Abstract
Digital Image Correlation (DIC) is a well-established, non-contact diagnostic technique used to measure shape, displacement and strain of a solid specimen subjected to loading or deformation. However, measurements using standard DIC can have significant errors or be completely infeasible in challenging experiments, such as explosive, combustion, or fluid-structure interaction applications, where beam-steering due to index of refraction variation biases measurements or where the sample is engulfed in flames or soot. To address these challenges, we propose using X-ray imaging instead of visible light imaging for stereo-DIC, since refraction of X-rays is negligible in many situations, and X-rays can penetrate occluding material. Two methods of creating an appropriate pattern for X-ray DIC are presented, both based on adding a dense material in a random speckle pattern on top of a less-dense specimen. A standard dot-calibration target is adapted for X-ray imaging, allowing the common bundle-adjustment calibration process in commercial stereo-DIC software to be used. High-quality X-ray images with sufficient signal-to-noise ratios for DIC are obtained for aluminum specimens with thickness up to 22.2 mm, with a speckle pattern thickness of only 80 μm of tantalum. The accuracy and precision of X-ray DIC measurements are verified through simultaneous optical and X-ray stereo-DIC measurements during rigid in-plane and out-of-plane translations, where errors in the X-ray DIC displacements were approximately 2–10 μm for applied displacements up to 20 mm. Finally, a vast reduction in measurement error—5–20 times reduction of displacement error and 2–3 times reduction of strain error—is demonstrated, by comparing X-ray and optical DIC when a hot plate induced a heterogeneous index of refraction field in the air between the specimen and the imaging systems. Collectively, these results show the feasibility of using X-ray-based stereo-DIC for non-contact measurements in exacting experimental conditions, where optical DIC cannot be used.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Optical measurement and interference techniques · Advanced X-ray Imaging Techniques · Advanced Measurement and Metrology Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. Sutton MA, Orteu JJ, Schreier H (2009) Image correlation for shape, motion, and deformation measurements: basic concepts, theory, and applications. Springer US
2. Sutton M A, Wolters W J, Peters W H, Ranson W F, McNeill S R (1983) Determination of displacements using an improved digital correlation method. Image Vision Comput 1(3):133–13910.1016/0262-8856(83)90064-1 ↗
3. International Digital Image Correlation Society, Jones EMC, Iadicola MA (2018) A good practices guide for digital image correlation, 1 edn. https://doi.org/10.32720/idics/gpg.ed110.32720/idics/gpg.ed1 ↗
4. Smith CM, Hoehler MS (2018) Imaging through fire using narrow-spectrum illumination. Fire Technol 54:1705–172310.1007/s10694-018-0756-5 ↗
5. Jones EMC, Reu P (2018) Distortion of digital image correlation (DIC) displacements and strains from heat waves. Exp Mech 58:1133–115910.1007/s11340-017-0354-3 ↗
6. Abotula S, Heeder N, Chona R, Shukla A (2014) Dynamic thermo-mechanical response of Hastelloy X to shock wave loading. Exp Mech 54:279–29110.1007/s11340-013-9796-4 ↗
7. Pan B, Wu D, Wang Z, Xia Y (2011) High-temperature digital image correlation method for full-field deformation measurement at 1200c. Meas Sci Technol 22:1–11
8. Gupta S, Parameswaran V, Sutton M A, Shukla A (2014) Study of dynamic underwater implosion mechanics using digital image correlation. Proc R Soc A 470:1–1710.1098/rspa.2014.0576 ↗
9. Reu P, Miller TJ (2008) The application of high-speed digital image correlation. J Strain Anal 43:673–68810.1243/03093247JSA414 ↗
10. Pankow M, Justusson B, Waas A M (2010) Three-dimensional digital image correlation technique using single high-speed camera for measureming large out-of-plane displacements at high framing rates. Appl Opt 49 (17):3418–342710.1364/AO.49.003418 ↗
11. Lynch KP, Jones EMC, Wagner JL (2018) Simultaneous PSP and surface deformation measurements for fluid-structure interactions in a shock tube. In: 2018 fluid dynamics conference, AIAA AVIATION forum. AIAA, pp 2018–387010.2514/6.2018-3870 ↗
12. Giovannetti LM, Banks J, Turnock SR, Boyd SW (2017) Uncertainty assessment of coupled digital image correlation and particle image velocimetry for fluid-structure interaction wind tunnel experiments. J Fluid Struct 68:125–14010.1016/j.jfluidstructs.2016.09.002 ↗
13. Spottswood SM, Beberniss TJ, Eason TG, Perez RA, Donbar JM, Ehrhardt DA, Riley ZB (2018) Exploring the response of a thin, flexible panel to shock-turbulent boundary-layer interactions. J Sound Vib. https://doi.org/10.1016/j.jsv.2018.11.03510.1016/j.jsv.2018.11.035 ↗
