journal article·1999-09

Digital volume correlation: Three-dimensional strain mapping using X-ray tomography

B. K. Bay, T. S. Smith, D. P. Fyhrie, M. Saad

Experimental Mechanics· Volume 39· Issue 3
Publisher page

Abstract

No abstract is available for this record. The assistant can identify its topic from the title, but cannot infer the study’s results.

Source: Not provided · Quality: missing

Research context

OpenAlex topics: Optical measurement and interference techniques · Medical Imaging Techniques and Applications · Advanced X-ray Imaging Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (38)

Show source-provided references
1. Bruck, H.A., McNeill, S.R., Sutton, M.A., andPeters, W.H., III, “Digital Image Correlation Using Newton-Raphson Method of Partial Differential Correction,” EXPERIMENTAL MECHANICS,29,261–267 (1989).10.1007/BF02321405 ↗
2. Chu, T.C., Ranson, W.F., Sutton, M.A., andPeters, W.H., “Applications of Digital-image-correlation Techniques to Experimental Mechanics,” EXPERIMENTAL MECHANICS,25,232–244 (1985).10.1007/BF02325092 ↗
3. Kahn-Jetter, Z.L., Jha, N.K., andBhatia, H., “Optimal Image Correlation in Experimental Mechanics,”Opt. Eng.,33,1099–1105 (1994).10.1117/12.166931 ↗
4. Sutton, M.A., Wolters, W.J., Peters, W.H., Ranson, W.F., andMcNeill, S.R., “Determination of Displacements Using an Improved Digital Correlation Method,”Image Vis. Computing,1,133–139 (1983).10.1016/0262-8856(83)90064-1 ↗
5. Sutton, M.A., Cheng, M., Peters, W.H., Chao, Y.J., andMcNeill, S.R., “Application of an Optimized Digital Correlation Method to Planar Deformation Analysis,”Image Vis. Computing,4,143–150 (1986).10.1016/0262-8856(86)90057-0 ↗
6. Boegli, V. andKern, D.P., “Automatic Mark Detection in Electron Beam Nanolithography Using Digital Image Processing and Correlation,”J. Vacuum Sci. Tech.,8,1994–2001 (1990).10.1116/1.584890 ↗
7. Lyons, J.S., Liu, J., andSutton, M.A., “High-temperature Deformation Measurements Using Digital-image Correlation,” EXPERIMENTAL MECHANICS,36,64–70 (1996).10.1007/BF02328699 ↗
8. McNeill, S.R., Peters, W.H., andSutton, M.A., “Estimation of Stress Intensity Factor by Digital Image Correlation,”Eng. Fract. Mech.,28,101–112 (1987).10.1016/0013-7944(87)90124-X ↗
9. Manduchi, R. and Mian, G.A., “Accuracy Analysis for Correlation-based Image Registration Algorithms,” IEEE International Symposium on Circuits and Systems, Chicago (1993).
10. Sutton, M.A., McNeill, S.R., Jang, J., andBabai, M., “Effects of Subpixel Image Restoration on Digital Correlation Error Estimates,”Opt. Eng.,27,870–877 (1988).10.1117/12.7976778 ↗
11. Tolat, A.R., McNeill, S.R., and Sutton, M.A., “Effects of Contrast and Brightness on Subpxel Image Correlation,” Proceedings of the Twenty-Third Southeastern Symposium on System Theory, Columbia, South Carolina (1991).10.1109/SSST.1991.138639 ↗
12. Russell, S.S. andSutton, M.A., “Strain-field Analysis Acquired Through Correlation of X-ray Radiographs of a Fiber-reinforced Composite Laminate,” EXPERIMENTAL MECHANICS,29,237–240 (1989).10.1007/BF02321382 ↗
13. Bay, B.K., “Texture Correlation: A Method for the Measurement of Detailed Strain Distributions Within Trabecular Bone,”J. Orthopaedic Res.,13,258–267 (1995).10.1002/jor.1100130214 ↗
14. Helm, J.D., McNeill, S.R., andSutton, M.A., “Improved Three-dimensional Image Correlation for Surface Displacement Measurement,”Opt. Eng.,35,1911–1920 (1996).10.1117/1.600624 ↗
15. Kahn-Jetter, Z.L. andChu, T.C., “Three-dimensional Displacement Measurements Using Digital Image Correlation and Photogrammic Analysis,” EXPERIMENTAL MECHANICS,30,10–16 (1990).10.1007/BF02322695 ↗
16. Durand, E.P. andRuegsegger, P., “Cancellous Bone Structure: Analysis of High-resolution Ct Images with the Run-length Method,”J. Computer Assisted Tomography,15,133–139 (1991).10.1097/00004728-199101000-00021 ↗
17. Elke, R.P.E., Cheal, E.J., Simmons, C., andPoss, R., “Three-dimensional Anatomy of the Cancellous Structures Within the Proximal Femur from Computed Tomography Data,”J. Orthopaedic Res.,13,513–523 (1995).10.1002/jor.1100130406 ↗
