An anisotropic nonlinear elasticity model for tearing of fibrous soft biomaterials
Source abstract
Abstract
The application of nonlinear elasticity concepts to the mechanical modeling of soft biomaterials is currently the subject of intense investigation. For fibrous soft biomaterials, some specific strain-energy density models for anisotropic hyperelastic materials have been proposed in the literature that are particularly useful as they reflect the typical J-shaped stress–stretch stiffening response due to collagen fibers that is observed experimentally. These models have the feature of incorporating the increased stiffness of the collagen fibers with deformation and involve a maximum fiber stretch (or locking stretch). Here we apply such models to the analysis of the fracture or tearing of fibrous soft biomaterials. Attention is focused on a particular fracture test namely the trousers test where two legs of a cut specimen are pulled horizontally apart out of the plane of the test piece. It is shown that, in general, the location of the cut in the specimen plays a key role in the fracture analysis, and that the effect of the cut position depends crucially on the degree of strain–stiffening. This dependence is characterized explicitly for the specific strain–stiffening constitutive models considered. The effects of anisotropy and strain–stiffening on the fracture toughness (resistance to tearing) are also examined.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Elasticity and Material Modeling · Automotive and Human Injury Biomechanics · Cellular and Composite Structures
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Engineering and Applied Science, University of Virginia, Charlottesville, Virginia, USA
Space Exploration Technologies, Hawthorne, California, USA
References (38)
Show source-provided references
1. 10.1007/978-0-387-21576-110.1007/978-0-387-21576-1 ↗
2. Holzapfel GA · 2005 · 607
3. 10.5254/1.353835710.5254/1.3538357 ↗
4. 10.1177/10812802847710.1177/108128028477 ↗
5. 10.1007/s10237-002-0022-z10.1007/s10237-002-0022-z ↗
6. 10.5254/1.354792410.5254/1.3547924 ↗
7. 10.1016/j.jmbbm.2011.09.01810.1016/j.jmbbm.2011.09.018 ↗
8. 10.5254/1.353868810.5254/1.3538688 ↗
9. 10.5254/1.354776110.5254/1.3547761 ↗
10. 10.1007/BF0054073110.1007/BF00540731 ↗
11. 10.1016/0021-9290(83)90058-110.1016/0021-9290(83)90058-1 ↗
12. 10.1088/0022-3727/22/6/02610.1088/0022-3727/22/6/026 ↗
13. 10.1115/1.279604210.1115/1.2796042 ↗
14. 10.1016/j.jbiomech.2010.02.02910.1016/j.jbiomech.2010.02.029 ↗
15. Atkins AG · 1985
16. 10.1088/0022-3727/22/1/00710.1088/0022-3727/22/1/007 ↗
17. 10.1016/0013-7944(74)90012-510.1016/0013-7944(74)90012-5 ↗
18. 10.1002/pol.1953.12010030310.1002/pol.1953.120100303 ↗
19. 10.1016/j.jmps.2004.09.00110.1016/j.jmps.2004.09.001 ↗
20. 10.1016/j.ijsolstr.2011.09.01810.1016/j.ijsolstr.2011.09.018 ↗
21. Holzapfel GA · 2000
22. 10.1017/CBO9780511526466.00210.1017/CBO9780511526466.002 ↗
23. 10.1016/j.jmps.2005.04.00410.1016/j.jmps.2005.04.004 ↗
24. 10.1007/BF0004263410.1007/BF00042634 ↗
25. 10.1023/A:100741032131910.1023/A:1007410321319 ↗
26. 10.1023/A:101162550975410.1023/A:1011625509754 ↗
27. 10.1016/j.ijnonlinmec.2004.05.00310.1016/j.ijnonlinmec.2004.05.003 ↗
28. 10.1016/j.ijnonlinmec.2006.02.00110.1016/j.ijnonlinmec.2006.02.001 ↗
29. 10.1098/rspa.2010.028810.1098/rspa.2010.0288 ↗
30. 10.1115/1.297986910.1115/1.2979869 ↗
31. 10.1142/545210.1142/5452 ↗
32. 10.1016/j.ultrasmedbio.2007.04.02010.1016/j.ultrasmedbio.2007.04.020 ↗
33. 10.1007/s10237-006-0064-810.1007/s10237-006-0064-8 ↗
34. 10.1016/j.jtbi.2008.10.01810.1016/j.jtbi.2008.10.018 ↗
35. 10.1115/1.274443510.1115/1.2744435 ↗
36. 10.1007/s10659-010-9282-510.1007/s10659-010-9282-5 ↗
37. 10.1016/j.ijnonlinmec.2011.03.00310.1016/j.ijnonlinmec.2011.03.003 ↗
38. Busfield JJC · Prog Rubber Technol · 1996 · 12 · 19110.1177/147776069601200303 ↗