.engstruct.2019.02.033 ↗
31. “Experimental study on the fully encased composite short columns made with high strength fibre reinforced concrete”10.1007/s42107-023-00975-w ↗
32. “Performance of high strength concrete encased steel composite columns”
33. “Behavior and design of precast column/base pocket connections with smooth surface interface”
34. “Assessment of axial load carrying capacity of fully encased composite columns: comparative study with different codes”10.1590/1517-7076-rmat-2024-0303 ↗
35. “Experimental investigation of mechanical properties of steel half-grouted sleeve splice with rebar bonding defects”10.1016/j.jobe.2022.104113 ↗