journal article·2003-03

A NEW NONCONTACT METAL-CERAMIC FLUID ACOUSTIC EMISSION SENSOR

Z. Wang, X. Wang, F. Li

Experimental Techniques· Volume 27· Issue 2
Publisher page

Abstract

The results of performance tests of the newly developed fluid AE sensors showed that the sensors have a wide frequency range, have high sensitivity to various AE signals coming from the three cutting zones, and can be used both in tool wear monitoring and in tool breakage identification. It is the successful development of the new types of high sensitivity non-contact fluid AE sensors that solves the difficult problem of tool wear monitoring with low energy AE signal, and also lays a foundation for tool wear on-line monitoring by using the no-contact fluid sensors.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Acoustic Wave Resonator Technologies · Gas Sensing Nanomaterials and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (6)

Show source-provided references
1. Kramer B.M. · Annals of the CIRP · 1983 · 32 · 56310.1016/S0007-8506(07)60184-X ↗
2. Diei E.N. · Journal of Engineering for Industry · 1987 · 109 · 9210.1115/1.3187114 ↗
3. Dornfeld D.A. · Annal of CIRP · 1992 · 41 · 9310.1016/S0007-8506(07)61160-3 ↗
4. Blum T. · Transactions of the ASME, Journal of Engineering for Industry · 1990 · 112 · 20310.1115/1.2899576 ↗
5. 5. D.V. Hutton , A Noncontact Acoustic Emission Sensing System for Rotating-cutting Machining Processes , EXPERIMENTAL TECHNIQUES, 1991 : 40 -44 .10.1111/j.1747-1567.1991.tb01228.x ↗
6. Zhi-fu J. · Sensor Techniques · 1997 · 16 · 22