A Piezoelectric Technique for Evaluation of Crack Closure
Source abstract
Abstract
The ability of the piezoelectric materials to work as sensors and actuators was employed in a technique for monitoring the degree of crack closure and to detect the crack opening load. The technique is demonstrated through experiments with a cracked beam. It consists in exciting the specimen with a piezoelectric actuator and recording the electromechanical response of piezoelectric sensors placed near the crack mouth, while applying a bending moment to open the crack. The sensors in the neighborhood of the crack present a reduction in the amplitude response signal due to the progressive decrease of the dynamic strains near the crack, as the bending load causes the crack to open, reducing the contact between the surfaces of the fatigue crack and the load transmission through the contact area. The results show that the method has a high sensitivity to the state of crack closure, allowing for the direct determination of the crack opening load.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Health Monitoring Techniques · Ultrasonics and Acoustic Wave Propagation · Non-Destructive Testing Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (11)
Show source-provided references
1. Stoychev S, Kujawski D (2003) Methods for crack opening load and crack tip shielding determination: a review. Fatigue Fract Eng Mater Struct 2611:1053–1067(15)10.1046/j.1460-2695.2003.00691.x ↗
2. Nowell D (2007) Techniques for experimental measurement of fatigue crack closure. Appl Mech Mater 7–8:3–910.4028/www.scientific.net/AMM.7-8.3 ↗
3. Saka M, Akanda MAS (2004) Ultrasonic measurement of the crack depth and the crack opening stress intensity factor under a no load condition. J Nondestr Eval 232:49–63. doi: 10.1023/B:JONE.0000045220.19233.c310.1023/B:JONE.0000045220.19233.c3 ↗
4. Zhang W, Testa RB (1999) Closure effects on fatigue crack detection. J Eng Mech 12510:1125–1132. doi: 10.1061/(ASCE)0733-9399(1999)125:10(1125)10.1061/(ASCE)0733-9399(1999)125:10(1125) ↗
5. Morikawa SRK, Gama AL, Braga AMB, Correia RR (2005) Monitoring surface breaking defects with piezoelectric active systems. Exp Mech 451:89–95. doi: 10.1007/BF0242899410.1007/BF02428994 ↗
6. Rajic N (2000) In situ monitoring of crack growth in mild steel under closure conditions using a piezotransducer array. J Int Mater Syst Struct 119:696–70210.1106/4XU5-J58T-P7VU-UCYE ↗
7. Dimarogonas AD (1996) Vibration of cracked structures: a state of the art review. Eng Fract Mech 555:831–857. doi: 10.1016/0013-7944(94)00175-810.1016/0013-7944(94)00175-8 ↗
8. Sirohi J, Chopra I (2000) Fundamental understanding of piezoelectric strain sensors. J Int Mater Syst Struct 114:246–25710.1106/8BFB-GC8P-XQ47-YCQ0 ↗
9. Belova MV, Golyamina IP, Rastorguev DL (1988) Piezoelectric–polymer strain gauges. Instrum Exp Tech 316:1553–1557
10. Chondros TG, Dimarogonas AD, Yao J (2001) Vibration of a beam with a breathing crack. J Sound Vib 2391:57–67. doi: 10.1006/jsvi.2000.315610.1006/jsvi.2000.3156 ↗
11. Newman JCA (1984) A crack opening stress equation for fatigue crack growth. Int J Fract 244:R131–R13510.1007/BF00020751 ↗