18. Feldkamp, L.A., Goldstein, S.A., Parfitt, A.M., Jesion, G., andKleerekoper, M., “The Direct Examination of Three-dimensional Bone Architecture In Vitro by Computed Tomography,”J. Bone Mineral Res.,4,3–11 (1989).10.1002/jbmr.5650040103 ↗
19. Flynn, M.J. andCody, D.D., “The Assessment of Vertebral Bone Macroarchitecture with X-ray Computed Tomography,”Calcified Tissue Int.,53,S170-S175 (1993).10.1007/BF01673430 ↗
20. Kuhn, J.L., Goldstein, S.A., Feldkamp, L.A., Goulet, R.W., andJesion, G., “Evaluation of a Microcomputed Tomography System to Study Trabecular Bone Structure,”J. Orthopaedic Res.,8,833–842 (1990).10.1002/jor.1100080608 ↗
21. Bart-Smith, H., Bastawros, A.F., Mumm, D.R., Evans, A.G., Sypeck, D.J., andWadley, H.N.G., “Compressive Deformation and Yielding Mechanisms in Cellular Al Alloys Determined Using X-ray Tomography and Surface Strain Mapping,”Acta Materialia,46,3583–3592 (1998).10.1016/S1359-6454(98)00025-1 ↗
22. Breunig, T.M., Stock, S.R., andBrown, R.C., “Simple Load Frame for In Situ Computed Tomography and X-ray Tomographic Microscopy,”Mat. Eval.,51,596–600 (1993).
23. Burch, S.F. andLawrence, P.F., “Recent Advances in Computerized X-ray Tomography Using Real-time Radiography Equipment,”Brit. J. NDT,34,129–133 (1992).
24. Deis, T.A. andLannutti, J.J., “X-ray Computed Tomography for Evaluation of Density Gradient Formation During the Compaction of Spray-dried Granules,”J. Am. Ceramic Soc.,81,1237–1247 (1998).10.1111/j.1151-2916.1998.tb02474.x ↗
25. Drake, S.G., “Improved Real-time X-ray Technology Widens the Horizons of Industrial Computer Tomography,”Brit. J. NDT,35,580–583 (1993).
26. Jasti, J.K., Jesion, G., andFeldkamp, L., “Microscopic Imaging of Porous Media with X-ray Computer Tomography,”SPE Formation Eval.,8,189–193 (1993).10.2118/20495-PA ↗
27. Kropas, C.V., Moran, T.J., andYancey, R.N., “Effect of Composition on Density Measurement by X-ray Computed Tomography,”Mat. Eval.,49,487–490 (1991).
28. Lambrineas, P., Davis, J.R., Suendermann, B., Wells, P., Thomson, K.R., Woodward, R.L., Egglestone, G.T., andChallis, K., “X-ray Computed Tomography Examination of Inshore Mine-hunter Hull Composite Material,”NDT&E Int.,24,207–213 (1991).10.1016/0963-8695(91)90269-9 ↗
29. Lavebratt, H., Ostman, E., Persson, S., andStenberg, B., “Application of Computed X-ray Tomography Scanning in the Study of Thermo-oxidative Degradation of Thick-walled Filled Natural Rubber Vulcanizates,”J. Appl. Polymer Sci.,44,83–94 (1992).10.1002/app.1992.070440108 ↗
30. London, B., Yancey, R.N., andSmith, J.A., “High-resolution X-ray Computed Tomography of Composite Materials,”Mat. Eval.,48,604–608 (1990).
31. Phillips, D.H. andLannutti, J.J., “Measuring Physical Density with X-ray Computed Tomography,”NDT&E Int.,30,339–350 (1997).10.1016/S0963-8695(97)00020-0 ↗
32. Watson, A.T. andMudra, J., “Characterization of Devonian Shales with X-ray Computed Tomography,”SPE Formation Eval.,9,209–212 (1994).10.2118/22943-PA ↗
33. Reimann, D.A., Hames, S.M., Flynn, M.J., andFyhrie, D.P., “A Cone Beam Computed Tomography System for True 3D Imaging of Specimens,”Appl. Radiation Isotopes,48, (10–12),1433–1436 (1997).10.1016/S0969-8043(97)00139-5 ↗
34. Feldkamp, L.A., Davis, L.C., andKress, J.W., “Practical Cone-beam Algorithm,”J. Opt. Soc. Am. A,1,612–619 (1984).10.1364/JOSAA.1.000612 ↗
35. Gill, P.E., Murray, W., andWright, M.H., Practical Optimization, Academic Press, London, 133–140 (1981).
36. Lancaster, P. andSalkauskas, K., Curve and Surface Fitting—An Introduction, Academic Press, London, 190 (1986).
37. Geers, M.G.D., De Borst, R., andBrekelmans, W.A.M., “Compuling Strain Fields from Discrete Displacement Fields in 2D-solids,”Int. J. Solids Struct.,33,4293–4307 (1996).10.1016/0020-7683(95)00240-5 ↗
38. Keaveny, T.M., Guo, X.E., Wachtel, E.F., McMahon, T.A., andHayes, W.C., “Trabecular Bone Exhibits Fully Linear Elastic Behavior and Yields at Low Strain,”J. Biomechanics,27,1127–1136 (1994).10.1016/0021-9290(94)90053-1 ↗