journal article·2020-09

Reversible microfluidic measurement with zinc tetraphenylporphyrin aiming at slipping NH 3 detection

Hao Zhou, Qi Yin, Zheng Yang, Yilin Song

Micro & Nano Letters· Volume 15· Issue 11
Publisher page

Abstract

A microfluidic chip that can realise reversible and highly selective NH 3 detection by separating NH 3 from the complex environment is fabricated for slipping NH 3 detection. The microfluidic chip consisting of the reaction unit, the gas‐diffusion unit and detection unit applied the immobilised zinc tetraphenylporphyrin as the indicating material. The continuous spectrum change showed the light intensity decreased in the green range (500–550 nm). Based on the analysis of the spectrum change at 528 nm, a one‐to‐one relationship between the spectrum change and concentration was revealed. The reversibility of the detection process makes the detection advantageous. Also, the rapidity of the proposed method is proved by the time responses of the indicating and recovering processes. According to the 40 tests conducted for various concentrations, it was concluded that the results are stable and the entire system is reliable.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Analytical Chemistry and Sensors · Advanced Chemical Sensor Technologies · Gas Sensing Nanomaterials and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

State Key Laboratory of Clean Energy Utilization Zhejiang University Hangzhou 310027 People's Republic of China

References (39)

Show source-provided references
1. 10.1016/j.snb.2004.11.05410.1016/j.snb.2004.11.054 ↗
2. 10.1016/j.fuproc.2016.05.01610.1016/j.fuproc.2016.05.016 ↗
3. 10.1016/j.fuel.2017.05.08110.1016/j.fuel.2017.05.081 ↗
4. 10.1016/j.flowmeasinst.2015.06.02510.1016/j.flowmeasinst.2015.06.025 ↗
5. 10.1007/s00604‐006‐0496‐y10.1007/s00604‐006‐0496‐y ↗
6. 10.1007/s00604020006810.1007/s006040200068 ↗
7. 10.1364/AO.40.00438710.1364/AO.40.004387 ↗
8. 10.1007/s00340‐015‐6073‐510.1007/s00340‐015‐6073‐5 ↗
9. 10.1364/OE.19.02310410.1364/OE.19.023104 ↗
10. 10.1016/j.apcatb.2005.12.00310.1016/j.apcatb.2005.12.003 ↗
11. 10.1016/j.jcat.2015.06.01610.1016/j.jcat.2015.06.016 ↗
12. 10.1007/s00604‐016‐1863‐y10.1007/s00604‐016‐1863‐y ↗
13. 10.1007/s00604‐014‐1410‐710.1007/s00604‐014‐1410‐7 ↗
14. 10.1016/0925‐4005(90)80209‐I10.1016/0925‐4005(90)80209‐I ↗
15. 10.1109/JSEN.2006.87402010.1109/JSEN.2006.874020 ↗
16. 10.1039/C4RA09568E10.1039/C4RA09568E ↗
17. 10.1039/C3RA45809A10.1039/C3RA45809A ↗
18. 10.1016/j.snb.2013.10.12010.1016/j.snb.2013.10.120 ↗
19. 10.1016/S0925‐4005(01)00573‐110.1016/S0925‐4005(01)00573‐1 ↗
20. 10.1021/ac303673410.1021/ac3036734 ↗
21. 10.1364/AO.51.00376810.1364/AO.51.003768 ↗
22. 10.1007/s00542‐011‐1382‐z10.1007/s00542‐011‐1382‐z ↗
23. 10.1021/ac100728310.1021/ac1007283 ↗
24. 10.1016/S0003‐2670(96)00269‐310.1016/S0003‐2670(96)00269‐3 ↗
25. 10.1021/acs.chemrev.6b0036110.1021/acs.chemrev.6b00361 ↗
26. 10.3390/s15051111810.3390/s150511118 ↗
27. 10.1002/elan.20110055210.1002/elan.201100552 ↗
28. 10.1039/C5TA02491A10.1039/C5TA02491A ↗
29. 10.1039/ac996330039310.1039/ac9963300393 ↗
30. 10.1016/S0925‐4005(03)00047‐910.1016/S0925‐4005(03)00047‐9 ↗
31. 10.1016/j.snb.2014.06.06010.1016/j.snb.2014.06.060 ↗
32. 10.1016/j.bios.2014.09.00610.1016/j.bios.2014.09.006 ↗
33. 10.1007/s00216‐020‐02577‐w10.1007/s00216‐020‐02577‐w ↗
34. 10.1016/j.aca.2019.05.05010.1016/j.aca.2019.05.050 ↗
35. 10.1039/C9LC01045A10.1039/C9LC01045A ↗
36. 10.1016/j.talanta.2019.03.04310.1016/j.talanta.2019.03.043 ↗
37. Functional film coated optical micro/nanofibers for high‐performance gas sensing10.1109/JSEN.2019.2924596 ↗
38. 10.1016/j.flowmeasinst.2018.02.01310.1016/j.flowmeasinst.2018.02.013 ↗
39. 10.1021/acs.analchem.6b0214010.1021/acs.analchem.6b02140 ↗