14. Henke BL, Guillikson EM, Davis JC (1993) X-ray interactions: photoabsorption, scattering, transmission, and reflection at E = 50–30,000 eV, Z = 1–92. Atom Data Nucl Data 54:181–34210.1006/adnd.1993.1013 ↗
15. Thompson A, Attwood D, Guillikson EM, Howells M, Kim K-J, Kirz J, Kortright J, Lindau I, Liu Y, Pianetta P, Robinson A, Scofield J, Underwood J, Williams G, Winick H (2009) X-ray data booklet. Available online: http://xdb.lbl.gov/ . Accessed 2018-05-10. National Lawence Berkeley National Laboratory
16. Chantler CT, Olsen K, Dragoset RA, Chang J, Kishore AR, Kotochigova SA, Zucker DS (2000) X-ray form factor, attenuation and scattering tables, 2005. Version 2.1. Available online: http://physics.nist.gov/ffast . Accessed 2018-05-10. National Institute of Standards and Technology, Gaithersburg, MD. Originally published as Chantler, C.T., J. Phys. Chem. Ref. Data 29(4), 597-1048 (2000)
17. and Chantler, C.T., J. Phys. Chem. Ref. Data 24, 71-643 (1995)
18. Hubbell JH, Seltzer SM (2018) X-ray mass attenuation coefficients. NIST Standard Reference Database 126. https://www.nist.gov/pml/x-ray-mass-attenuation-coefficients Accessed Nov 2018
19. Russell SS, Sutton MA (1989) Strain-field analysis acquired through correlation of X-ray radiographs of a fiber-reinforced composite laminate. Exp Mech 29(2):237–24010.1007/BF02321382 ↗
20. Synnergren P, Goldrein HT, Proud WG (1999) Application of digital speckle photography to flash x-ray studies of internal deformation fields in impact experiments. Appl Opt 38(19):4030–403610.1364/AO.38.004030 ↗
21. Prentice HJ, Proud WG, Walley SM, Field JE (2010) The use of digital speckle radiography to study the ballistic deformation of a polymer bounded sugar (an explosive simulant). Int J Impact Eng 37:1113–112010.1016/j.ijimpeng.2010.05.003 ↗
22. Grantham SG, Goldrein HT, Proud WG, Field JE (2003) Digital speckle radiography—a new ballistic measurement technique. Imaging Sci J 51(3):175–18610.1080/13682199.2003.11784423 ↗
23. Rae P J, Williamson D M, Addiss J (2011) A comparison of 3 digital image correlation techniques on necessarily suboptimal random patterns recorded by x-ray. Exp Mech 51(4):467–47710.1007/s11340-010-9444-1 ↗
24. Louis L, Wong T-F, Baud P (2007) Imaging strain localization by X-ray radiography and digital image correlation: deformation bands in Rothbach sandstone. J Struct Geol 29:129–14010.1016/j.jsg.2006.07.015 ↗
25. Bay BK (1995) Texture correlation: a method for the measurement of detailed strain distributions within trabecular bone. J Orthop Res 13:258–26710.1002/jor.1100130214 ↗
26. Synnergren P, Goldrein HT (1999) Dynamic measurements of internal three-dimensional displacement fields with digital speckle photography and flash x-rays. Appl Opt 38(28):5956–596110.1364/AO.38.005956 ↗
27. Bay BK, Smith TS, Fyhrie DP, Saad M (1999) Digital volume correlation: three-dimensional strain mapping using x-ray tomography. Exp Mech 39(3):217–22610.1007/BF02323555 ↗
28. Bay BK (2008) Methods and applications of digital volume correlation. J Strain Anal 43:745–76010.1243/03093247JSA436 ↗
29. Croom B P, Jin H, Mills B, Li X (2019) Effect of fragile speckle patterns on accuracy of digital volume correlation. Exp Mech. https://doi.org/10.1007/s11340-019-00512-410.1007/s11340-019-00512-4 ↗
30. An introduction to thermal spray. BRO-0005.6, 2016. Available online: https://www.oerlikon.com/metco/en/products-services/coating-equipment/thermal-spray/processes/ . Accessed 2018-05-10. Oerlikon Metco
31. Davis JR (2004) Handbook of thermal spray technology. ASM International
32. Reu P (2014) All about speckles: speckle size measurement. Exp Tech 38(6):1–210.1111/ext.12110 ↗
33. Miller TJ, Quintana EC (2013) Stereo x-ray system calibration for three-dimensional measurements. Available online: https://prod.sandia.gov/techlib/auth-required.cgi/2013/132097c.pdf . Accessed 2018-05-10
34. Li N, Sutton M A, Li X, Schreier H W (2008) Full-field thermal deformation measurements in a scanning electron microscope by 2d digital image correlation. Exp Mech 48(5):635–64610.1007/s11340-007-9107-z ↗
35. Xu Z-H, Li X-D, Sutton M A, Li N (2008) Drift and spatial distortion elimination in atomic force microscopy images by the digital image correlation technique. J Strain Anal Eng 43(8):729–74310.1243/03093247JSA400 ↗
36. Zhu T, Sutton M A, Li N, Orteu J J, Cornille N, Li X, Reynolds A P (2011) Quantitative stereovision in a scanning electron microscope. Exp Mech 51(1):97–10910.1007/s11340-010-9378-7 ↗
37. Maraghechi S, Hoefnagels J P M, Peerlings R H J, Rokoš O, Geers M G D (2019) Correction of scanning electron microscope imaging artifacts in a novel digital image correlation framework. Exp Mech 59 (4):489–51610.1007/s11340-018-00469-w ↗