Purpose With the development of new power systems toward high proportion of renewable energies and high proportion of power electronic equipment, grid-forming (GFM) inverters play an important role in new power systems due to its well active support capabilities for voltage and inertia. The fault ride-through ability of GFM inverter is the foundation for guaranteeing the safety and stability of power systems. However, during fault, the large disturbances may cause the GFM inverter lose stable equilibrium point (SEP) and induce transient instability issues. To address this challenge, this paper aims to propose a transient stability enhancement strategy of GFM inverter based on adaptive q-axis voltage feedback control. Design/methodology/approach First, a transient stability analysis model of GFM inverter while considering the current limitation and q-axis voltage feedback is established, and impacts of q-axis voltage feedback on the transient stability of GFM inverter under the gird voltage sag is revealed. Inspired by this, an adaptive q-axis voltage feedback control is proposed to improve the transient stability of GFM inverter. Findings According to the voltage sag degree, the expression of adaptive q-axis voltage feedback coefficient is designed, which can adaptively change the equivalent active power reference to guarantee the existence of the SEP in the system whatever the current limitation is triggered or not. Also, since the q-axis voltage feedback coefficient is equal to zero under the normal operation, it has no impact on GFM inverter. Finally, the correctness and effectiveness of the proposed strategy are verified by the hardware-in-the-loop simulation experimental platform. Originality/value A transient stability analysis model of GFM inverter system while considering the current limitation and q-axis voltage feedback branch is established. Under the condition of short circuit fault, the influences of q-axis voltage feedback coefficient on the system’s transient stability are revealed after triggering current limitation. An adaptive coefficient of q-axis voltage feedback in GFM inverter is designed, which can adaptively change the equivalent active power reference to guarantee the existence of the SEP in the system under different grid voltage dips, and it has no effects on normal operation of GFM inverter.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Microgrid Control and Optimization · Wind Turbine Control Systems · HVDC Systems and Fault Protection

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

State Grid Hubei Electric Power Co Ltd Electric Power Research Institute , Wuhan, ; Hubei Key Laboratory of Regional New Power Systems and Rural Energy System Configuration, Wuhan, China and Hubei Engineering Research Center of the Construction and Operation Control Technology of New Power Systems, Wuhan, China

State Grid Hubei Electric Power Co Ltd Electric Power Research Institute , Wuhan, , and Hubei Key Laboratory of Regional New Power Systems and Rural Energy System Configuration, Wuhan, China

Sichuan University College of Electrical Engineering, , Chengdu,

Funding

Science and technology project of State Grid Hubei Electric Power Co., Ltd

References (30)

Show source-provided references
1. Grid-impedance estimation in high-frequency range with a single signal injection using time–frequency distribution10.1049/iet-smt.2018.5617 ↗
2. Enhanced transient angle stability control of grid-forming converter based on virtual synchronous generator10.1109/TIE.2021.3114723 ↗
3. Large-signal stability of grid-forming and grid-following controls in voltage source converter: a comparative study10.1109/TPEL.2020.3047480 ↗
4. Generic PLL-based grid-forming control
5. Transient stability analysis and control design of droop-controlled voltage source converters considering current limitation10.1109/TSG.2017.2749259 ↗
6. Coupling characteristic analysis and synchronization stability control for multi-paralleled VSCs system under symmetric faults10.1016/j.ijepes.2023.109134 ↗
7. Modeling and stability analysis of multi grid-forming converters with connected to low-impedance grid10.1109/TPWRD.2025.3579482 ↗
8. Analysis and improvement of large-disturbance stability for grid-connected VSG based on output impedance optimization10.1109/TPEL.2022.3153563 ↗
9. Revisiting grid-forming and grid-following inverters: a duality theory10.1109/TPWRS.2022.3151851 ↗
10. A current limiting strategy with parallel virtual impedance for three-phase three-leg inverter under asymmetrical short-circuit fault to improve the controllable capability of fault currents10.1109/TPEL.2018.2879191 ↗
11. Optimal parameters and placement of hybrid energy storage systems for frequency stability improvement10.23919/PCMP.2023.000259 ↗
12. A current limiting method for single-loop voltage-magnitude controlled grid-forming converters during symmetrical faults10.1109/TPEL.2021.3122744 ↗
13. Physical insight into hybrid-synchronization-controlled grid-forming inverters under large disturbances10.1109/TPEL.2022.3168902 ↗
14. An online event-based grid impedance estimation technique using grid-connected inverters10.1109/TPEL.2020.3029872 ↗
15. Online grid impedance estimation-based adaptive control of virtual synchronous generators considering strong and weak grid conditions10.1109/TSTE.2022.3223976 ↗
16. Current limiting algorithms and transient stability analysis of grid-forming VSCs10.1016/j.epsr.2020.106726 ↗
17. Impacts of current limiting on the transient stability of the virtual synchronous generator10.1109/TPEL.2022.3208800 ↗
18. Characteristics and restraining method of fast transient inrush fault currents in synchronverters10.1109/TIE.2017.2652362 ↗
19. A two-stage simultaneous control scheme for the transient angle stability of vsg considering current limitation and voltage support10.1109/TPWRS.2021.3121474 ↗
20. A control strategy for a grid-connected virtual synchronous generator with virtual impedance10.1016/j.egyr.2022.10.381 ↗
21. Grid-current-sensorless control of grid-forming inverter with LCL filter10.1016/j.ijepes.2023.109002 ↗
22. An improved equal area criterion for transient stability analysis of converter-based microgrid considering nonlinear damping effect10.1109/TPEL.2022.3164687 ↗
23. Current limiting control with enhanced dynamics of grid-forming converters during fault conditions10.1109/JESTPE.2019.2931477 ↗
24. Transient synchronization stability of grid-forming converter during grid fault considering transient switched operation mode10.1109/TSTE.2023.3236950 ↗
25. Grid impedance detection based on complex coefficient filter and full-order capacitor current observer for three-phase grid-connected inverters10.1109/TPEL.2022.3217126 ↗
26. Transient synchronization stability analysis of PLL-based VSC using Lyapunov’s direct method10.1016/j.ijepes.2022.108135 ↗
27. Grid-synchronization stability of converter-based resources—an overview10.1109/OJIA.2020.3020392 ↗
28. Design-oriented transient stability analysis of PLL-synchronized voltage-source converters10.1109/TPEL.2019.2937942 ↗
29. Transient stability of voltage-source converters with grid-forming control: a design-oriented study10.1109/JESTPE.2019.2946310 ↗
30. An overview of assessment methods for synchronization stability of grid-connected converters under severe symmetrical grid faults10.1109/TPEL.2019.2892142 ↗