Plasticity induced crack closure in Middle‐Crack Tension specimen: numerical versus experimental
Source abstract
Abstract
ABSTRACT Numerical studies played a major role in the current understanding of plasticity induced crack closure (PICC), however it is well known that the numerical models simplify the reality by considering discrete crack propagations, relatively high fatigue crack growth rates, sharp cracks and that propagation occurs at a well‐defined load. The objective of this paper is to find if despite these limitations, the numerical predictions of PICC are close to the experimental results. Experimental work was developed to obtain crack opening values in 1‐mm‐thick middle‐tension (M(T)) specimens of AA6016‐T4 aluminium alloy. The opening level was determined from remote compliance data captured by a pin microgauge placed at the centre of the specimen. A numerical model was developed and optimized replicating the experimental test in terms of sample geometry, loading parameters, material behaviour and crack opening measurement technique. The adoption, in the numerical analysis, of a remote measurement technique for determining PICC was found to be robust and adequate for mesh refinement studies. A good agreement was found between experimental and numerical results.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Fatigue and fracture mechanics · Numerical methods in engineering · Non-Destructive Testing Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (46)
Show source-provided references
1. Fatigue crack growth affected by metal fragments wedged between opening‐closing crack surfaces
2. 10.1016/0013-7944(70)90028-710.1016/0013-7944(70)90028-7 ↗
3. The significance of fatigue crack closure under cyclic tension. Damage tolerance in aircraft structures
4. 10.1016/S0013-7944(02)00119-410.1016/S0013-7944(02)00119-4 ↗
5. 10.1016/j.tws.2004.11.00110.1016/j.tws.2004.11.001 ↗
6. 10.1520/STP23283S10.1520/STP23283S ↗
7. 10.1046/j.1460-2695.2003.00691.x10.1046/j.1460-2695.2003.00691.x ↗
8. ASTM E647‐95 · 1995 · 578
9. 10.1007/BF0001626110.1007/BF00016261 ↗
10. 10.1520/STP27226S10.1520/STP27226S ↗
11. Systematic assessment and validation of compliance‐based crack closure measurements in fatigue10.1016/S0921-5093(00)00758-9 ↗
12. 10.1016/j.ijfatigue.2004.04.00410.1016/j.ijfatigue.2004.04.004 ↗
13. Song J. H.andKang J. Y.(2002)Quantitative evaluation of Kopdetermination and ΔKeffestimation methods. In:Fatigue 2002: Proceedings of the Eighth International Fatigue Congress Stockholm(Edited byA. F.Blom) pp.2345–2352.
14. A method for determining crack opening load from load–displacement data. Mech Fatigue Crack Closure
15. 10.1111/j.1460-2695.1995.tb00916.x10.1111/j.1460-2695.1995.tb00916.x ↗
16. Kikukawa M. Jono M.andTanaka K.(1976)Fatigue crack closure behaviour at low stress intensity factor level. In:Proceedings of the Second International Conference Mechanical Behaviour of Materials(ICM‐2) Special Vol. pp.254–277.
17. 10.1016/0013-7944(86)90150-510.1016/0013-7944(86)90150-5 ↗
18. 10.1111/j.1460-2695.1987.tb00485.x10.1111/j.1460-2695.1987.tb00485.x ↗
19. 10.1016/0013-7944(91)90027-X10.1016/0013-7944(91)90027-X ↗
20. 10.1016/S0013-7944(96)00104-X10.1016/S0013-7944(96)00104-X ↗
21. 10.1111/j.1460-2695.1997.tb00285.x10.1111/j.1460-2695.1997.tb00285.x ↗
22. 10.1111/j.1460-2695.1997.tb01540.x10.1111/j.1460-2695.1997.tb01540.x ↗
23. 10.1016/j.ijfatigue.2004.11.00810.1016/j.ijfatigue.2004.11.008 ↗
24. 10.1016/S0013-7944(00)00014-X10.1016/S0013-7944(00)00014-X ↗
25. 10.1016/j.engfracmech.2007.02.02010.1016/j.engfracmech.2007.02.020 ↗
26. 10.1016/j.engfracmech.2008.04.02410.1016/j.engfracmech.2008.04.024 ↗
27. 10.1046/j.1460-2695.2001.00383.x10.1046/j.1460-2695.2001.00383.x ↗
28. 10.1016/j.commatsci.2008.03.02810.1016/j.commatsci.2008.03.028 ↗
29. 10.1016/S0924-0136(99)00345-310.1016/S0924-0136(99)00345-3 ↗
30. 10.1002/nme.84510.1002/nme.845 ↗
31. 10.1016/j.ijplas.2006.07.00310.1016/j.ijplas.2006.07.003 ↗
32. Alves J.L.andMenezes L. F.(2001)Application of tri‐linear and tri‐quadratic 3‐D solid FE in sheet metal forming process simulation. In:Proceedings of theNUMIFORM 2001(Edited byK.Mori) Japan pp.639–644.
33. 10.1016/j.finel.2004.01.00910.1016/j.finel.2004.01.009 ↗
34. 10.1016/j.engfracmech.2007.12.00910.1016/j.engfracmech.2007.12.009 ↗
35. 10.1111/j.1460-2695.2008.01216.x10.1111/j.1460-2695.2008.01216.x ↗
36. 10.1016/0013-7944(89)90027-110.1016/0013-7944(89)90027-1 ↗
37. 10.1016/S0013-7944(02)00168-610.1016/S0013-7944(02)00168-6 ↗
38. 10.1016/S0013-7944(03)00003-110.1016/S0013-7944(03)00003-1 ↗
39. 10.1016/j.engfracmech.2004.04.00210.1016/j.engfracmech.2004.04.002 ↗
40. 10.1016/S0013-7944(99)00040-510.1016/S0013-7944(99)00040-5 ↗
41. 10.1016/j.engfracmech.2007.12.01210.1016/j.engfracmech.2007.12.012 ↗
42. 10.1023/A:101868493207110.1023/A:1018684932071 ↗
43. Determination of elastic properties by resonant technique: a sensitivity analysis10.1520/JTE101041 ↗
44. 10.1007/BF0266736910.1007/BF02667369 ↗
45. 10.1016/0013-7944(79)90004-310.1016/0013-7944(79)90004-3 ↗
46. 10.1016/0013-7944(81)90108-910.1016/0013-7944(81)90108-9 ↗